Development and validation of a fast LC-MS/MS method for the quantitation of creatine and taurine in sports supplements.

IF 1.5 4区 医学 Q4 CHEMISTRY, MEDICINAL
Pharmazie Pub Date : 2025-03-31 DOI:10.1691/ph.2025.4059
R van der Merwe, W Liebenberg, H J R Lemmer, F van der Kooy
{"title":"Development and validation of a fast LC-MS/MS method for the quantitation of creatine and taurine in sports supplements.","authors":"R van der Merwe, W Liebenberg, H J R Lemmer, F van der Kooy","doi":"10.1691/ph.2025.4059","DOIUrl":null,"url":null,"abstract":"<p><p>Sports supplements containing a combination of creatine and taurine have seen a dramatic rise in popularity. However, adequate analytical techniques for the quantification of these metabolites in tissue samples and supplements are essential. Liquid chromatography mass spectrometry offers a selective and sensitive alternative but to date, no method has been reported for the quantification of both compounds in combination. The main objective was to develop and validate a fast analytical method using LC-MS/MS and to test its suitability on seven commercial sports supplements. An isocratic method with a run time of 2.5 min using a hydrophilic interaction liquid chromatography column and multiple reaction monitoring transitions was developed and validated for linearity, precision, LOD and LOQ, ruggedness and recovery. Spiking experiments on seven commercial samples were conducted to test for possible ion enhancement/suppression. All validation parameters fell well within acceptable limits and the spiking recoveries of the commercial samples all fell between 81-116%. The seven products revealed large discrepancies between the measured values by as much as +99.66% for creatine and as low as -83.81% for taurine as compared to the label claims. These discrepancies highlight the importance of quality control, as inaccurate labelling could lead to unintentional overdosing, which may cause gastric issues and, in severe cases, kidney problems.</p>","PeriodicalId":20145,"journal":{"name":"Pharmazie","volume":"80 1","pages":"2-6"},"PeriodicalIF":1.5000,"publicationDate":"2025-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmazie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1691/ph.2025.4059","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MEDICINAL","Score":null,"Total":0}
引用次数: 0

Abstract

Sports supplements containing a combination of creatine and taurine have seen a dramatic rise in popularity. However, adequate analytical techniques for the quantification of these metabolites in tissue samples and supplements are essential. Liquid chromatography mass spectrometry offers a selective and sensitive alternative but to date, no method has been reported for the quantification of both compounds in combination. The main objective was to develop and validate a fast analytical method using LC-MS/MS and to test its suitability on seven commercial sports supplements. An isocratic method with a run time of 2.5 min using a hydrophilic interaction liquid chromatography column and multiple reaction monitoring transitions was developed and validated for linearity, precision, LOD and LOQ, ruggedness and recovery. Spiking experiments on seven commercial samples were conducted to test for possible ion enhancement/suppression. All validation parameters fell well within acceptable limits and the spiking recoveries of the commercial samples all fell between 81-116%. The seven products revealed large discrepancies between the measured values by as much as +99.66% for creatine and as low as -83.81% for taurine as compared to the label claims. These discrepancies highlight the importance of quality control, as inaccurate labelling could lead to unintentional overdosing, which may cause gastric issues and, in severe cases, kidney problems.

快速LC-MS/MS定量运动补充剂中肌酸和牛磺酸方法的建立和验证。
含有肌酸和牛磺酸的运动补充剂的受欢迎程度急剧上升。然而,充分的分析技术定量这些代谢物在组织样品和补充是必不可少的。液相色谱-质谱法提供了一种选择性和敏感性的替代方法,但迄今为止,还没有报道过同时定量这两种化合物的方法。主要目的是开发和验证一种使用LC-MS/MS的快速分析方法,并测试其在七种商业运动补充剂上的适用性。建立了一种运行时间为2.5 min、采用亲水相互作用液相色谱柱和多个反应监测过渡的等压法,并对线性度、精密度、LOD和LOQ、坚固性和回收率进行了验证。在7个商业样品上进行了脉冲实验,以测试可能的离子增强/抑制。所有验证参数均在可接受范围内,商业样品的加峰回收率均在81 ~ 116%之间。与标签声称相比,这7种产品的肌酸和牛磺酸的测量值之间的差异很大,差异高达+99.66%,牛磺酸的差异低至-83.81%。这些差异突出了质量控制的重要性,因为不准确的标签可能导致无意中过量服用,这可能导致胃问题,在严重的情况下,还可能导致肾脏问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Pharmazie
Pharmazie 医学-化学综合
CiteScore
3.10
自引率
0.00%
发文量
56
审稿时长
1.2 months
期刊介绍: The journal DiePharmazie publishs reviews, experimental studies, letters to the editor, as well as book reviews. The following fields of pharmacy are covered: Pharmaceutical and medicinal chemistry; Pharmaceutical analysis and drug control; Pharmaceutical technolgy; Biopharmacy (biopharmaceutics, pharmacokinetics, biotransformation); Experimental and clinical pharmacology; Pharmaceutical biology (pharmacognosy); Clinical pharmacy; History of pharmacy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信