Effect of active middle ear implant on auditory speech perception in individuals with ear malformation.

IF 0.9 Q4 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
CoDAS Pub Date : 2025-03-31 eCollection Date: 2025-01-01 DOI:10.1590/2317-1782/e20240032pt
Eliane Aparecida Techi Catisquini, Mylena Malavazi Teixeira, Cláudia Daniele Pelanda Zampronio, Jerusa Roberta Massola Oliveira, Maria Fernanda Capoani Garcia Mondelli, Luiz Fernando Manzoni Lourençone, Rubens Vuono de Brito Neto
{"title":"Effect of active middle ear implant on auditory speech perception in individuals with ear malformation.","authors":"Eliane Aparecida Techi Catisquini, Mylena Malavazi Teixeira, Cláudia Daniele Pelanda Zampronio, Jerusa Roberta Massola Oliveira, Maria Fernanda Capoani Garcia Mondelli, Luiz Fernando Manzoni Lourençone, Rubens Vuono de Brito Neto","doi":"10.1590/2317-1782/e20240032pt","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To verify the results of active middle ear implant on audibility and auditory speech perception in individuals with external and/or middle ear malformations.</p><p><strong>Methods: </strong>Primary, observational, retrospective study, through analysis of medical records of individuals with bilateral external and/or middle ear malformations, unilateral users of active middle ear implant. The data collected refer to auditory thresholds obtained through free-field audiometry and assessment of auditory speech perception - sentence recognition in silence and noise, in the following situations: without the implant, at the time of activation, in the first and in the third month of use.</p><p><strong>Results: </strong>Nine individuals were included in the study. The average age at the time of activation was 24.6 years (minimum 12 and maximum 40 years). Statistically significant improvement in auditory thresholds (p<0.05) and in the sentence recognition test in silence and noise (p<0.05) was observed at the time of activation. There was no significant difference between the evaluation situations after activation, indicating acclimatization by the user.</p><p><strong>Conclusion: </strong>The results of the active middle ear implant VSB (MED-EL) users on the audibility and auditory speech perception, in individual with external and/or middle ear malformation were better in the activation condition compared to the pre-surgical condition, maintaining stable over time; which reinforces its indication for this population.</p>","PeriodicalId":46547,"journal":{"name":"CoDAS","volume":"37 3","pages":"e20240032"},"PeriodicalIF":0.9000,"publicationDate":"2025-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11963885/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CoDAS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/2317-1782/e20240032pt","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To verify the results of active middle ear implant on audibility and auditory speech perception in individuals with external and/or middle ear malformations.

Methods: Primary, observational, retrospective study, through analysis of medical records of individuals with bilateral external and/or middle ear malformations, unilateral users of active middle ear implant. The data collected refer to auditory thresholds obtained through free-field audiometry and assessment of auditory speech perception - sentence recognition in silence and noise, in the following situations: without the implant, at the time of activation, in the first and in the third month of use.

Results: Nine individuals were included in the study. The average age at the time of activation was 24.6 years (minimum 12 and maximum 40 years). Statistically significant improvement in auditory thresholds (p<0.05) and in the sentence recognition test in silence and noise (p<0.05) was observed at the time of activation. There was no significant difference between the evaluation situations after activation, indicating acclimatization by the user.

Conclusion: The results of the active middle ear implant VSB (MED-EL) users on the audibility and auditory speech perception, in individual with external and/or middle ear malformation were better in the activation condition compared to the pre-surgical condition, maintaining stable over time; which reinforces its indication for this population.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CoDAS
CoDAS AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-
CiteScore
0.90
自引率
12.50%
发文量
103
审稿时长
30 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信