{"title":"Optic Nerve Sheath Diameter Estimation to Detect Increased Intracranial Pressure in Traumatic Brain Injury patients at a Level I Trauma Center in Eastern India.","authors":"Abdul Hakeem, Majid Anwer, Abdul Vakil Khan, Harendra Kumar, Venkatesh Karthikeyan, Rachith Sridhar, Anil Kumar, Anurag Kumar, Subhash Kumar","doi":"10.13004/kjnt.2025.21.e15","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the diagnostic accuracy of optic nerve sheath diameter (ONSD) measured by ultrasound as a non-invasive marker for detecting elevated intracranial pressure (ICP) in patients with traumatic brain injury (TBI), based on clinical and radiological findings.</p><p><strong>Methods: </strong>This diagnostic accuracy study included 180 adult patients with isolated TBI admitted to a Level I Trauma Centre in Eastern India. ONSD was measured bilaterally using a 7.5 MHz linear ultrasound probe, 3 mm posterior to the globe. Clinical and radiological parameters were recorded, and increased ICP was determined based on a predefined clinical signs and computed tomography findings. Statistical analysis included logistic regression and receiver operating characteristic (ROC) curve analysis using Jamovi software.</p><p><strong>Results: </strong>The mean ONSD was significantly higher in patients with increased ICP (5.36±0.56 mm) compared to those without (4.13±0.34 mm, <i>p</i><0.001). ROC analysis showed excellent diagnostic performance (area under the curve: 0.942), with sensitivity and specificity of 93.2% and 81.8%, respectively, at a cut-off value of 5.0 mm. The positive predictive value was 74.0%, and the negative predictive value was 99.0%. Increased ONSD was associated with TBI severity and poor Glasgow Outcome Scale scores at 3 months.</p><p><strong>Conclusion: </strong>Ultrasound-measured ONSD is a sensitive, non-invasive bedside tool for detecting increased ICP in TBI patients, particularly useful in resource-limited settings.</p>","PeriodicalId":36879,"journal":{"name":"Korean Journal of Neurotrauma","volume":"21 2","pages":"93-101"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12062819/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Neurotrauma","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13004/kjnt.2025.21.e15","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the diagnostic accuracy of optic nerve sheath diameter (ONSD) measured by ultrasound as a non-invasive marker for detecting elevated intracranial pressure (ICP) in patients with traumatic brain injury (TBI), based on clinical and radiological findings.

Methods: This diagnostic accuracy study included 180 adult patients with isolated TBI admitted to a Level I Trauma Centre in Eastern India. ONSD was measured bilaterally using a 7.5 MHz linear ultrasound probe, 3 mm posterior to the globe. Clinical and radiological parameters were recorded, and increased ICP was determined based on a predefined clinical signs and computed tomography findings. Statistical analysis included logistic regression and receiver operating characteristic (ROC) curve analysis using Jamovi software.

Results: The mean ONSD was significantly higher in patients with increased ICP (5.36±0.56 mm) compared to those without (4.13±0.34 mm, p<0.001). ROC analysis showed excellent diagnostic performance (area under the curve: 0.942), with sensitivity and specificity of 93.2% and 81.8%, respectively, at a cut-off value of 5.0 mm. The positive predictive value was 74.0%, and the negative predictive value was 99.0%. Increased ONSD was associated with TBI severity and poor Glasgow Outcome Scale scores at 3 months.

Conclusion: Ultrasound-measured ONSD is a sensitive, non-invasive bedside tool for detecting increased ICP in TBI patients, particularly useful in resource-limited settings.

Abstract Image

Abstract Image

Abstract Image

在印度东部的一级创伤中心,视神经鞘直径估计检测颅内压增加的外伤性脑损伤患者。
目的:结合临床和影像学表现,评价超声测量视神经鞘直径(ONSD)作为检测外伤性脑损伤(TBI)患者颅内压升高的无创标志物的诊断准确性。方法:这项诊断准确性研究纳入了印度东部一级创伤中心收治的180例孤立性TBI成年患者。使用7.5 MHz线性超声探头测量双侧ONSD,探头距球体后3 mm。记录临床和放射学参数,并根据预先确定的临床体征和计算机断层扫描结果确定颅内压升高。统计分析采用logistic回归和受试者工作特征(ROC)曲线分析,采用Jamovi软件。结果:颅内压增高患者的平均ONSD(5.36±0.56 mm)明显高于非颅内压增高患者(4.13±0.34 mm)。结论:超声测量的ONSD是一种敏感、无创的床边工具,可用于检测颅内压增高,在资源有限的情况下特别有用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
41
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信