{"title":"[Three-dimensional finite element analysis of digital wire loop space maintainers for missing deciduous teeth].","authors":"Lijuan Ma, Yonghui Teng, Yong Wang, Yijiao Zhao, Xinyue Zhang, Qingzhao Qin, Dong Yin","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To establish a three-dimensional finite element model of a digital wire loop space maintainer for the mandible and primary tooth loss, in order to investigate the stress, deformation, and shear force experienced by patients with the loss of the second primary molar when wearing the wire loop space maintainer.</p><p><strong>Methods: </strong>Cone beam computed tomography (CBCT) scans were performed on the patients to create a digital model of the mandible with the absence of the second primary molar using Mimics 21.0 software. A digital model integrating the crown's retention and the wire loop structure of the full crown and ring wire loop space maintainer was constructed using pediatric space maintainer design software, utilizing three different materials: cobalt-chromium alloy, polyether ether ketone (PEEK), and titanium alloy. In ANSYS Work Beach 2023 R2 software, vertical loads of 70 N, tilted 45° along the long axis of the tooth loads of 70 N, and a 10 N load on the surface of the wire loop were applied to the occlusal surfaces of models 46 and 84, simulating centric and lateral occlusions during chewing with the wire loop space maintainer in place. The stress states of the wire loop space maintainer and supporting teeth were analyzed.</p><p><strong>Results: </strong>Under various loading conditions, the maximum principal stress of the ring wire loop space maintainer was significantly lower than that of the full crown. Stress contour maps indicated that the peak of the maximum principal stress occurred at the junction of the wire loop and crown structure, indicating that this area was more susceptible to fracture. The ring wire loop space maintainer made from PEEK material exhibited the lowest maximum shear stress on the internal organizational surfaces, with equivalent stresses of 23.18 MPa and 36.35 MPa for models 46 and 84, respectively. Stress contour maps demonstrated that the maximum stress on tooth 46 was located at its mesial, while the maximum stress on tooth 84 was situated near the root area on its distal, in contact with the wire loop space maintainer.</p><p><strong>Conclusion: </strong>In cases of second primary molar loss, wearing the digital ring wire loop space maintainer can effectively distribute stress, and the ring wire loop space maintainer made from PEEK material reduces the stress experienced by supporting teeth to some extent, demonstrating its superiority in clinical application.</p>","PeriodicalId":8790,"journal":{"name":"北京大学学报(医学版)","volume":"57 2","pages":"376-383"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11992462/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"北京大学学报(医学版)","FirstCategoryId":"3","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To establish a three-dimensional finite element model of a digital wire loop space maintainer for the mandible and primary tooth loss, in order to investigate the stress, deformation, and shear force experienced by patients with the loss of the second primary molar when wearing the wire loop space maintainer.
Methods: Cone beam computed tomography (CBCT) scans were performed on the patients to create a digital model of the mandible with the absence of the second primary molar using Mimics 21.0 software. A digital model integrating the crown's retention and the wire loop structure of the full crown and ring wire loop space maintainer was constructed using pediatric space maintainer design software, utilizing three different materials: cobalt-chromium alloy, polyether ether ketone (PEEK), and titanium alloy. In ANSYS Work Beach 2023 R2 software, vertical loads of 70 N, tilted 45° along the long axis of the tooth loads of 70 N, and a 10 N load on the surface of the wire loop were applied to the occlusal surfaces of models 46 and 84, simulating centric and lateral occlusions during chewing with the wire loop space maintainer in place. The stress states of the wire loop space maintainer and supporting teeth were analyzed.
Results: Under various loading conditions, the maximum principal stress of the ring wire loop space maintainer was significantly lower than that of the full crown. Stress contour maps indicated that the peak of the maximum principal stress occurred at the junction of the wire loop and crown structure, indicating that this area was more susceptible to fracture. The ring wire loop space maintainer made from PEEK material exhibited the lowest maximum shear stress on the internal organizational surfaces, with equivalent stresses of 23.18 MPa and 36.35 MPa for models 46 and 84, respectively. Stress contour maps demonstrated that the maximum stress on tooth 46 was located at its mesial, while the maximum stress on tooth 84 was situated near the root area on its distal, in contact with the wire loop space maintainer.
Conclusion: In cases of second primary molar loss, wearing the digital ring wire loop space maintainer can effectively distribute stress, and the ring wire loop space maintainer made from PEEK material reduces the stress experienced by supporting teeth to some extent, demonstrating its superiority in clinical application.
期刊介绍:
Beijing Da Xue Xue Bao Yi Xue Ban / Journal of Peking University (Health Sciences), established in 1959, is a national academic journal sponsored by Peking University, and its former name is Journal of Beijing Medical University. The coverage of the Journal includes basic medical sciences, clinical medicine, oral medicine, surgery, public health and epidemiology, pharmacology and pharmacy. Over the last few years, the Journal has published articles and reports covering major topics in the different special issues (e.g. research on disease genome, theory of drug withdrawal, mechanism and prevention of cardiovascular and cerebrovascular diseases, stomatology, orthopaedic, public health, urology and reproductive medicine). All the topics involve latest advances in medical sciences, hot topics in specific specialties, and prevention and treatment of major diseases.
The Journal has been indexed and abstracted by PubMed Central (PMC), MEDLINE/PubMed, EBSCO, Embase, Scopus, Chemical Abstracts (CA), Western Pacific Region Index Medicus (WPR), JSTChina, and almost all the Chinese sciences and technical index systems, including Chinese Science and Technology Paper Citation Database (CSTPCD), Chinese Science Citation Database (CSCD), China BioMedical Bibliographic Database (CBM), CMCI, Chinese Biological Abstracts, China National Academic Magazine Data-Base (CNKI), Wanfang Data (ChinaInfo), etc.