Mary M.L. Lee , George B. Schuessler , Kevin Lau , Shu Chien
{"title":"Effects of pressure on vesicle size, density, and distribution in the canine carotid arterial endothelium","authors":"Mary M.L. Lee , George B. Schuessler , Kevin Lau , Shu Chien","doi":"10.1016/0889-1605(88)90014-6","DOIUrl":null,"url":null,"abstract":"<div><p>The purpose of the present experiment was to study the effects of internal hydrostatic pressure on vesicle size, density, and distribution in the canine carotid arterial endothelium by transmission electron microscopy. The pressures applied in this study were 0 (control), 40, 60, 80, 100, and 150 mm Hg. The results of transmission electron microscopy and computer analysis on the plasmalemmal vesicles of aortic endothelium showed that luminal, abluminal, and junctional vesicles all increased their diameter as the pressure was raised from 0 mm Hg, reaching a maximum at 80 mm Hg, and then decreased in size with further increases in pressure to 150 mm Hg. There was a significant difference in diameter among vesicles in different regions of the endothelium, with the diameter of luminal vesicles larger than those of abluminal and junctional vesicles. The densities of vesicles showed very little change from 0 to 80 mm Hg; but they increased markedly as the pressure was further raised from 80 to 150 mm Hg. These results indicate that pressure is an important mechanical factor governing the size and density of plasmalemmal vesicles in aortic endothelium.</p></div>","PeriodicalId":77743,"journal":{"name":"Journal of ultrastructure and molecular structure research","volume":"101 2","pages":"Pages 236-242"},"PeriodicalIF":0.0000,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0889-1605(88)90014-6","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of ultrastructure and molecular structure research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0889160588900146","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
The purpose of the present experiment was to study the effects of internal hydrostatic pressure on vesicle size, density, and distribution in the canine carotid arterial endothelium by transmission electron microscopy. The pressures applied in this study were 0 (control), 40, 60, 80, 100, and 150 mm Hg. The results of transmission electron microscopy and computer analysis on the plasmalemmal vesicles of aortic endothelium showed that luminal, abluminal, and junctional vesicles all increased their diameter as the pressure was raised from 0 mm Hg, reaching a maximum at 80 mm Hg, and then decreased in size with further increases in pressure to 150 mm Hg. There was a significant difference in diameter among vesicles in different regions of the endothelium, with the diameter of luminal vesicles larger than those of abluminal and junctional vesicles. The densities of vesicles showed very little change from 0 to 80 mm Hg; but they increased markedly as the pressure was further raised from 80 to 150 mm Hg. These results indicate that pressure is an important mechanical factor governing the size and density of plasmalemmal vesicles in aortic endothelium.
通过透射电镜观察静水压力对犬颈动脉内皮小泡大小、密度和分布的影响。本研究施加的压力分别为0(对照)、40、60、80、100和150 mm Hg。通过对主动脉内皮质浆小泡的透射电镜和计算机分析发现,随着压力的增加,管腔、管腔和连接小泡的直径都在增加,在80 mm Hg时达到最大值。内皮不同区域的囊泡直径差异显著,管腔囊泡直径大于管腔囊泡和交界囊泡直径。在0 ~ 80 mm Hg范围内,囊泡密度变化不大;当压力从80 mm Hg升高到150 mm Hg时,内皮小泡的大小和密度随压力的增加而明显增加。