Optimizing axial length estimation for intraocular lens power calculation in phacovitrectomy for macula-off retinal detachment.

IF 1.9 Q2 OPHTHALMOLOGY
Sukhum Silpa-Archa, Chitchanok Samanwongthai, Variya Nganthavee, Korawin Charoensuk
{"title":"Optimizing axial length estimation for intraocular lens power calculation in phacovitrectomy for macula-off retinal detachment.","authors":"Sukhum Silpa-Archa, Chitchanok Samanwongthai, Variya Nganthavee, Korawin Charoensuk","doi":"10.1186/s40942-025-00666-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To evaluate methods of preoperative axial length (AL) estimation for intraocular lens (IOL) power calculation in patients with macula-off rhegmatogenous retinal detachment (RRD). These methods included optical biometry, A-scan biometry, and novel decision algorithms.</p><p><strong>Methods: </strong>A retrospective analysis of prospectively collected data was conducted at a tertiary hospital from January 2018 to December 2023. Preoperative and postoperative AL measurements were obtained using optical biometry (IOL Master 700, Zeiss, Germany) and A-scan biometry (VuMAX, Sonomed, USA). The primary outcome was the mean absolute prediction error (MAE) between postoperative AL and preoperative estimates generated by five methods, including two novel algorithms.</p><p><strong>Results: </strong>The study included 56 patients (56 eyes). The lowest MAE was achieved using the simple algorithm (0.31 ± 0.55 mm), followed by the AL of the fellow eye measured via IOL Master (0.34 ± 0.60 mm), and the advanced algorithm (0.36 ± 0.62 mm). A Kruskal-Wallis H test found no statistically significant difference in MAE across the five methods (P = 0.118). Bland-Altman analysis demonstrated good agreement between preoperative and postoperative AL measurements obtained with the IOL Master.</p><p><strong>Conclusion: </strong>For patients undergoing phacovitrectomy for macula-off RRD, the simple algorithm provides accurate AL estimation for IOL power calculation. In cases where AL measurement of the affected eye is not feasible using the IOL Master, the fellow eye's AL is a reliable alternative.</p>","PeriodicalId":14289,"journal":{"name":"International Journal of Retina and Vitreous","volume":"11 1","pages":"39"},"PeriodicalIF":1.9000,"publicationDate":"2025-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11967035/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Retina and Vitreous","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40942-025-00666-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: To evaluate methods of preoperative axial length (AL) estimation for intraocular lens (IOL) power calculation in patients with macula-off rhegmatogenous retinal detachment (RRD). These methods included optical biometry, A-scan biometry, and novel decision algorithms.

Methods: A retrospective analysis of prospectively collected data was conducted at a tertiary hospital from January 2018 to December 2023. Preoperative and postoperative AL measurements were obtained using optical biometry (IOL Master 700, Zeiss, Germany) and A-scan biometry (VuMAX, Sonomed, USA). The primary outcome was the mean absolute prediction error (MAE) between postoperative AL and preoperative estimates generated by five methods, including two novel algorithms.

Results: The study included 56 patients (56 eyes). The lowest MAE was achieved using the simple algorithm (0.31 ± 0.55 mm), followed by the AL of the fellow eye measured via IOL Master (0.34 ± 0.60 mm), and the advanced algorithm (0.36 ± 0.62 mm). A Kruskal-Wallis H test found no statistically significant difference in MAE across the five methods (P = 0.118). Bland-Altman analysis demonstrated good agreement between preoperative and postoperative AL measurements obtained with the IOL Master.

Conclusion: For patients undergoing phacovitrectomy for macula-off RRD, the simple algorithm provides accurate AL estimation for IOL power calculation. In cases where AL measurement of the affected eye is not feasible using the IOL Master, the fellow eye's AL is a reliable alternative.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
4.30%
发文量
81
审稿时长
19 weeks
期刊介绍: International Journal of Retina and Vitreous focuses on the ophthalmic subspecialty of vitreoretinal disorders. The journal presents original articles on new approaches to diagnosis, outcomes of clinical trials, innovations in pharmacological therapy and surgical techniques, as well as basic science advances that impact clinical practice. Topical areas include, but are not limited to: -Imaging of the retina, choroid and vitreous -Innovations in optical coherence tomography (OCT) -Small-gauge vitrectomy, retinal detachment, chromovitrectomy -Electroretinography (ERG), microperimetry, other functional tests -Intraocular tumors -Retinal pharmacotherapy & drug delivery -Diabetic retinopathy & other vascular diseases -Age-related macular degeneration (AMD) & other macular entities
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信