Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System

Charlotte L.C. Smith, Gerben J. C. Zwezerijnen, Marijke E. den Hollander, Josée M. Zijlstra, C. Willemien Menke-van der Houven van Oordt, Idris Bahce, Maqsood Yaqub, Ronald Boellaard
{"title":"Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System","authors":"Charlotte L.C. Smith, Gerben J. C. Zwezerijnen, Marijke E. den Hollander, Josée M. Zijlstra, C. Willemien Menke-van der Houven van Oordt, Idris Bahce, Maqsood Yaqub, Ronald Boellaard","doi":"10.2967/jnumed.124.269272","DOIUrl":null,"url":null,"abstract":"<p><sup>18</sup>F-FDG PET/CT imaging is widely used in oncology. Long–axial-field-of-view (LAFOV) PET/CT systems exhibit ultrahigh sensitivity and signal-to-noise ratios, enabling significant reductions in tracer activity and shorter acquisition times. This study aimed to evaluate the feasibility of using ultralow activities for semiquantitative measurements in <sup>18</sup>F-FDG PET/CT imaging performed on an LAFOV PET/CT system through a high–low activity test–retest study. <strong>Methods:</strong> Eleven oncology patients underwent 2 <sup>18</sup>F-FDG PET/CT scans, the first with standard activity (3.0 MBq/kg) and, within 7 d, 1 with ultralow activity (0.3 MBq/kg). List-mode data of both scans were resampled to simulate activities of 0.3 and 0.03 MBq/kg. Semiquantitative measurements (SUV<sub>mean</sub>, SUV<sub>peak</sub>, and SUV<sub>max</sub>) and their repeatability in healthy organs and lesions were compared across different activities and reconstruction protocols. <strong>Results:</strong> SUV<sub>mean</sub> remained stable across activity reductions and reconstruction protocols, whereas SUV<sub>peak</sub> showed stability except when simulating 1% of the standard <sup>18</sup>F-FDG activity. SUV<sub>max</sub> significantly increased at lower <sup>18</sup>F-FDG activities, particularly with clinically preferred scans. Repeatability analysis showed that SUV<sub>mean</sub> and SUV<sub>peak</sub> maintained variability within acceptable limits (&lt;15%) even at 0.03 MBq/kg, whereas SUV<sub>max</sub> variability often exceeded these limits. Lesion detection was reliable at 0.3 MBq/kg, but several lesions could not be delineated at 0.03 MBq/kg, indicating compromised image quality. <strong>Conclusion:</strong> The use of ultralow <sup>18</sup>F-FDG activity (0.3 MBq/kg) is feasible for PET/CT imaging on an LAFOV PET/CT system, as shown by semiquantitative measurements, repeatability analyses, lesion detectability, and semiautomated delineation methods. These findings support imaging protocols that keep radiation exposure levels as low as reasonably or practically achievable, which are particularly relevant for radiation-sensitive patients (e.g., children, pregnant women).</p>","PeriodicalId":22820,"journal":{"name":"The Journal of Nuclear Medicine","volume":"17 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2967/jnumed.124.269272","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

18F-FDG PET/CT imaging is widely used in oncology. Long–axial-field-of-view (LAFOV) PET/CT systems exhibit ultrahigh sensitivity and signal-to-noise ratios, enabling significant reductions in tracer activity and shorter acquisition times. This study aimed to evaluate the feasibility of using ultralow activities for semiquantitative measurements in 18F-FDG PET/CT imaging performed on an LAFOV PET/CT system through a high–low activity test–retest study. Methods: Eleven oncology patients underwent 2 18F-FDG PET/CT scans, the first with standard activity (3.0 MBq/kg) and, within 7 d, 1 with ultralow activity (0.3 MBq/kg). List-mode data of both scans were resampled to simulate activities of 0.3 and 0.03 MBq/kg. Semiquantitative measurements (SUVmean, SUVpeak, and SUVmax) and their repeatability in healthy organs and lesions were compared across different activities and reconstruction protocols. Results: SUVmean remained stable across activity reductions and reconstruction protocols, whereas SUVpeak showed stability except when simulating 1% of the standard 18F-FDG activity. SUVmax significantly increased at lower 18F-FDG activities, particularly with clinically preferred scans. Repeatability analysis showed that SUVmean and SUVpeak maintained variability within acceptable limits (<15%) even at 0.03 MBq/kg, whereas SUVmax variability often exceeded these limits. Lesion detection was reliable at 0.3 MBq/kg, but several lesions could not be delineated at 0.03 MBq/kg, indicating compromised image quality. Conclusion: The use of ultralow 18F-FDG activity (0.3 MBq/kg) is feasible for PET/CT imaging on an LAFOV PET/CT system, as shown by semiquantitative measurements, repeatability analyses, lesion detectability, and semiautomated delineation methods. These findings support imaging protocols that keep radiation exposure levels as low as reasonably or practically achievable, which are particularly relevant for radiation-sensitive patients (e.g., children, pregnant women).

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信