A comparative study on the detection and localization of interictal epileptiform discharges in magnetoencephalography using optically pumped magnetometers versus superconducting quantum interference devices

IF 4.7 2区 医学 Q1 NEUROIMAGING
Jiechuan Ren , Ming Ding , Yuming Peng , Chang Sun , Chunqing Yang , Shuxian Zhou , Jiayin Tian , Qun Wang , Zhimei Li
{"title":"A comparative study on the detection and localization of interictal epileptiform discharges in magnetoencephalography using optically pumped magnetometers versus superconducting quantum interference devices","authors":"Jiechuan Ren ,&nbsp;Ming Ding ,&nbsp;Yuming Peng ,&nbsp;Chang Sun ,&nbsp;Chunqing Yang ,&nbsp;Shuxian Zhou ,&nbsp;Jiayin Tian ,&nbsp;Qun Wang ,&nbsp;Zhimei Li","doi":"10.1016/j.neuroimage.2025.121232","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Superconducting quantum interference device (SQUID)-based magnetoencephalography (MEG) holds substantial clinical value in epilepsy examination but is limited by the high costs. The optically pumped magnetometer (OPM)-based MEG appears promising in overcoming these limitations. This study aims to explore the consistency of interictal epileptiform discharge (IED) detection and source localization between OPM-MEG and SQUID-MEG in a large cohort of patients with epilepsy.</div></div><div><h3>Methods</h3><div>Patients with epilepsy underwent SQUID-MEG and 128-channel whole-scalp OPM-MEG examinations. IED detection, amplitude, signal-to-noise ratio (SNR), sensor-scalp distance, and source localization results were compared between OPM-MEG and SQUID-MEG through statistical analysis.</div></div><div><h3>Results</h3><div>The cohort comprised 46 patients with epilepsy (mean age, 23.7 ± 8.7 [SD] years; 29 male). McNemar <em>χ</em><sup>2</sup> test indicated no significant difference for IED detection between two systems. OPM-MEG achieved a detection accuracy of 91.3 % compared with SQUID-MEG; a Gwet's first-order agreement coefficient (AC<sub>1</sub>) of 0.892 suggested good consistency. Among 39 patients with IEDs detected by both systems, OPM-MEG demonstrated closer sensor-scalp distance (<em>p</em> &lt; 0.001), higher IED amplitude (<em>p</em> &lt; 0.001) and SNR (<em>p</em> = 0.003) compared with SQUID-MEG. At the sublobar level, OPM-MEG and SQUID-MEG exhibited nearly consistent source localization results. Among 24 patients with single dipole clusters, the average centroid distance between dipole clusters of OPM-MEG and SQUID-MEG was 12.16 ± 5.90 mm.</div></div><div><h3>Conclusion</h3><div>This real-world study demonstrated that OPM-MEG had comparable applicability in IED detection and source localization, compared with SQUID-MEG. Additionally, OPM-MEG performed better in terms of IED amplitude and SNR. Lower costs and user-friendly features highlight the clinical potential of OPM-MEG in epilepsy assessments.</div></div>","PeriodicalId":19299,"journal":{"name":"NeuroImage","volume":"312 ","pages":"Article 121232"},"PeriodicalIF":4.7000,"publicationDate":"2025-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NeuroImage","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1053811925002356","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Superconducting quantum interference device (SQUID)-based magnetoencephalography (MEG) holds substantial clinical value in epilepsy examination but is limited by the high costs. The optically pumped magnetometer (OPM)-based MEG appears promising in overcoming these limitations. This study aims to explore the consistency of interictal epileptiform discharge (IED) detection and source localization between OPM-MEG and SQUID-MEG in a large cohort of patients with epilepsy.

Methods

Patients with epilepsy underwent SQUID-MEG and 128-channel whole-scalp OPM-MEG examinations. IED detection, amplitude, signal-to-noise ratio (SNR), sensor-scalp distance, and source localization results were compared between OPM-MEG and SQUID-MEG through statistical analysis.

Results

The cohort comprised 46 patients with epilepsy (mean age, 23.7 ± 8.7 [SD] years; 29 male). McNemar χ2 test indicated no significant difference for IED detection between two systems. OPM-MEG achieved a detection accuracy of 91.3 % compared with SQUID-MEG; a Gwet's first-order agreement coefficient (AC1) of 0.892 suggested good consistency. Among 39 patients with IEDs detected by both systems, OPM-MEG demonstrated closer sensor-scalp distance (p < 0.001), higher IED amplitude (p < 0.001) and SNR (p = 0.003) compared with SQUID-MEG. At the sublobar level, OPM-MEG and SQUID-MEG exhibited nearly consistent source localization results. Among 24 patients with single dipole clusters, the average centroid distance between dipole clusters of OPM-MEG and SQUID-MEG was 12.16 ± 5.90 mm.

Conclusion

This real-world study demonstrated that OPM-MEG had comparable applicability in IED detection and source localization, compared with SQUID-MEG. Additionally, OPM-MEG performed better in terms of IED amplitude and SNR. Lower costs and user-friendly features highlight the clinical potential of OPM-MEG in epilepsy assessments.
光泵磁强计与超导量子干涉装置在脑磁图中检测和定位癫痫样放电的比较研究
基于超导量子干涉装置(SQUID)的脑磁图(MEG)在癫痫检查中具有重要的临床价值,但其成本较高。基于光泵磁强计(OPM)的MEG有望克服这些限制。本研究旨在探讨OPM-MEG和SQUID-MEG在大队列癫痫患者间期癫痫样放电(IED)检测和源定位的一致性。方法对癫痫患者进行SQUID-MEG和128通道全头皮OPM-MEG检查。通过统计分析比较OPM-MEG和SQUID-MEG的IED检测、幅度、信噪比、传感器-头皮距离和源定位结果。结果本组46例癫痫患者(平均年龄23.7±8.7 [SD]岁;29岁男性)。McNemar χ2检验表明,两种系统对IED的检出率无显著差异。与SQUID-MEG相比,OPM-MEG的检测准确率为91.3%;Gwet的一级一致系数(AC1)为0.892,表明一致性较好。在两种系统检测到的39例ied患者中,OPM-MEG显示传感器与头皮的距离更近(p <;0.001),较高的IED振幅(p <;0.001)和信噪比(p = 0.003)。在叶下水平,OPM-MEG和SQUID-MEG的源定位结果几乎一致。在24例单偶极子簇患者中,OPM-MEG与SQUID-MEG偶极子簇之间的平均质心距离为12.16±5.90 mm。结论与SQUID-MEG相比,OPM-MEG在IED检测和源定位方面具有相当的适用性。此外,OPM-MEG在IED振幅和信噪比方面表现更好。较低的成本和用户友好的特点突出了OPM-MEG在癫痫评估中的临床潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
NeuroImage
NeuroImage 医学-核医学
CiteScore
11.30
自引率
10.50%
发文量
809
审稿时长
63 days
期刊介绍: NeuroImage, a Journal of Brain Function provides a vehicle for communicating important advances in acquiring, analyzing, and modelling neuroimaging data and in applying these techniques to the study of structure-function and brain-behavior relationships. Though the emphasis is on the macroscopic level of human brain organization, meso-and microscopic neuroimaging across all species will be considered if informative for understanding the aforementioned relationships.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信