A Cross-Sectional Study on Comparison of Serum Cortisol Concentration Measured by Chemiluminescent Immunoassay in Four Different Automated Analyzers in a Variety of Adrenal Disorders.

Neeti Agrawal, Anirban Sinha, Partha P Chakraborty, Rana Bhattacharjee, Avivar Awasthi, Animesh Maiti
{"title":"A Cross-Sectional Study on Comparison of Serum Cortisol Concentration Measured by Chemiluminescent Immunoassay in Four Different Automated Analyzers in a Variety of Adrenal Disorders.","authors":"Neeti Agrawal, Anirban Sinha, Partha P Chakraborty, Rana Bhattacharjee, Avivar Awasthi, Animesh Maiti","doi":"10.4103/ijem.ijem_482_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Cortisol concentration is often estimated by competitive chemiluminescent immunoassays, which are prone to interference due to cross-reactivity. The extent of interference is inconsistent across different adrenal disorders and among different analyzers. Although liquid chromatography-mass spectrometry (LC-MS/MS) possesses better analytical specificity, it is not widely available. We aimed to compare cortisol values measured across four different analyzers across different adrenal disorders.</p><p><strong>Methods: </strong>Cortisol concentrations were measured in the serum of patients with congenital adrenal hyperplasia (CAH) (<i>n</i> = 12), primary adrenal insufficiency (PAI) (<i>n</i> = 11), endogenous Cushing's syndrome (CS) (<i>n</i> = 6), adrenal incidentaloma (AI) (<i>n</i> = 8), and healthy subjects (HS) (<i>n</i> = 10) in the following analyzers: Advia Centaur XP (Siemens) (SACXP), Immulite1000 (Siemens) (SI1000), Cobas e411 (Roche) (RCe411), and Architect (Abbott)(AA).</p><p><strong>Results: </strong>In CAH patients, a poor agreement was observed between SAC XP [median (IQR) 14.6 (4.7) μg/dL] and RC e411 [median (IQR) 4.6 (3.9) μg/dL] [ICC: -0.016, (-0.55, 0.55)]. The correlation was also poor between SAC XP and SI 1000 [ICC: 0.00, (0.558, 0.551)] as well as between SAC XP and AA [ICC: 0.089, (-0.488, 0.612)]. The agreement was good between RCe411, SI 1000 [median (IQR) 9.6 (3) μg/dL], and AA [median (IQR) 5.1 (3.4) μg/dL] platforms in the same group. Measured cortisol values correlated well across all analyzers in PAI, CS, AI, and HS.</p><p><strong>Conclusions: </strong>Cortisol concentration demonstrated variable agreement among different analyzers in different adrenal disorders. In CAH, cortisol values measured by SAC XP poorly correlate with RC e411, SI 1000, and AA platforms. Reassessment in another analyzer therefore would be prudent to avoid devastating consequences of unrecognized hypocortisolism in this subset of patients. A good concordance was observed among platforms in other conditions.</p>","PeriodicalId":13353,"journal":{"name":"Indian Journal of Endocrinology and Metabolism","volume":"29 1","pages":"83-88"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11964372/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Endocrinology and Metabolism","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ijem.ijem_482_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/28 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Cortisol concentration is often estimated by competitive chemiluminescent immunoassays, which are prone to interference due to cross-reactivity. The extent of interference is inconsistent across different adrenal disorders and among different analyzers. Although liquid chromatography-mass spectrometry (LC-MS/MS) possesses better analytical specificity, it is not widely available. We aimed to compare cortisol values measured across four different analyzers across different adrenal disorders.

Methods: Cortisol concentrations were measured in the serum of patients with congenital adrenal hyperplasia (CAH) (n = 12), primary adrenal insufficiency (PAI) (n = 11), endogenous Cushing's syndrome (CS) (n = 6), adrenal incidentaloma (AI) (n = 8), and healthy subjects (HS) (n = 10) in the following analyzers: Advia Centaur XP (Siemens) (SACXP), Immulite1000 (Siemens) (SI1000), Cobas e411 (Roche) (RCe411), and Architect (Abbott)(AA).

Results: In CAH patients, a poor agreement was observed between SAC XP [median (IQR) 14.6 (4.7) μg/dL] and RC e411 [median (IQR) 4.6 (3.9) μg/dL] [ICC: -0.016, (-0.55, 0.55)]. The correlation was also poor between SAC XP and SI 1000 [ICC: 0.00, (0.558, 0.551)] as well as between SAC XP and AA [ICC: 0.089, (-0.488, 0.612)]. The agreement was good between RCe411, SI 1000 [median (IQR) 9.6 (3) μg/dL], and AA [median (IQR) 5.1 (3.4) μg/dL] platforms in the same group. Measured cortisol values correlated well across all analyzers in PAI, CS, AI, and HS.

Conclusions: Cortisol concentration demonstrated variable agreement among different analyzers in different adrenal disorders. In CAH, cortisol values measured by SAC XP poorly correlate with RC e411, SI 1000, and AA platforms. Reassessment in another analyzer therefore would be prudent to avoid devastating consequences of unrecognized hypocortisolism in this subset of patients. A good concordance was observed among platforms in other conditions.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Indian Journal of Endocrinology and Metabolism
Indian Journal of Endocrinology and Metabolism Medicine-Endocrinology, Diabetes and Metabolism
CiteScore
2.10
自引率
0.00%
发文量
75
期刊介绍: The Indian Journal of Endocrinology and Metabolism (IJEM) aims to function as the global face of Indian endocrinology research. It aims to act as a bridge between global and national advances in this field. The journal publishes thought-provoking editorials, comprehensive reviews, cutting-edge original research, focused brief communications and insightful letters to editor. The journal encourages authors to submit articles addressing aspects of science related to Endocrinology and Metabolism in particular Diabetology. Articles related to Clinical and Tropical endocrinology are especially encouraged. Sub-topic based Supplements are published regularly. This allows the journal to highlight issues relevant to Endocrine practitioners working in India as well as other countries. IJEM is free access in the true sense of the word, (it charges neither authors nor readers) and this enhances its global appeal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信