Case Report: Virtual surgery and 3D printing in a medication-related osteonecrosis of the jaws (MRONJ) pathological mandibular fracture.

IF 3 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Frontiers in oral health Pub Date : 2025-03-28 eCollection Date: 2025-01-01 DOI:10.3389/froh.2025.1520195
Giorgio Lo Giudice, Alessandro Calvo, Emanuele Magaudda, Francesco Saverio De Ponte, Enrico Nastro Siniscalchi
{"title":"Case Report: Virtual surgery and 3D printing in a medication-related osteonecrosis of the jaws (MRONJ) pathological mandibular fracture.","authors":"Giorgio Lo Giudice, Alessandro Calvo, Emanuele Magaudda, Francesco Saverio De Ponte, Enrico Nastro Siniscalchi","doi":"10.3389/froh.2025.1520195","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The use of anatomical models, guides, and surgical templates allows for increased precision of interventions and reduced operative times. Thanks to computer-aided design (CAD) and computer-aided manufacturing (CAM) technologies and rapid prototyping through 3D printing, it is possible to obtain accurate models, which are useful to defining surgical planning in the maxillofacial district.</p><p><strong>Methods: </strong>We present the case of a patient with a pathological fracture of the mandibular body affected by medication-related osteonecrosis of the jaws (MRONJ) in stage III. Through the manipulation of virtual models obtained from thin-layer Computed Tomography (CT), a virtual surgical intervention of sequestrectomy and debridement of necrotic bone tissue, reduction and containment of the fracture was performed. The resulting mandibular model was used as a template for the preoperative modeling of the titanium reconstruction plate used for fracture containment.</p><p><strong>Results: </strong>The intraoperative result and follow-up demonstrated good accuracy of the model with respect to post-operative mandibular dynamics, condylar-fossa position and a reduced surgical time.</p><p><strong>Discussion: </strong>Virtual surgery and 3D-printed prototyping represent a feasible technique in MRONJ patients, allowing increased precision of interventions, reduced risks associated with the operation, and improved operative and recovery times for the patient.</p>","PeriodicalId":94016,"journal":{"name":"Frontiers in oral health","volume":"6 ","pages":"1520195"},"PeriodicalIF":3.0000,"publicationDate":"2025-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11985856/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in oral health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/froh.2025.1520195","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The use of anatomical models, guides, and surgical templates allows for increased precision of interventions and reduced operative times. Thanks to computer-aided design (CAD) and computer-aided manufacturing (CAM) technologies and rapid prototyping through 3D printing, it is possible to obtain accurate models, which are useful to defining surgical planning in the maxillofacial district.

Methods: We present the case of a patient with a pathological fracture of the mandibular body affected by medication-related osteonecrosis of the jaws (MRONJ) in stage III. Through the manipulation of virtual models obtained from thin-layer Computed Tomography (CT), a virtual surgical intervention of sequestrectomy and debridement of necrotic bone tissue, reduction and containment of the fracture was performed. The resulting mandibular model was used as a template for the preoperative modeling of the titanium reconstruction plate used for fracture containment.

Results: The intraoperative result and follow-up demonstrated good accuracy of the model with respect to post-operative mandibular dynamics, condylar-fossa position and a reduced surgical time.

Discussion: Virtual surgery and 3D-printed prototyping represent a feasible technique in MRONJ patients, allowing increased precision of interventions, reduced risks associated with the operation, and improved operative and recovery times for the patient.

病例报告:虚拟手术和3D打印治疗药物相关性颌骨骨坏死(MRONJ)病理性下颌骨骨折。
介绍:使用解剖模型,指南和手术模板可以提高干预的精度,减少手术时间。由于计算机辅助设计(CAD)和计算机辅助制造(CAM)技术以及通过3D打印进行的快速原型制作,可以获得准确的模型,这对于确定颌面区域的手术计划非常有用。方法:我们提出的情况下,病人的下颌骨病理性骨折的影响药物相关性骨坏死(MRONJ)在第三期。通过对薄层计算机断层扫描(CT)获得的虚拟模型的操作,进行了坏死骨组织的隔离切除和清创,复位和遏制骨折的虚拟手术干预。所得到的下颌模型被用作用于骨折遏制的钛重建板的术前建模模板。结果:术中结果和随访表明,该模型在术后下颌动力学、髁窝位置和缩短手术时间方面具有良好的准确性。讨论:虚拟手术和3d打印原型代表了MRONJ患者的一种可行技术,可以提高干预的精度,降低与手术相关的风险,并缩短患者的手术和恢复时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.30
自引率
0.00%
发文量
0
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信