{"title":"Automated landmark-based symmetric and standard alignment of skull base structures on CT","authors":"Justin A. Cramer ,&nbsp;Trevor Huff ,&nbsp;Sean Kelly ,&nbsp;Daniel Welch ,&nbsp;Devin DeLuna ,&nbsp;Conner Beyersdorf ,&nbsp;Robin High ,&nbsp;Matthew White","doi":"10.1016/j.ynirp.2025.100260","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Symmetry and standard alignment are crucial in both clinical interpretation and research on head CT studies. Registration to a standard template is the traditional method for alignment, yet registration does not guarantee precise alignment of any given structure. This study introduces a method for aligning skull base structures while still achieving a standard anterior commissure-posterior commissure (AC-PC)-like orientation on head CT studies using landmarks, specifically the cochleas and nasal bridge.</div></div><div><h3>Methods</h3><div>A retrospective study was conducted using head CTs from various General Electric scanners. Landmarks were manually annotated, and a 3D U-Net was trained for landmark identification. Landmark-based alignment was then performed on a test dataset and assessed in two different ways: whole head and skull base alignment. Whole head alignment was assessed quantitatively by expert review. Skull base alignment was then assessed at the cochleas, comparing their alignment between this landmark-based technique and registration to a template.</div></div><div><h3>Results</h3><div>This landmark-based technique significantly improved whole head and skull base alignment of head CT studies. Whole head alignment reduced average deviations of 5, 11, and 4° in the axial, sagittal, and coronal planes to 1, 5, and 2° respectively. Meanwhile, skull base alignment assessed via the cochlea was also improved relative to traditional registration. For the landmark technique, the cochleas were deviated from perfect by a mean of 0.552 and 0.511 mm along the y and z axes compared to 2.110 and 2.506 mm with registration.</div></div><div><h3>Conclusion</h3><div>This study demonstrates a simple landmark-based technique for aligning the cochleas on head CT studies while approximating whole head AC-PC orientation, which has applications in both clinical and research settings, particularly for studies focused on the skull base.</div></div>","PeriodicalId":74277,"journal":{"name":"Neuroimage. Reports","volume":"5 2","pages":"Article 100260"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neuroimage. Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666956025000285","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Neuroscience","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Symmetry and standard alignment are crucial in both clinical interpretation and research on head CT studies. Registration to a standard template is the traditional method for alignment, yet registration does not guarantee precise alignment of any given structure. This study introduces a method for aligning skull base structures while still achieving a standard anterior commissure-posterior commissure (AC-PC)-like orientation on head CT studies using landmarks, specifically the cochleas and nasal bridge.

Methods

A retrospective study was conducted using head CTs from various General Electric scanners. Landmarks were manually annotated, and a 3D U-Net was trained for landmark identification. Landmark-based alignment was then performed on a test dataset and assessed in two different ways: whole head and skull base alignment. Whole head alignment was assessed quantitatively by expert review. Skull base alignment was then assessed at the cochleas, comparing their alignment between this landmark-based technique and registration to a template.

Results

This landmark-based technique significantly improved whole head and skull base alignment of head CT studies. Whole head alignment reduced average deviations of 5, 11, and 4° in the axial, sagittal, and coronal planes to 1, 5, and 2° respectively. Meanwhile, skull base alignment assessed via the cochlea was also improved relative to traditional registration. For the landmark technique, the cochleas were deviated from perfect by a mean of 0.552 and 0.511 mm along the y and z axes compared to 2.110 and 2.506 mm with registration.

Conclusion

This study demonstrates a simple landmark-based technique for aligning the cochleas on head CT studies while approximating whole head AC-PC orientation, which has applications in both clinical and research settings, particularly for studies focused on the skull base.
基于地标的颅底结构在CT上的对称和标准自动对齐
对称和标准对齐在临床解释和头部CT研究中都是至关重要的。注册到标准模板是传统的对齐方法,但是注册不能保证任何给定结构的精确对齐。本研究介绍了一种对齐颅底结构的方法,同时在头部CT研究中使用地标,特别是耳蜗和鼻桥,仍能获得标准的前交合-后连合(AC-PC)样方向。方法采用不同型号通用电气扫描仪的头部ct进行回顾性研究。人工标注地标,并训练三维U-Net进行地标识别。然后在测试数据集上执行基于地标的校准,并以两种不同的方式进行评估:整个头部和颅底校准。通过专家评审对全头对准进行定量评价。然后在耳蜗上评估颅底对齐,比较这种基于地标的技术和模板注册之间的对齐。结果这种基于地标的技术显著改善了头部CT研究的全头和颅底对齐。整个头部对准将轴位、矢状面和冠状面的平均偏差分别减少了5°、11°和4°,分别减少到1°、5°和2°。同时,通过耳蜗评估的颅底对齐也比传统的配准得到了改进。与配准法的2.110和2.506 mm相比,标记法的耳蜗沿y轴和z轴偏离完美的平均值分别为0.552和0.511 mm。本研究展示了一种简单的基于地标的技术,可以在头部CT研究中对准耳蜗,同时接近整个头部的AC-PC方向,这在临床和研究环境中都有应用,特别是在颅底的研究中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Neuroimage. Reports
Neuroimage. Reports Neuroscience (General)
CiteScore
1.90
自引率
0.00%
发文量
0
审稿时长
87 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信