Investigations Into the Urinary Metabolite Elimination Profile of the Selective Androgen Receptor Modulator S-23 in Studies Mimicking Contaminated Product Ingestion for Doping Control Purposes

IF 1.8 4区 医学 Q4 BIOCHEMICAL RESEARCH METHODS
Hana Alhalabi, Linus Korsmeier, Andreas Thomas, Mario Thevis
{"title":"Investigations Into the Urinary Metabolite Elimination Profile of the Selective Androgen Receptor Modulator S-23 in Studies Mimicking Contaminated Product Ingestion for Doping Control Purposes","authors":"Hana Alhalabi,&nbsp;Linus Korsmeier,&nbsp;Andreas Thomas,&nbsp;Mario Thevis","doi":"10.1002/bmc.70090","DOIUrl":null,"url":null,"abstract":"<p>Selective androgen receptor modulators (SARMs) have repeatedly been reason of adverse analytical findings (AAFs) in routine doping controls. Among these, S-23 has been identified in five AAFs reported in 2022. In addition to intentional doping, inadvertent exposure through contaminated dietary supplements has emerged as a significant concern, purportedly as well as evidently contributing to AAFs involving SARMs. Thus, the differentiation of inadvertent intake and intentional abuse of S-23 is of growing relevance. This study aimed at investigating the urinary concentration profile of microdosed S-23 and to characterize the elimination pattern. Single and multidose administration studies with 1, 10, and 50 μg of S-23 were conducted, and collected urine samples were analyzed by LC–MS/MS following enzymatic hydrolysis and solid-phase extraction. The analytical method was validated for a semiquantitative detection of S-23 and characterized by a limit of detection of 1 pg/mL. A total of 18 metabolites was detected in human in vivo samples following oral administration of microdosed S-23. Moreover, the study demonstrated that a single dose of 1 μg can be detected for an average of up to 253 h, while a single dose of 50 μg can be detected up to 544 h on average.</p>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"39 6","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/bmc.70090","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bmc.70090","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Selective androgen receptor modulators (SARMs) have repeatedly been reason of adverse analytical findings (AAFs) in routine doping controls. Among these, S-23 has been identified in five AAFs reported in 2022. In addition to intentional doping, inadvertent exposure through contaminated dietary supplements has emerged as a significant concern, purportedly as well as evidently contributing to AAFs involving SARMs. Thus, the differentiation of inadvertent intake and intentional abuse of S-23 is of growing relevance. This study aimed at investigating the urinary concentration profile of microdosed S-23 and to characterize the elimination pattern. Single and multidose administration studies with 1, 10, and 50 μg of S-23 were conducted, and collected urine samples were analyzed by LC–MS/MS following enzymatic hydrolysis and solid-phase extraction. The analytical method was validated for a semiquantitative detection of S-23 and characterized by a limit of detection of 1 pg/mL. A total of 18 metabolites was detected in human in vivo samples following oral administration of microdosed S-23. Moreover, the study demonstrated that a single dose of 1 μg can be detected for an average of up to 253 h, while a single dose of 50 μg can be detected up to 544 h on average.

Abstract Image

选择性雄激素受体调节剂S-23在模拟兴奋剂控制污染产品摄入研究中的尿代谢物消除谱研究
选择性雄激素受体调节剂(SARMs)已多次成为常规兴奋剂检查中不良分析结果(AAFs)的原因。其中,S-23已在2022年报告的5个aaf中被确定。除了故意使用兴奋剂外,无意中通过受污染的膳食补充剂接触兴奋剂也成为一个重大问题,据称也明显导致了涉及SARMs的aaf。因此,区分无意摄入和故意滥用S-23是越来越重要的。本研究旨在探讨微剂量S-23的尿浓度分布,并表征其消除模式。分别以1、10、50 μg S-23进行单剂量和多剂量给药研究,经酶解和固相萃取后,采用LC-MS /MS对尿液进行分析。该方法可半定量检测S-23,检出限为1 pg/mL。口服微剂量S-23后,在人体内样品中检测到18种代谢物。此外,该研究表明,单次1 μg的检测平均可达253 h,而单次50 μg的检测平均可达544 h。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical Chromatography
Biomedical Chromatography 生物-分析化学
CiteScore
3.60
自引率
5.60%
发文量
268
审稿时长
2.3 months
期刊介绍: Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信