{"title":"Konar-MF ™: Versatile Utility Suggests Potential to Simplify Congenital Catheterization Laboratory Inventory.","authors":"Navaneetha Sasikumar, Pranoti Toshniwal, Usha Mandikal Kondakarna Sastry, Shweta Bakhru, Jayaranganath Mahimarangaiah, Nageshwara Rao Koneti, Raman Krishna Kumar","doi":"10.1007/s00246-025-03849-x","DOIUrl":null,"url":null,"abstract":"<p><p>KONAR-MF™ device is a novel, cone-shaped, medium profile, self-expanding, double-disk, nitinol occlusive device designed for the ventricular septal defect (VSD). Due to its unique design and easy deployment from either side and multiple occlusion layers, it has also been used to occlude defects other than VSD. A retrospective review was done from 2019 to 2024 from three institutions. All patients where the KONAR-MF™ device was used other than for VSD closure were included in this study. Standard post-procedure follow-up was at 1, 6, and 12 months for all patients. 79 off-label implantations of the KONAR-MF™ device were done for conditions that included 59 shunt lesions (patent ductus arteriosus -34, coronary arteriovenous fistula -12, pulmonary arteriovenous fistula -2, systemic arteriovenous fistula -3, aortopulmonary window -3, aortopulmonary collateral -5, Fontan fenestration closures -7, Fontan antegrade pulmonary valve closures -2, Abernethy malformations -3, decompressing vein -2, and paravalvular leak -2, others 4. The median fluoroscopy time was 10 min (IQR 6-18). The median duration of hospital stay was 2 days (IQR 1-4 days). There were no significant complications. Complete occlusion at the end of the procedure was documented in 72 (91.13%) patients. At a median follow-up of 18 months (IQR 12-28 months) in all except one patient who had mild residual flow with no device-/(procedure) related complications. The unique structure and compact profile of KONAR-MF™ enable a wide range of uses in catheter-based management of various CHDs with the potential to simplify the inventory of the catheterization laboratory.</p>","PeriodicalId":19814,"journal":{"name":"Pediatric Cardiology","volume":" ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2025-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00246-025-03849-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
KONAR-MF™ device is a novel, cone-shaped, medium profile, self-expanding, double-disk, nitinol occlusive device designed for the ventricular septal defect (VSD). Due to its unique design and easy deployment from either side and multiple occlusion layers, it has also been used to occlude defects other than VSD. A retrospective review was done from 2019 to 2024 from three institutions. All patients where the KONAR-MF™ device was used other than for VSD closure were included in this study. Standard post-procedure follow-up was at 1, 6, and 12 months for all patients. 79 off-label implantations of the KONAR-MF™ device were done for conditions that included 59 shunt lesions (patent ductus arteriosus -34, coronary arteriovenous fistula -12, pulmonary arteriovenous fistula -2, systemic arteriovenous fistula -3, aortopulmonary window -3, aortopulmonary collateral -5, Fontan fenestration closures -7, Fontan antegrade pulmonary valve closures -2, Abernethy malformations -3, decompressing vein -2, and paravalvular leak -2, others 4. The median fluoroscopy time was 10 min (IQR 6-18). The median duration of hospital stay was 2 days (IQR 1-4 days). There were no significant complications. Complete occlusion at the end of the procedure was documented in 72 (91.13%) patients. At a median follow-up of 18 months (IQR 12-28 months) in all except one patient who had mild residual flow with no device-/(procedure) related complications. The unique structure and compact profile of KONAR-MF™ enable a wide range of uses in catheter-based management of various CHDs with the potential to simplify the inventory of the catheterization laboratory.
期刊介绍:
The editor of Pediatric Cardiology welcomes original manuscripts concerning all aspects of heart disease in infants, children, and adolescents, including embryology and anatomy, physiology and pharmacology, biochemistry, pathology, genetics, radiology, clinical aspects, investigative cardiology, electrophysiology and echocardiography, and cardiac surgery. Articles which may include original articles, review articles, letters to the editor etc., must be written in English and must be submitted solely to Pediatric Cardiology.