Rapid Determination of 25-Hydroxyvitamin D3 and 24,25-Dihydroxyvitamin D3 in Human Urine Based on Polystyrene/Graphene Oxide Packed-Fibers Solid-Phase Extraction Coupled With High-Performance Liquid Chromatography and Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry

IF 2.8 3区 工程技术 Q2 CHEMISTRY, ANALYTICAL
Qing Han, Min Zhou, Xuejun Kang, Guozhe Deng, Feng Guo, Li Geng
{"title":"Rapid Determination of 25-Hydroxyvitamin D3 and 24,25-Dihydroxyvitamin D3 in Human Urine Based on Polystyrene/Graphene Oxide Packed-Fibers Solid-Phase Extraction Coupled With High-Performance Liquid Chromatography and Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry","authors":"Qing Han,&nbsp;Min Zhou,&nbsp;Xuejun Kang,&nbsp;Guozhe Deng,&nbsp;Feng Guo,&nbsp;Li Geng","doi":"10.1002/jssc.70130","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>Vitamin D plays a crucial role in skeletal metabolism and is implicated in various diseases. Several studies have indicated that human vitamin D status can be evaluated through urine hydroxyvitamin D levels, in addition to plasma hydroxyvitamin D concentrations. In this study, we developed a novel method for the detection of trace amounts of 25-hydroxyvitamin D<sub>3</sub> [25(OH)D<sub>3</sub>] and 24,25-dihydroxyvitamin D<sub>3</sub> [24,25(OH)<sub>2</sub>D<sub>3</sub>] in urine. This method is based on high-performance liquid chromatography coupled with atmospheric pressure chemical ion source-tandem mass spectrometry, integrated with packed-fibers solid-phase extraction. The composite polystyrene/graphene oxide (PS/GO) nanofibers were synthesized as the sorbent for concentrating 25(OH)D<sub>3</sub> and 24,25(OH)<sub>2</sub>D<sub>3</sub>, achieving a twentyfold increase in sensitivity when analyzing human urine samples. Fourier-transform infrared spectroscopy, X-ray diffraction, and energy-dispersive X-ray spectroscopy mapping analysis were employed to characterize GO, PS, and PS/GO. The results indicated that the composite nanofibers were successfully synthesized. In addition, we investigated the relationship between the extraction performance of the fibers and the electrospinning process at varying flow rates of spinning solution through morphological studies and Brunauer-Emmett-Teller surface area analysis. During the extraction process, purification, concentration, and desorption were accomplished within a single step. The established method demonstrated excellent sensitivity and efficiency. Under optimal conditions, limits of detection (signal-to-noise ratio = 3) were found to be 0.33 ng/mL for 25(OH)D<sub>3</sub> and 0.19 ng/mL for 24,25(OH)<sub>2</sub>D<sub>3</sub>; furthermore, linearity was deemed acceptable across urine samples. Recovery rates ranged from 89.5% to 109.7% for 25(OH)D<sub>3</sub> and from 90.3% to 103.1% for 24,25(OH)<sub>2</sub>D<sub>3</sub>, respectively.</p>\n </div>","PeriodicalId":17098,"journal":{"name":"Journal of separation science","volume":"48 4","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of separation science","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jssc.70130","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Vitamin D plays a crucial role in skeletal metabolism and is implicated in various diseases. Several studies have indicated that human vitamin D status can be evaluated through urine hydroxyvitamin D levels, in addition to plasma hydroxyvitamin D concentrations. In this study, we developed a novel method for the detection of trace amounts of 25-hydroxyvitamin D3 [25(OH)D3] and 24,25-dihydroxyvitamin D3 [24,25(OH)2D3] in urine. This method is based on high-performance liquid chromatography coupled with atmospheric pressure chemical ion source-tandem mass spectrometry, integrated with packed-fibers solid-phase extraction. The composite polystyrene/graphene oxide (PS/GO) nanofibers were synthesized as the sorbent for concentrating 25(OH)D3 and 24,25(OH)2D3, achieving a twentyfold increase in sensitivity when analyzing human urine samples. Fourier-transform infrared spectroscopy, X-ray diffraction, and energy-dispersive X-ray spectroscopy mapping analysis were employed to characterize GO, PS, and PS/GO. The results indicated that the composite nanofibers were successfully synthesized. In addition, we investigated the relationship between the extraction performance of the fibers and the electrospinning process at varying flow rates of spinning solution through morphological studies and Brunauer-Emmett-Teller surface area analysis. During the extraction process, purification, concentration, and desorption were accomplished within a single step. The established method demonstrated excellent sensitivity and efficiency. Under optimal conditions, limits of detection (signal-to-noise ratio = 3) were found to be 0.33 ng/mL for 25(OH)D3 and 0.19 ng/mL for 24,25(OH)2D3; furthermore, linearity was deemed acceptable across urine samples. Recovery rates ranged from 89.5% to 109.7% for 25(OH)D3 and from 90.3% to 103.1% for 24,25(OH)2D3, respectively.

维生素 D 在骨骼代谢中起着至关重要的作用,并与多种疾病有关。一些研究表明,除了血浆中的羟基维生素 D 浓度外,还可以通过尿液中的羟基维生素 D 水平来评估人体的维生素 D 状态。在这项研究中,我们开发了一种检测尿液中痕量 25-羟基维生素 D3 [25(OH)D3] 和 24,25-二羟基维生素 D3 [24,25(OH)2D3]的新方法。该方法以高效液相色谱-常压化学离子源-串联质谱为基础,结合填充纤维固相萃取。该方法合成了聚苯乙烯/氧化石墨烯(PS/GO)复合纳米纤维,作为浓缩 25(OH)D3 和 24,25(OH)2D3的吸附剂,在分析人体尿样时灵敏度提高了 20 倍。研究人员采用傅立叶变换红外光谱、X 射线衍射和能量色散 X 射线光谱图谱分析法对 GO、PS 和 PS/GO 进行了表征。结果表明,成功合成了复合纳米纤维。此外,我们还通过形态学研究和布鲁瑙尔-艾美特-泰勒比表面积分析,研究了不同纺丝溶液流速下纤维的萃取性能与电纺丝过程之间的关系。在萃取过程中,纯化、浓缩和解吸在一个步骤内完成。所建立的方法具有出色的灵敏度和效率。在最佳条件下,25(OH)D3 的检测限(信噪比 = 3)为 0.33 纳克/毫升,24,25(OH)2D3 的检测限为 0.19 纳克/毫升。25(OH)D3 的回收率为 89.5%-109.7%,24,25(OH)2D3 的回收率为 90.3%-103.1%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of separation science
Journal of separation science 化学-分析化学
CiteScore
6.30
自引率
16.10%
发文量
408
审稿时长
1.8 months
期刊介绍: The Journal of Separation Science (JSS) is the most comprehensive source in separation science, since it covers all areas of chromatographic and electrophoretic separation methods in theory and practice, both in the analytical and in the preparative mode, solid phase extraction, sample preparation, and related techniques. Manuscripts on methodological or instrumental developments, including detection aspects, in particular mass spectrometry, as well as on innovative applications will also be published. Manuscripts on hyphenation, automation, and miniaturization are particularly welcome. Pre- and post-separation facets of a total analysis may be covered as well as the underlying logic of the development or application of a method.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信