The effect of storage conditions and duration on dimensional stability of 3D-printed endoguides.

IF 2.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Yunus Emre Ozden, Idil Ozden, Zeynep Ozkurt Kayahan, Ender Kazazoglu
{"title":"The effect of storage conditions and duration on dimensional stability of 3D-printed endoguides.","authors":"Yunus Emre Ozden, Idil Ozden, Zeynep Ozkurt Kayahan, Ender Kazazoglu","doi":"10.1186/s12903-025-06008-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study evaluated the dimensional stability and angular deviations of 3D-printed endodontic guides under varying storage conditions (wet vs. dry, dark vs. daylight) and durations (7 vs. 14 days).</p><p><strong>Methods: </strong>Endodontic guides for the localization of obliterated canals were designed using BlueSkyPlan software (BlueSky Bio, IL, USA) and printed with Biomed Clear Resin V2 (Formlabs Inc., Somerville, USA) via SLA technology. A total of 40 endodontic guides were fabricated and divided into four groups (n = 10), each subjected to either light or dark storage conditions for durations of 7 or 14 days. Dimensional stability was assessed using root mean square (RMS) and angular deviations in Geomagic Design X (Oqton, USA). Statistical analyses were performed using IBM SPSS v29 with independent samples and paired t-tests (p = 0.05).</p><p><strong>Results: </strong>Guides stored in dry conditions had lower RMS (0.052 ± 0.013) and angular deviations (0.29 ± 0.11) than wet conditions (RMS: 0.069 ± 0.028, p = 0.001; angle: 0.36 ± 0.11, p = 0.008). Angular deviations increased at 14 days (p = 0.003). Daylight exposure increased RMS deviations at 14 days in dry conditions (p = 0.001). Wet storage in dark conditions led to greater deviations at both time intervals(p < 0.05).</p><p><strong>Conclusions: </strong>Storage conditions and duration significantly affect the dimensional stability of 3D-printed endodontic guides. Wet storage and prolonged duration reduce accuracy. To maintain precision, guides should be used within 7 days and stored in dry, dark environments.</p><p><strong>Clinical trial number: </strong>Not applicable.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"641"},"PeriodicalIF":2.6000,"publicationDate":"2025-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12032804/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-025-06008-z","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: This study evaluated the dimensional stability and angular deviations of 3D-printed endodontic guides under varying storage conditions (wet vs. dry, dark vs. daylight) and durations (7 vs. 14 days).

Methods: Endodontic guides for the localization of obliterated canals were designed using BlueSkyPlan software (BlueSky Bio, IL, USA) and printed with Biomed Clear Resin V2 (Formlabs Inc., Somerville, USA) via SLA technology. A total of 40 endodontic guides were fabricated and divided into four groups (n = 10), each subjected to either light or dark storage conditions for durations of 7 or 14 days. Dimensional stability was assessed using root mean square (RMS) and angular deviations in Geomagic Design X (Oqton, USA). Statistical analyses were performed using IBM SPSS v29 with independent samples and paired t-tests (p = 0.05).

Results: Guides stored in dry conditions had lower RMS (0.052 ± 0.013) and angular deviations (0.29 ± 0.11) than wet conditions (RMS: 0.069 ± 0.028, p = 0.001; angle: 0.36 ± 0.11, p = 0.008). Angular deviations increased at 14 days (p = 0.003). Daylight exposure increased RMS deviations at 14 days in dry conditions (p = 0.001). Wet storage in dark conditions led to greater deviations at both time intervals(p < 0.05).

Conclusions: Storage conditions and duration significantly affect the dimensional stability of 3D-printed endodontic guides. Wet storage and prolonged duration reduce accuracy. To maintain precision, guides should be used within 7 days and stored in dry, dark environments.

Clinical trial number: Not applicable.

存放条件和存放时间对3d打印内导管尺寸稳定性的影响。
背景:本研究评估了3d打印根管导板在不同储存条件(潮湿与干燥、黑暗与日光)和持续时间(7天与14天)下的尺寸稳定性和角度偏差。方法:采用BlueSkyPlan软件(BlueSky Bio, IL, USA)设计根管闭塞定位指南,采用Biomed Clear Resin V2 (Formlabs Inc., Somerville, USA)通过SLA技术进行打印。共制作40根根管引导棒,分为4组(n = 10),每组分别在光照或黑暗条件下保存7天或14天。尺寸稳定性评估采用均方根(RMS)和角度偏差在Geomagic Design X (Oqton, USA)。采用IBM SPSS v29进行统计学分析,采用独立样本和配对t检验(p = 0.05)。结果:干燥条件下导管的RMS(0.052±0.013)和角度偏差(0.29±0.11)低于湿润条件下(RMS: 0.069±0.028,p = 0.001);角度:0.36±0.11,p = 0.008)。角度偏差在第14天增加(p = 0.003)。在干燥条件下,日光暴露增加了14天的RMS偏差(p = 0.001)。结论:存放条件和存放时间对3d打印根管导具的尺寸稳定性有显著影响。潮湿的储存和长时间的持续时间降低准确性。为保持精度,导轨应在7天内使用,并存放在干燥、黑暗的环境中。临床试验号:不适用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信