Alterations in tidal volume over recording time during pulmonary function testing by barometric whole-body plethysmography in client-owned cats: a multicenter retrospective investigation.

IF 2.3 2区 农林科学 Q1 VETERINARY SCIENCES
Wei-Tao Chang, Laín García-Guasch, Hannah Gareis, Bianka Schulz, Yoshiki Yamaya, Pei-Ying Lo, Chin-Hao Chang, Hui-Wen Chen, Chung-Hui Lin
{"title":"Alterations in tidal volume over recording time during pulmonary function testing by barometric whole-body plethysmography in client-owned cats: a multicenter retrospective investigation.","authors":"Wei-Tao Chang, Laín García-Guasch, Hannah Gareis, Bianka Schulz, Yoshiki Yamaya, Pei-Ying Lo, Chin-Hao Chang, Hui-Wen Chen, Chung-Hui Lin","doi":"10.1186/s12917-025-04774-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pulmonary function assessment in small animal clinical patients typically relies on tidal breathing analysis, such as placing cats in a barometric whole-body plethysmography (BWBP) chamber. Despite its wide application in various clinical scenarios, the recording time for BWBP has not been standardized. Variability in resting tidal volume (TV) during natural breathing is significant, impacting the detection of airflow limitation in obstructive airway disease. This multicenter investigation aimed to examine the consistency of TV alterations over the BWBP recording period across different regions, identify influential factors associated with signalment or emotion of the cat, and determine whether the recording time for BWBP in clinical cats could be shorter than in previous studies.</p><p><strong>Results: </strong>This is a multicenter retrospective study. A total of 131 BWBP recordings from clinical cats across four sites in different countries were enrolled. Ventilatory parameters calculated from short sections using 5 and 20 breaths at the first site showed no significant difference (P > 0.05). Among all sites, TV of the initial period (TV-initial, median 32.5 mL, range 4.9-162.9) was significantly greater than TV of the middle (TV-mid, 29.9 mL, range 6.7-144.6) (P < 0.001) and the late (TV-late, 27.5 mL, range 5.1-144.8) (P < 0.001) period of the recording, while TV-mid and TV-late were not significantly different (P = 0.19). The trend of alterations in TV was not affected by site, emotional status, health status, age, or gender. Forest plots with 95% confidence intervals of TV generated from short sections, alongside conventional data averaging breaths over a 5-minute period (TV-All), showed acceptable margins of error at all sites. TV-mid and TV-late were closest to TV-All, whereas TV-initial was larger than TV-mid, TV-late, and TV-All.</p><p><strong>Conclusions: </strong>TV in clinical cats within the BWBP chamber tends to decrease with recording time. When a shorter section of breaths is desired for clinical evaluation, selecting 5 or 20 breaths from the beginning period of recording would have a higher TV, which might be advantageous for investigating obstructive airway problems. Alternatively, breaths selected from the middle or later stages of recording would be more representative of relaxed breathing over a longer period of time.</p>","PeriodicalId":9041,"journal":{"name":"BMC Veterinary Research","volume":"21 1","pages":"304"},"PeriodicalIF":2.3000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12044765/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Veterinary Research","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1186/s12917-025-04774-0","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Pulmonary function assessment in small animal clinical patients typically relies on tidal breathing analysis, such as placing cats in a barometric whole-body plethysmography (BWBP) chamber. Despite its wide application in various clinical scenarios, the recording time for BWBP has not been standardized. Variability in resting tidal volume (TV) during natural breathing is significant, impacting the detection of airflow limitation in obstructive airway disease. This multicenter investigation aimed to examine the consistency of TV alterations over the BWBP recording period across different regions, identify influential factors associated with signalment or emotion of the cat, and determine whether the recording time for BWBP in clinical cats could be shorter than in previous studies.

Results: This is a multicenter retrospective study. A total of 131 BWBP recordings from clinical cats across four sites in different countries were enrolled. Ventilatory parameters calculated from short sections using 5 and 20 breaths at the first site showed no significant difference (P > 0.05). Among all sites, TV of the initial period (TV-initial, median 32.5 mL, range 4.9-162.9) was significantly greater than TV of the middle (TV-mid, 29.9 mL, range 6.7-144.6) (P < 0.001) and the late (TV-late, 27.5 mL, range 5.1-144.8) (P < 0.001) period of the recording, while TV-mid and TV-late were not significantly different (P = 0.19). The trend of alterations in TV was not affected by site, emotional status, health status, age, or gender. Forest plots with 95% confidence intervals of TV generated from short sections, alongside conventional data averaging breaths over a 5-minute period (TV-All), showed acceptable margins of error at all sites. TV-mid and TV-late were closest to TV-All, whereas TV-initial was larger than TV-mid, TV-late, and TV-All.

Conclusions: TV in clinical cats within the BWBP chamber tends to decrease with recording time. When a shorter section of breaths is desired for clinical evaluation, selecting 5 or 20 breaths from the beginning period of recording would have a higher TV, which might be advantageous for investigating obstructive airway problems. Alternatively, breaths selected from the middle or later stages of recording would be more representative of relaxed breathing over a longer period of time.

在客户养猫的气压式全身容积描记术检测肺功能期间,记录时间内潮气量的变化:一项多中心回顾性调查。
背景:小动物临床患者的肺功能评估通常依赖于潮汐呼吸分析,例如将猫置于气压全身体积脉搏描记(BWBP)室中。尽管BWBP在各种临床场景中得到了广泛的应用,但其记录时间尚未标准化。自然呼吸时静息潮气量(TV)的变化显著,影响阻塞性气道疾病中气流受限的检测。这项多中心研究旨在检验不同地区记录猫腰痛bp期间电视变化的一致性,确定与猫的信号或情绪相关的影响因素,并确定临床猫腰痛bp的记录时间是否可以比以前的研究更短。结果:这是一项多中心回顾性研究。来自不同国家四个地点的临床猫的131次BWBP记录被纳入研究。在第一个部位进行5次和20次呼吸的短切片计算的通气参数差异无统计学意义(P < 0.05)。在所有部位中,初期TV (TV-initial,中位数32.5 mL,范围4.9 ~ 162.9)显著大于中期TV (TV-mid, 29.9 mL,范围6.7 ~ 144.6)(P结论:临床猫在BWBP腔内的TV随记录时间的延长呈下降趋势。当临床评估需要较短的呼吸时段时,从记录的开始阶段选择5或20次呼吸将具有较高的TV,这可能有利于调查阻塞性气道问题。或者,从记录的中间或后期阶段选择的呼吸将更能代表较长时间内的放松呼吸。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Veterinary Research
BMC Veterinary Research VETERINARY SCIENCES-
CiteScore
4.80
自引率
3.80%
发文量
420
审稿时长
3-6 weeks
期刊介绍: BMC Veterinary Research is an open access, peer-reviewed journal that considers articles on all aspects of veterinary science and medicine, including the epidemiology, diagnosis, prevention and treatment of medical conditions of domestic, companion, farm and wild animals, as well as the biomedical processes that underlie their health.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信