Seokhwan Min, Seou Choi, Simo Pajovic, Sachin Vaidya, Nicholas Rivera, Shanhui Fan, Marin Soljačić, Charles Roques-Carmes
{"title":"End-to-end design of multicolor scintillators for enhanced energy resolution in X-ray imaging","authors":"Seokhwan Min, Seou Choi, Simo Pajovic, Sachin Vaidya, Nicholas Rivera, Shanhui Fan, Marin Soljačić, Charles Roques-Carmes","doi":"10.1038/s41377-025-01836-8","DOIUrl":null,"url":null,"abstract":"<p>Scintillators have been widely used in X-ray imaging due to their ability to convert high-energy radiation into visible light, making them essential for applications such as medical imaging and high-energy physics. Recent advances in the artificial structuring of scintillators offer new opportunities for improving the energy resolution of scintillator-based X-ray detectors. Here, we present a three-bin energy-resolved X-ray imaging framework based on a three-layer multicolor scintillator used in conjunction with a physics-aware image postprocessing algorithm. The multicolor scintillator is able to preserve X-ray energy information through the combination of emission wavelength multiplexing and energy-dependent isolation of X-ray absorption in specific layers. The dominant emission color and the radius of the spot measured by the detector are used to infer the incident X-ray energy based on prior knowledge of the energy-dependent absorption profiles of the scintillator stack. Through ab initio Monte Carlo simulations, we show that our approach can achieve an energy reconstruction accuracy of 49.7%, which is only 2% below the maximum accuracy achievable with realistic scintillators. We apply our framework to medical phantom imaging simulations where we demonstrate that it can effectively differentiate iodine and gadolinium-based contrast agents from bone, muscle, and soft tissue.</p>","PeriodicalId":18069,"journal":{"name":"Light-Science & Applications","volume":"39 1","pages":""},"PeriodicalIF":20.6000,"publicationDate":"2025-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Light-Science & Applications","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1038/s41377-025-01836-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0
Abstract
Scintillators have been widely used in X-ray imaging due to their ability to convert high-energy radiation into visible light, making them essential for applications such as medical imaging and high-energy physics. Recent advances in the artificial structuring of scintillators offer new opportunities for improving the energy resolution of scintillator-based X-ray detectors. Here, we present a three-bin energy-resolved X-ray imaging framework based on a three-layer multicolor scintillator used in conjunction with a physics-aware image postprocessing algorithm. The multicolor scintillator is able to preserve X-ray energy information through the combination of emission wavelength multiplexing and energy-dependent isolation of X-ray absorption in specific layers. The dominant emission color and the radius of the spot measured by the detector are used to infer the incident X-ray energy based on prior knowledge of the energy-dependent absorption profiles of the scintillator stack. Through ab initio Monte Carlo simulations, we show that our approach can achieve an energy reconstruction accuracy of 49.7%, which is only 2% below the maximum accuracy achievable with realistic scintillators. We apply our framework to medical phantom imaging simulations where we demonstrate that it can effectively differentiate iodine and gadolinium-based contrast agents from bone, muscle, and soft tissue.