Comparing the stability of implants coated with nano PLGA-alendronate sodium: an in-vivo study.

Biomaterial investigations in dentistry Pub Date : 2025-03-31 eCollection Date: 2025-01-01 DOI:10.2340/biid.v12.43372
Vahid Naemi, Abbas Haghighat, Mahla Esfahanian
{"title":"Comparing the stability of implants coated with nano PLGA-alendronate sodium: an in-vivo study.","authors":"Vahid Naemi, Abbas Haghighat, Mahla Esfahanian","doi":"10.2340/biid.v12.43372","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Considering the effect of bone resorption-inhibiting drugs, such as bisphosphonates, on bone density, the present study evaluated the stability of implants coated with polylactic-co-glycolic acid (PLGA)-alendronate sodium.</p><p><strong>Methodology: </strong>Ten healthy Swiss rabbits were selected (mean weight: 3.5 kg). Two titanium implants were inserted in each rabbit's tibia bone, one implant coated with PLGA-alendronate sodium and the other functioning as control. Torque meter equipment measured the amount of torque while inserting the implants. Insertion torque was measured during the initial insertion of the implants, and after 4 weeks, the rabbits were anesthetized again, the implants were exposed, and resistance torques were measured and recorded. Using a trephine bur, all implants and the surrounding bone structure were then removed for histological evaluation. Fourier transform infrared spectroscopy was used to investigate alendronate and PLGA biologically. Data analysis was performed using SPSS.v23 software with a significance level of <i>p</i> < 0.05.</p><p><strong>Results: </strong>The results showed that the difference between insertion torque and final resistance torque after 4 weeks was statistically significant (<i>p</i> = 0.024). The mean number of osteoclasts and macrophages differed substantially between the experimental and control groups (<i>p</i> < 0.001). The ratio of woven bone to lamellar bone and the number of osteoblasts did not differ significantly between the two groups (<i>p</i> > 0.05).</p><p><strong>Conclusion: </strong>The use of PLGA-alendronate sodium coating decreased the number of osteoclasts and macrophages and increased the stability of implant anchorage.</p>","PeriodicalId":72378,"journal":{"name":"Biomaterial investigations in dentistry","volume":"12 ","pages":"43372"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11971944/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterial investigations in dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2340/biid.v12.43372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Considering the effect of bone resorption-inhibiting drugs, such as bisphosphonates, on bone density, the present study evaluated the stability of implants coated with polylactic-co-glycolic acid (PLGA)-alendronate sodium.

Methodology: Ten healthy Swiss rabbits were selected (mean weight: 3.5 kg). Two titanium implants were inserted in each rabbit's tibia bone, one implant coated with PLGA-alendronate sodium and the other functioning as control. Torque meter equipment measured the amount of torque while inserting the implants. Insertion torque was measured during the initial insertion of the implants, and after 4 weeks, the rabbits were anesthetized again, the implants were exposed, and resistance torques were measured and recorded. Using a trephine bur, all implants and the surrounding bone structure were then removed for histological evaluation. Fourier transform infrared spectroscopy was used to investigate alendronate and PLGA biologically. Data analysis was performed using SPSS.v23 software with a significance level of p < 0.05.

Results: The results showed that the difference between insertion torque and final resistance torque after 4 weeks was statistically significant (p = 0.024). The mean number of osteoclasts and macrophages differed substantially between the experimental and control groups (p < 0.001). The ratio of woven bone to lamellar bone and the number of osteoblasts did not differ significantly between the two groups (p > 0.05).

Conclusion: The use of PLGA-alendronate sodium coating decreased the number of osteoclasts and macrophages and increased the stability of implant anchorage.

纳米plga -阿仑膦酸钠包被植入物的体内稳定性比较研究。
目的:考虑骨吸收抑制药物(如双膦酸盐)对骨密度的影响,评价聚乳酸-羟基乙酸-阿隆膦酸钠包被种植体的稳定性。方法:选择健康瑞士兔10只,平均体重3.5 kg。每只兔胫骨内置入2个钛种植体,一个种植体涂覆plga -阿仑膦酸钠,另一个作为对照。扭矩计设备测量植入植入物时的扭矩量。首次植入植入物时测量植入扭矩,4周后再次麻醉家兔,暴露植入物,测量并记录阻力扭矩。使用环钻,所有的植入物和周围的骨结构被移除进行组织学评估。傅里叶变换红外光谱对阿仑膦酸钠和PLGA进行了生物学研究。数据分析采用SPSS软件。V23软件显著性水平p < 0.05。结果:结果显示,4周后插入扭矩与最终阻力扭矩差异有统计学意义(p = 0.024)。破骨细胞和巨噬细胞的平均数量在实验组和对照组之间有显著差异(p < 0.001)。两组间编织骨与板层骨之比及成骨细胞数无显著差异(p < 0.05)。结论:plga -阿仑膦酸钠包被可减少破骨细胞和巨噬细胞数量,提高种植体支抗的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信