Evaluating Somfit's pulse arterial tonometry for detection of obstructive sleep apnoea.

IF 1 4区 医学 Q4 CLINICAL NEUROLOGY
Sleep and Biological Rhythms Pub Date : 2024-11-27 eCollection Date: 2025-04-01 DOI:10.1007/s41105-024-00559-4
Marcus McMahon, Jeremy Goldin, Elizabeth Susan Kealy, Darrel Joseph Wicks, Eugene Zilberg, Warwick Freeman, Behzad Aliahmad
{"title":"Evaluating Somfit's pulse arterial tonometry for detection of obstructive sleep apnoea.","authors":"Marcus McMahon, Jeremy Goldin, Elizabeth Susan Kealy, Darrel Joseph Wicks, Eugene Zilberg, Warwick Freeman, Behzad Aliahmad","doi":"10.1007/s41105-024-00559-4","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluates the diagnostic accuracy of Somfit against polysomnography (PSG) for detecting obstructive sleep apnoea (OSA). Somfit is a wearable home-sleep monitoring device attached to the forehead, combining pulse arterial tonometry, oximetry, and actigraphy with sleep staging, arousals, and total sleep time (TST) derived from frontal neurological signals. Ninety-two participants suspected of having OSA were assessed using Somfit and simultaneous overnight PSG recordings at three Australian sites. Each PSG study was manually scored by three independent scorers. The reported statistics include standard measures of agreement between Somfit's TST, Oxygen-Saturation Index (ODI), Apnoea-Hypopnea Index (AHI), and the average of those metrics from the three PSG scorers. The overall inter-scorer agreement was 76% (kappa = 0.772). TST, ODI, and AHI from Somfit were highly correlated with similar metrics from PSG (all r > 0.84, <i>p</i> < 0.001). Sensitivity, specificity, and accuracy were 90.5%, 75.0%, and 89.1% respectively, with a diagnostic odds ratio (DOR) of 28.5 for AHI ≥ 5. For AHI ≥ 15, sensitivity, specificity, and accuracy were 78.0%, 73.8%, and 76.1%, respectively, with a DOR of 9.99. For AHI ≥ 30, sensitivity, specificity, accuracy, and DOR were 72.4%, 90.5%, 84.8%, and 24.9, respectively. The area under the curve (AUC) at different PSG AHI cut-offs ranged between 0.86 and 0.93. Coupled with oximetry and EEG-based derivation of TST, Somfit's performance is comparable to PSG in detecting OSA severity.</p>","PeriodicalId":21896,"journal":{"name":"Sleep and Biological Rhythms","volume":"23 2","pages":"145-152"},"PeriodicalIF":1.0000,"publicationDate":"2024-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11971089/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sleep and Biological Rhythms","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s41105-024-00559-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This study evaluates the diagnostic accuracy of Somfit against polysomnography (PSG) for detecting obstructive sleep apnoea (OSA). Somfit is a wearable home-sleep monitoring device attached to the forehead, combining pulse arterial tonometry, oximetry, and actigraphy with sleep staging, arousals, and total sleep time (TST) derived from frontal neurological signals. Ninety-two participants suspected of having OSA were assessed using Somfit and simultaneous overnight PSG recordings at three Australian sites. Each PSG study was manually scored by three independent scorers. The reported statistics include standard measures of agreement between Somfit's TST, Oxygen-Saturation Index (ODI), Apnoea-Hypopnea Index (AHI), and the average of those metrics from the three PSG scorers. The overall inter-scorer agreement was 76% (kappa = 0.772). TST, ODI, and AHI from Somfit were highly correlated with similar metrics from PSG (all r > 0.84, p < 0.001). Sensitivity, specificity, and accuracy were 90.5%, 75.0%, and 89.1% respectively, with a diagnostic odds ratio (DOR) of 28.5 for AHI ≥ 5. For AHI ≥ 15, sensitivity, specificity, and accuracy were 78.0%, 73.8%, and 76.1%, respectively, with a DOR of 9.99. For AHI ≥ 30, sensitivity, specificity, accuracy, and DOR were 72.4%, 90.5%, 84.8%, and 24.9, respectively. The area under the curve (AUC) at different PSG AHI cut-offs ranged between 0.86 and 0.93. Coupled with oximetry and EEG-based derivation of TST, Somfit's performance is comparable to PSG in detecting OSA severity.

评估尚飞脉搏动脉测压仪检测阻塞性睡眠呼吸暂停的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Sleep and Biological Rhythms
Sleep and Biological Rhythms 医学-临床神经学
CiteScore
2.20
自引率
9.10%
发文量
71
审稿时长
>12 weeks
期刊介绍: Sleep and Biological Rhythms is a quarterly peer-reviewed publication dealing with medical treatments relating to sleep. The journal publishies original articles, short papers, commentaries and the occasional reviews. In scope the journal covers mechanisms of sleep and wakefullness from the ranging perspectives of basic science, medicine, dentistry, pharmacology, psychology, engineering, public health and related branches of the social sciences
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信