Mustafa Başaran, Fatma Beyazal Çeliker, Metin Çeliker, Kemal Panç, Enes Gürün
{"title":"Diagnostic Value of Dual-Energy CT Iodine Mapping in Differentiating Malignant and Benign Cervical Lymphadenopathies.","authors":"Mustafa Başaran, Fatma Beyazal Çeliker, Metin Çeliker, Kemal Panç, Enes Gürün","doi":"10.1002/jcu.24014","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the diagnostic accuracy of Dual-Energy Computed Tomography (DECT) in distinguishing malignant from benign cervical lymph nodes in neck carcinoma based on iodine concentration and normalized spectral attenuation (Hounsfield Unit, HU) values.</p><p><strong>Methods: </strong>Retrospective DECT scan analysis was performed on 52 neck carcinoma patients, analyzing 52 metastatic and 28 reactive lymph nodes. Iodine concentration (mg/mL) and spectral HU values were measured with circular regions of interest on iodine maps. Metastatic nodes included 27 from squamous cell carcinoma (SCC), 19 from lymphoma, and 6 from papillary thyroid carcinoma (PTC).</p><p><strong>Results: </strong>Metastatic lymph nodes had lower iodine levels than reactive nodes (1.45 vs. 1.85 mg/mL, p = 0.011). No significant difference in spectral HU values was found (117 vs. 111 HU, p = 0.328). An iodine threshold of 1.62 mg/mL demonstrated 71% sensitivity and 77% specificity for detecting malignancy (AUC = 0.673, 95% CI: 0.54-0.80, p = 0.011). SCC metastases had lower iodine levels than reactive nodes (1.33 vs. 1.85 mg/mL, p < 0.001), while PTC metastases had higher levels (2.39 vs. 1.85 mg/mL, p = 0.038).</p><p><strong>Conclusion: </strong>DECT iodine quantification improves the detection of cervical lymph node metastases, particularly in cases with equivocal size criteria. Incorporating iodine measurements with tumor type knowledge improves diagnostic accuracy, aiding in prognosis and treatment planning.</p>","PeriodicalId":15386,"journal":{"name":"Journal of Clinical Ultrasound","volume":" ","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2025-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jcu.24014","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate the diagnostic accuracy of Dual-Energy Computed Tomography (DECT) in distinguishing malignant from benign cervical lymph nodes in neck carcinoma based on iodine concentration and normalized spectral attenuation (Hounsfield Unit, HU) values.
Methods: Retrospective DECT scan analysis was performed on 52 neck carcinoma patients, analyzing 52 metastatic and 28 reactive lymph nodes. Iodine concentration (mg/mL) and spectral HU values were measured with circular regions of interest on iodine maps. Metastatic nodes included 27 from squamous cell carcinoma (SCC), 19 from lymphoma, and 6 from papillary thyroid carcinoma (PTC).
Results: Metastatic lymph nodes had lower iodine levels than reactive nodes (1.45 vs. 1.85 mg/mL, p = 0.011). No significant difference in spectral HU values was found (117 vs. 111 HU, p = 0.328). An iodine threshold of 1.62 mg/mL demonstrated 71% sensitivity and 77% specificity for detecting malignancy (AUC = 0.673, 95% CI: 0.54-0.80, p = 0.011). SCC metastases had lower iodine levels than reactive nodes (1.33 vs. 1.85 mg/mL, p < 0.001), while PTC metastases had higher levels (2.39 vs. 1.85 mg/mL, p = 0.038).
Conclusion: DECT iodine quantification improves the detection of cervical lymph node metastases, particularly in cases with equivocal size criteria. Incorporating iodine measurements with tumor type knowledge improves diagnostic accuracy, aiding in prognosis and treatment planning.
期刊介绍:
The Journal of Clinical Ultrasound (JCU) is an international journal dedicated to the worldwide dissemination of scientific information on diagnostic and therapeutic applications of medical sonography.
The scope of the journal includes--but is not limited to--the following areas: sonography of the gastrointestinal tract, genitourinary tract, vascular system, nervous system, head and neck, chest, breast, musculoskeletal system, and other superficial structures; Doppler applications; obstetric and pediatric applications; and interventional sonography. Studies comparing sonography with other imaging modalities are encouraged, as are studies evaluating the economic impact of sonography. Also within the journal''s scope are innovations and improvements in instrumentation and examination techniques and the use of contrast agents.
JCU publishes original research articles, case reports, pictorial essays, technical notes, and letters to the editor. The journal is also dedicated to being an educational resource for its readers, through the publication of review articles and various scientific contributions from members of the editorial board and other world-renowned experts in sonography.