{"title":"Simultaneous Ex Situ Normothermic Perfusion of Paired Kidneys in Pigs.","authors":"Margaux Navez, Nicholas Gilbo, Morgan Vandermeulen, Tiago Pinto Coelho, Pauline Erpicum, Marc Gilbert Lagny, Clarisse Malisoux, Claire Guarin, Gabriel Thierry, Pierre Delanaye, Etienne Cavalier, François Jouret, Olivier Detry","doi":"10.1111/aor.15016","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Normothermic Machine Perfusion (NMP) is essential in renal transplantation to improve organ viability before transplantation. This study presents a proof of concept for simultaneous ex situ perfusion of paired porcine kidneys using exogenous creatinine and iohexol clearances to assess renal function, with the primary objective of examining intra-individual differences.</p><p><strong>Methods: </strong>Five kidney pairs (n = 10) were harvested from pigs, preserved at 4°C for 3 h, and subjected to 6-h NMP. Each pair was perfused with a solution containing red blood cells, and perfusion parameters were monitored continuously. Biochemical parameters were assessed using hourly perfusate and urine samples. Kidney function was evaluated using creatinine, which was introduced during the priming procedure.</p><p><strong>Results: </strong>No significant differences were observed between paired kidneys in terms of perfusion and biochemical parameters. Both kidneys maintained stable mean arterial pressures (67.40 ± 12.08 mmHg for right vs. 71.50 ± 4.36 mmHg for left) and flows (68.90 ± 38.61 mL/min vs. 54.00 ± 26.08 mL/min), with consistent electrolyte balance and pH levels. The high inter-individual variability in perfusion and biochemical parameters underscores the importance of paired comparisons.</p><p><strong>Conclusions: </strong>This pig model of simultaneous NMP of paired kidneys demonstrates that the intra-individual variance is low, which makes it possible to test treatments prior to kidney transplantation using one kidney as a valid comparator of the other.</p>","PeriodicalId":8450,"journal":{"name":"Artificial organs","volume":" ","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Artificial organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/aor.15016","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Normothermic Machine Perfusion (NMP) is essential in renal transplantation to improve organ viability before transplantation. This study presents a proof of concept for simultaneous ex situ perfusion of paired porcine kidneys using exogenous creatinine and iohexol clearances to assess renal function, with the primary objective of examining intra-individual differences.
Methods: Five kidney pairs (n = 10) were harvested from pigs, preserved at 4°C for 3 h, and subjected to 6-h NMP. Each pair was perfused with a solution containing red blood cells, and perfusion parameters were monitored continuously. Biochemical parameters were assessed using hourly perfusate and urine samples. Kidney function was evaluated using creatinine, which was introduced during the priming procedure.
Results: No significant differences were observed between paired kidneys in terms of perfusion and biochemical parameters. Both kidneys maintained stable mean arterial pressures (67.40 ± 12.08 mmHg for right vs. 71.50 ± 4.36 mmHg for left) and flows (68.90 ± 38.61 mL/min vs. 54.00 ± 26.08 mL/min), with consistent electrolyte balance and pH levels. The high inter-individual variability in perfusion and biochemical parameters underscores the importance of paired comparisons.
Conclusions: This pig model of simultaneous NMP of paired kidneys demonstrates that the intra-individual variance is low, which makes it possible to test treatments prior to kidney transplantation using one kidney as a valid comparator of the other.
期刊介绍:
Artificial Organs is the official peer reviewed journal of The International Federation for Artificial Organs (Members of the Federation are: The American Society for Artificial Internal Organs, The European Society for Artificial Organs, and The Japanese Society for Artificial Organs), The International Faculty for Artificial Organs, the International Society for Rotary Blood Pumps, The International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation. Artificial Organs publishes original research articles dealing with developments in artificial organs applications and treatment modalities and their clinical applications worldwide. Membership in the Societies listed above is not a prerequisite for publication. Articles are published without charge to the author except for color figures and excess page charges as noted.