Non-Invasive Measurement of Hemodynamic Parameters via Whole-Body Impedance Cardiography Among Hospitalized Heart Failure Patients: An Effective Alternative to Invasive Right Heart Catheterization?
Felix Ausbuettel, Sabah Khwamurad, Murad Haj Abdo, Sebastian Kerber, Karin Nentwich, Martina Hautmann, Sebastian Barth
{"title":"Non-Invasive Measurement of Hemodynamic Parameters via Whole-Body Impedance Cardiography Among Hospitalized Heart Failure Patients: An Effective Alternative to Invasive Right Heart Catheterization?","authors":"Felix Ausbuettel, Sabah Khwamurad, Murad Haj Abdo, Sebastian Kerber, Karin Nentwich, Martina Hautmann, Sebastian Barth","doi":"10.3390/jcdd12040128","DOIUrl":null,"url":null,"abstract":"<p><p>(1) Background: The measurement of hemodynamic parameters has proven to be crucial in the treatment of hospitalized heart failure patients, necessitating invasive measurement by right heart catheterization (RHC). The reliability of whole-body impedance cardiography (ICG) among this cohort has not been investigated to date; (2) Methods: The RHC and whole-body ICG examinations measured cardiac output (CO), the cardiac index (CI), total peripheral resistance (TPR), and pulmonary vascular resistance (PVR). To assess the accuracy of the whole-body ICG measurement, bias and precision were calculated as the mean difference and the twofold standard deviation between the average values of measurements; (3) Results: A total of 203 patients were analyzed. No significant bias was observed between the non-invasive CO and CI measurements when compared with the RHC measurements (-0.14 ± 2.56 L/min, <i>p</i> = 0.1; -0.09 ± 1.3 L/min/m<sup>2</sup>, <i>p</i> = 0.06), but a significant bias occurred in the measurement of non-invasive TPR and non-invasive PVR (-1243 ± 3510 dyn × s<sup>-1</sup> × cm<sup>-5</sup>, <i>p</i> = 0.001; -121 ± 504 dyn × s<sup>-1</sup> × cm<sup>-5</sup>, <i>p</i> < 0.001); (4) Conclusions: CO and CI can be measured with whole-body ICG among hospitalized CHF patients with acceptable accuracy. The reliability of measuring TPR and PVR should be further investigated.</p>","PeriodicalId":15197,"journal":{"name":"Journal of Cardiovascular Development and Disease","volume":"12 4","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12027845/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Development and Disease","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/jcdd12040128","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
(1) Background: The measurement of hemodynamic parameters has proven to be crucial in the treatment of hospitalized heart failure patients, necessitating invasive measurement by right heart catheterization (RHC). The reliability of whole-body impedance cardiography (ICG) among this cohort has not been investigated to date; (2) Methods: The RHC and whole-body ICG examinations measured cardiac output (CO), the cardiac index (CI), total peripheral resistance (TPR), and pulmonary vascular resistance (PVR). To assess the accuracy of the whole-body ICG measurement, bias and precision were calculated as the mean difference and the twofold standard deviation between the average values of measurements; (3) Results: A total of 203 patients were analyzed. No significant bias was observed between the non-invasive CO and CI measurements when compared with the RHC measurements (-0.14 ± 2.56 L/min, p = 0.1; -0.09 ± 1.3 L/min/m2, p = 0.06), but a significant bias occurred in the measurement of non-invasive TPR and non-invasive PVR (-1243 ± 3510 dyn × s-1 × cm-5, p = 0.001; -121 ± 504 dyn × s-1 × cm-5, p < 0.001); (4) Conclusions: CO and CI can be measured with whole-body ICG among hospitalized CHF patients with acceptable accuracy. The reliability of measuring TPR and PVR should be further investigated.