Impact of Extrinsic Staining on the Physical Properties Oof Provisional Resins Fabricated by Digital and Conventional Methods - An In Situ Study.

Pedro Roberto Braz Rodrigues, Ana Lucia Caetano Pereira, Rocio Geng Vivanco, Fernanda de Carvalho Panzeri
{"title":"Impact of Extrinsic Staining on the Physical Properties Oof Provisional Resins Fabricated by Digital and Conventional Methods - An In Situ Study.","authors":"Pedro Roberto Braz Rodrigues, Ana Lucia Caetano Pereira, Rocio Geng Vivanco, Fernanda de Carvalho Panzeri","doi":"10.11607/ijp.9263","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate, in situ, the color stability of a printed resin (PR), milled resin (MR), and bisacrylic resin (BR) after exposure to coffee and cigarette smoke.</p><p><strong>Materials and methods: </strong>Twelve participants per group (Control, coffee consumers, and smokers) used intraoral devices containing the specimens resins. Seventy-two samples of each resin were prepared, and initial surface roughness and color readings recorded. Participants wore the device, containing two samples of each resin, for 15 days, brushing three times per day. Final color and surface roughness measurements were obtained. Water sorption and solubility analyses were conducted (n=20). Data were analyzed using ANOVA and Tukey tests (α=0.05).</p><p><strong>Results: </strong>BR had the highest alterations in surface roughness under control conditions and after cigarette smoke exposure (p<0.05). PR showed the highest surface roughness and MR the lowest alteration after coffee consumption (p<0.05). After coffee consumption, BR exhibited higher color change than PR (p<0.05); and following cigarette smoke exposure, BR showed the highest alteration (p<0.05), while MR had the lowest (p<0.05). Cigarette smoke caused the highest color change across all resins. BR exhibited highest water sorption and solubility (p<0.05).</p><p><strong>Conclusion: </strong>Printed and milled resins demonstrated better color stability and less alteration in surface roughness change compared to bis-acrylic resin.</p><p><strong>Clinical significance: </strong>The results suggest that clinicians may achieve better esthetic outcomes by opting for digital methods, especially in patients exposed to common staining agents like coffee and cigarette smoke.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"1-20"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.9263","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate, in situ, the color stability of a printed resin (PR), milled resin (MR), and bisacrylic resin (BR) after exposure to coffee and cigarette smoke.

Materials and methods: Twelve participants per group (Control, coffee consumers, and smokers) used intraoral devices containing the specimens resins. Seventy-two samples of each resin were prepared, and initial surface roughness and color readings recorded. Participants wore the device, containing two samples of each resin, for 15 days, brushing three times per day. Final color and surface roughness measurements were obtained. Water sorption and solubility analyses were conducted (n=20). Data were analyzed using ANOVA and Tukey tests (α=0.05).

Results: BR had the highest alterations in surface roughness under control conditions and after cigarette smoke exposure (p<0.05). PR showed the highest surface roughness and MR the lowest alteration after coffee consumption (p<0.05). After coffee consumption, BR exhibited higher color change than PR (p<0.05); and following cigarette smoke exposure, BR showed the highest alteration (p<0.05), while MR had the lowest (p<0.05). Cigarette smoke caused the highest color change across all resins. BR exhibited highest water sorption and solubility (p<0.05).

Conclusion: Printed and milled resins demonstrated better color stability and less alteration in surface roughness change compared to bis-acrylic resin.

Clinical significance: The results suggest that clinicians may achieve better esthetic outcomes by opting for digital methods, especially in patients exposed to common staining agents like coffee and cigarette smoke.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信