{"title":"Evaluation of Image Clarity in Smartglass-Supported Dynamic Computer-Assisted Implant Surgery: A Clinical Pilot Trial.","authors":"Poyuan Hsueh, Yoko Yamaguchi, Yiwen Wang, Takao Kasahara, Daisuke Higuchi, Yasutomo Yajima","doi":"10.1111/clr.14442","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study evaluated the image quality of smartglass-supported Dynamic Computer-Assisted Implant Surgery (dCAIS) by testing discernibility with a Landolt ring chart reproduced with smartglasses and on the dCAIS monitor.</p><p><strong>Materials and methods: </strong>15 participants' discernibility was measured under four conditions using Landolt rings. Each condition measured 13 visual acuity levels, with each level comprising three rings (39 rings per condition). Under Condition 1 (control), rings were reproduced on the dCAIS monitor and viewed without smartglasses; under Condition 2, rings were reproduced on the monitor and viewed through smartglasses; under Condition 3, rings on smartglasses matched the size on monitor; and under Condition 4, rings reproduced on smartglasses filled the field of view. Visual acuity values were converted to logarithmic values and analyzed using repeated measures ANOVA.</p><p><strong>Conclusions: </strong>Smartglasses enhance dCAIS functionality and reproducing information at the maximum perceived size achievable with smartglasses has a similar effect to visual enhancement through magnification.</p>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":" ","pages":""},"PeriodicalIF":4.8000,"publicationDate":"2025-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Implants Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/clr.14442","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: This study evaluated the image quality of smartglass-supported Dynamic Computer-Assisted Implant Surgery (dCAIS) by testing discernibility with a Landolt ring chart reproduced with smartglasses and on the dCAIS monitor.
Materials and methods: 15 participants' discernibility was measured under four conditions using Landolt rings. Each condition measured 13 visual acuity levels, with each level comprising three rings (39 rings per condition). Under Condition 1 (control), rings were reproduced on the dCAIS monitor and viewed without smartglasses; under Condition 2, rings were reproduced on the monitor and viewed through smartglasses; under Condition 3, rings on smartglasses matched the size on monitor; and under Condition 4, rings reproduced on smartglasses filled the field of view. Visual acuity values were converted to logarithmic values and analyzed using repeated measures ANOVA.
Conclusions: Smartglasses enhance dCAIS functionality and reproducing information at the maximum perceived size achievable with smartglasses has a similar effect to visual enhancement through magnification.
期刊介绍:
Clinical Oral Implants Research conveys scientific progress in the field of implant dentistry and its related areas to clinicians, teachers and researchers concerned with the application of this information for the benefit of patients in need of oral implants. The journal addresses itself to clinicians, general practitioners, periodontists, oral and maxillofacial surgeons and prosthodontists, as well as to teachers, academicians and scholars involved in the education of professionals and in the scientific promotion of the field of implant dentistry.