Airway Management for Tracheal Perforation After Left Hemi-Thyroid Lobectomy: A Case Report.

IF 1 Q3 MEDICINE, GENERAL & INTERNAL
Masato Ryo, Shunsaku Goto, Keiko Hamada, Yasuko Nagasaka
{"title":"Airway Management for Tracheal Perforation After Left Hemi-Thyroid Lobectomy: A Case Report.","authors":"Masato Ryo, Shunsaku Goto, Keiko Hamada, Yasuko Nagasaka","doi":"10.12659/AJCR.946437","DOIUrl":null,"url":null,"abstract":"<p><p>BACKGROUND Tracheal perforation, although rare, poses significant challenges for anesthesiologists following thyroid surgery, often necessitating complex airway management under general anesthesia. There is limited literature on effective strategies for managing airway complications in these patients. This report details a case of successful airway management using awake fiberoptic intubation in a patient with tracheal perforation and necrosis following a thyroidectomy. CASE REPORT A 65-year-old woman developed tracheal perforation 6 months after left hemi-thyroid lobectomy. She presented with symptoms of sore throat and neck swelling. Preoperative exams revealed an erosive tracheal perforation (3 cm) on the left side, immediately below the glottis. She was scheduled for an urgent tracheostomy under general anesthesia. A multidisciplinary team discussed various airway management strategies, including awake fiberoptic intubation, awake tracheostomy, and extracorporeal membrane oxygenation. Due to the adequate distance between the perforation and the tracheal bifurcation, awake fiberoptic intubation was selected. In the operating room, the bronchoscope was carefully advanced below the perforation site, and the endotracheal tube was then gently passed over the bronchoscope, ensuring the cuff did not disturb the perforation. The tube was positioned with its tip just above the tracheal bifurcation, and general anesthesia was subsequently initiated. Postoperative histological analysis of the tissue obtained during the tracheostomy revealed squamous cell carcinoma, suggesting that malignancy-related tracheal necrosis may have contributed to the perforation. CONCLUSIONS We report successful airway management in a patient with tracheal perforation following left hemi-thyroid lobectomy. Awake fiberoptic intubation proved to be an essential technique for managing such complex cases.</p>","PeriodicalId":39064,"journal":{"name":"American Journal of Case Reports","volume":"26 ","pages":"e946437"},"PeriodicalIF":1.0000,"publicationDate":"2025-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12659/AJCR.946437","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

BACKGROUND Tracheal perforation, although rare, poses significant challenges for anesthesiologists following thyroid surgery, often necessitating complex airway management under general anesthesia. There is limited literature on effective strategies for managing airway complications in these patients. This report details a case of successful airway management using awake fiberoptic intubation in a patient with tracheal perforation and necrosis following a thyroidectomy. CASE REPORT A 65-year-old woman developed tracheal perforation 6 months after left hemi-thyroid lobectomy. She presented with symptoms of sore throat and neck swelling. Preoperative exams revealed an erosive tracheal perforation (3 cm) on the left side, immediately below the glottis. She was scheduled for an urgent tracheostomy under general anesthesia. A multidisciplinary team discussed various airway management strategies, including awake fiberoptic intubation, awake tracheostomy, and extracorporeal membrane oxygenation. Due to the adequate distance between the perforation and the tracheal bifurcation, awake fiberoptic intubation was selected. In the operating room, the bronchoscope was carefully advanced below the perforation site, and the endotracheal tube was then gently passed over the bronchoscope, ensuring the cuff did not disturb the perforation. The tube was positioned with its tip just above the tracheal bifurcation, and general anesthesia was subsequently initiated. Postoperative histological analysis of the tissue obtained during the tracheostomy revealed squamous cell carcinoma, suggesting that malignancy-related tracheal necrosis may have contributed to the perforation. CONCLUSIONS We report successful airway management in a patient with tracheal perforation following left hemi-thyroid lobectomy. Awake fiberoptic intubation proved to be an essential technique for managing such complex cases.

求助全文
约1分钟内获得全文 求助全文
来源期刊
American Journal of Case Reports
American Journal of Case Reports Medicine-Medicine (all)
CiteScore
1.80
自引率
0.00%
发文量
599
期刊介绍: American Journal of Case Reports is an international, peer-reviewed scientific journal that publishes single and series case reports in all medical fields. American Journal of Case Reports is issued on a continuous basis as a primary electronic journal. Print copies of a single article or a set of articles can be ordered on demand.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信