Investigation of Friction for Nanocoated and Uncoated Ti-6Al-4V Substrates via the Modified Pin-on-Disk Technique for Transfemoral Implants.

Q3 Medicine
Muntadher Saleh Mahdi, Dunya Abdulsahib Hamdi
{"title":"Investigation of Friction for Nanocoated and Uncoated Ti-6Al-4V Substrates via the Modified Pin-on-Disk Technique for Transfemoral Implants.","authors":"Muntadher Saleh Mahdi, Dunya Abdulsahib Hamdi","doi":"10.31661/jbpe.v0i0.2401-1712","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Nanocoating of biomedical materials has emerged as a crucial emerging discipline, to enhance tribological behaviors, durability, and performance of materials.</p><p><strong>Objective: </strong>This study aimed to investigate the tribological characteristics of substrates coated with Hydroxyapatite (HAp) and Silica glass (SiO2).</p><p><strong>Material and methods: </strong>In this experimental study, the substrates were Ti-6Al-4V, a widely used titanium alloy for osseointegration implants. The substrates were coated with 90% HAp and 10% SiO2 via the plasma cold spray technique. The friction examination was analyzed at room temperature and under the Simulated Body Fluid (SBF) condition using the pin-on-disc technique.</p><p><strong>Results: </strong>The microstructural analysis confirmed the coated technique in producing a nano-sized layer. While the pin-on-disc test indicates that nanocoated Ti-6Al-4V specimens have a significantly higher average coefficient of friction than uncoated specimens, surface roughness is the primary contributor.</p><p><strong>Conclusion: </strong>Through microstructure properties and tribological behavior, the coated alloy may provide a benefit in circumstances, in which lubrication availability is restricted or undesirable, such as when the implant comes into contact with the bone interface.</p>","PeriodicalId":38035,"journal":{"name":"Journal of Biomedical Physics and Engineering","volume":"15 2","pages":"115-124"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12009464/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31661/jbpe.v0i0.2401-1712","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Nanocoating of biomedical materials has emerged as a crucial emerging discipline, to enhance tribological behaviors, durability, and performance of materials.

Objective: This study aimed to investigate the tribological characteristics of substrates coated with Hydroxyapatite (HAp) and Silica glass (SiO2).

Material and methods: In this experimental study, the substrates were Ti-6Al-4V, a widely used titanium alloy for osseointegration implants. The substrates were coated with 90% HAp and 10% SiO2 via the plasma cold spray technique. The friction examination was analyzed at room temperature and under the Simulated Body Fluid (SBF) condition using the pin-on-disc technique.

Results: The microstructural analysis confirmed the coated technique in producing a nano-sized layer. While the pin-on-disc test indicates that nanocoated Ti-6Al-4V specimens have a significantly higher average coefficient of friction than uncoated specimens, surface roughness is the primary contributor.

Conclusion: Through microstructure properties and tribological behavior, the coated alloy may provide a benefit in circumstances, in which lubrication availability is restricted or undesirable, such as when the implant comes into contact with the bone interface.

经股骨植入物改良针盘技术对纳米涂层和未涂层Ti-6Al-4V衬底摩擦的研究。
背景:生物医学材料的纳米涂层已经成为一个重要的新兴学科,以提高材料的摩擦学行为,耐久性和性能。目的:研究羟基磷灰石(HAp)和二氧化硅玻璃(SiO2)涂层的摩擦学特性。材料与方法:本实验研究的基质为Ti-6Al-4V,这是一种广泛应用于骨整合种植体的钛合金。采用等离子体冷喷涂技术对基体进行了90% HAp和10% SiO2的涂层处理。在室温和模拟体液(SBF)条件下,采用针盘技术进行了摩擦试验分析。结果:显微组织分析证实了采用包覆技术制备纳米层的可行性。虽然销盘试验表明,纳米涂层Ti-6Al-4V试样的平均摩擦系数明显高于未涂层试样,但表面粗糙度是主要因素。结论:通过微观结构特性和摩擦学行为,涂层合金可以在润滑可用性受限或不需要的情况下提供益处,例如当种植体与骨界面接触时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Biomedical Physics and Engineering
Journal of Biomedical Physics and Engineering Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
2.90
自引率
0.00%
发文量
64
审稿时长
10 weeks
期刊介绍: The Journal of Biomedical Physics and Engineering (JBPE) is a bimonthly peer-reviewed English-language journal that publishes high-quality basic sciences and clinical research (experimental or theoretical) broadly concerned with the relationship of physics to medicine and engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信