Minimum five years outcomes of modular dual mobility in primary total hip arthroplasty: a systematic review.

IF 2 3区 医学 Q2 ORTHOPEDICS
Marco Minelli, Elizaveta Kon, Alessio D'Addona, Marco Rosolani, Berardo Di Matteo, Federico Della Rocca
{"title":"Minimum five years outcomes of modular dual mobility in primary total hip arthroplasty: a systematic review.","authors":"Marco Minelli, Elizaveta Kon, Alessio D'Addona, Marco Rosolani, Berardo Di Matteo, Federico Della Rocca","doi":"10.1007/s00264-025-06507-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Modular dual mobility (MDM) cups are constituted by a cobalt-chromium (CoCr) liner inserted into a standard acetabular shell, allowing for intra-operative decision and supplementary screw fixation of the acetabular component. MDM could face mechanical issues and biological issues, with the associated risk of elevated blood metal ions levels and adverse local tissue reactions (ALTRs).</p><p><strong>Materials and methods: </strong>A systematic review of the literature on minimum five years outcomes of modular dual mobility in primary total hip arthroplasty (THA) was performed on PubMed, Cochrane, and Google Scholar databases, in adherence with PRISMA guidelines. Risk of bias in each study was assessed through the JBI checklist for case series.</p><p><strong>Results: </strong>A total of 381 primary THAs with MDM acetabular cup were performed. At minimum five years follow-up, mean revision rate was 2.3% and implant survivorship was 98.2%. No MDM acetabular construct was revised specifically due to liner mechanical failure, neck-rim impingement, or ALTRs. No intraprosthetic dislocation or iliopsoas tendinitis was observed. No cases of THA dislocation were reported. Mean serum metal ion levels were observed to be within laboratory reference ranges. Greater-than-normal values of serum Co were observed in 9.4% of cases, while greater-than-normal values of serum Cr were observed in 1.6% of patients.</p><p><strong>Conclusions: </strong>The main finding of this systematic review is that modular dual mobility acetabular construct appears to be a safe and effective option for primary THA at minimum five years follow-up. Longer follow-up time is needed in order to investigate modular dual mobility long-term survivorship, revision and complication rates, clinical and radiological outcomes.</p>","PeriodicalId":14450,"journal":{"name":"International Orthopaedics","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Orthopaedics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00264-025-06507-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Modular dual mobility (MDM) cups are constituted by a cobalt-chromium (CoCr) liner inserted into a standard acetabular shell, allowing for intra-operative decision and supplementary screw fixation of the acetabular component. MDM could face mechanical issues and biological issues, with the associated risk of elevated blood metal ions levels and adverse local tissue reactions (ALTRs).

Materials and methods: A systematic review of the literature on minimum five years outcomes of modular dual mobility in primary total hip arthroplasty (THA) was performed on PubMed, Cochrane, and Google Scholar databases, in adherence with PRISMA guidelines. Risk of bias in each study was assessed through the JBI checklist for case series.

Results: A total of 381 primary THAs with MDM acetabular cup were performed. At minimum five years follow-up, mean revision rate was 2.3% and implant survivorship was 98.2%. No MDM acetabular construct was revised specifically due to liner mechanical failure, neck-rim impingement, or ALTRs. No intraprosthetic dislocation or iliopsoas tendinitis was observed. No cases of THA dislocation were reported. Mean serum metal ion levels were observed to be within laboratory reference ranges. Greater-than-normal values of serum Co were observed in 9.4% of cases, while greater-than-normal values of serum Cr were observed in 1.6% of patients.

Conclusions: The main finding of this systematic review is that modular dual mobility acetabular construct appears to be a safe and effective option for primary THA at minimum five years follow-up. Longer follow-up time is needed in order to investigate modular dual mobility long-term survivorship, revision and complication rates, clinical and radiological outcomes.

求助全文
约1分钟内获得全文 求助全文
来源期刊
International Orthopaedics
International Orthopaedics 医学-整形外科
CiteScore
5.50
自引率
7.40%
发文量
360
审稿时长
1 months
期刊介绍: International Orthopaedics, the Official Journal of the Société Internationale de Chirurgie Orthopédique et de Traumatologie (SICOT) , publishes original papers from all over the world. The articles deal with clinical orthopaedic surgery or basic research directly connected with orthopaedic surgery. International Orthopaedics will also link all the members of SICOT by means of an insert that will be concerned with SICOT matters. Finally, it is expected that news and information regarding all aspects of orthopaedic surgery, including meetings, panels, instructional courses, etc. will be brought to the attention of the readers. Manuscripts submitted for publication must contain a statement to the effect that all human studies have been approved by the appropriate ethics committee and have therefore been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki. It should also be stated clearly in the text that all persons gave their informed consent prior to their inclusion in the study. Details that might disclose the identity of the subjects under study should be omitted. Reports of animal experiments must state that the "Principles of laboratory animal care" (NIH publication No. 85-23, revised 1985) were followed, as well as specific national laws (e.g. the current version of the German Law on the Protection of Animals) where applicable. The editors reserve the right to reject manuscripts that do not comply with the above-mentioned requirements. The author will be held responsible for false statements or for failure to fulfil the above-mentioned requirements.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信