Robot-assisted partial nephrectomy and robot-assisted radical prostatectomy using the Chinese surgical systems KangDuo-SR-2000 and EDGE MP1000 versus the Da Vinci Xi system: a prospective, single-center, non-randomized clinical trial.
{"title":"Robot-assisted partial nephrectomy and robot-assisted radical prostatectomy using the Chinese surgical systems KangDuo-SR-2000 and EDGE MP1000 versus the Da Vinci Xi system: a prospective, single-center, non-randomized clinical trial.","authors":"Pengyu Guo, Honglei Wang, Zixing Wang, Tao Xu, Jianzhang Li, Yangyang Xu, Dexin Ding, Changfu Li, Lichen Teng, Hui Chen, Yongsheng Chen, Zhongjie Qiao, Muyang Cao, Chen Du, Hongwei Li, Ziqi Wang, Wanhai Xu","doi":"10.1007/s00345-025-05593-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aims to compare the safety and efficacy of robot-assisted partial nephrectomy (RAPN) and robot-assisted radical prostatectomy (RARP) using the Chinese surgical systems KangDuo-SR-2000 (KD-SR-2000) and EDGE MP1000 (MP1000) versus the Da Vinci Xi (DV-Xi) system, to explore viable alternative options to DV-Xi.</p><p><strong>Methods: </strong>This prospective, single-center, non-randomized clinical trial enrolled 261 patients who underwent RAPN or RARP from August 2023 to June 2024. All surgeries were performed by 3 surgeons. For RAPN, the primary outcome included surgical success, positive surgical margin (PSM), warm ischemia time (WIT) and conversion to open or laparoscopic surgery. The secondary outcome was estimated glomerular filtration rate (eGFR). For RARP, the primary outcome was surgical success without conversion to open or laparoscopic surgery, and the secondary outcomes included PSM and urinary continence recovery at 4 weeks post-catheter removal.</p><p><strong>Results: </strong>Baseline demographics were comparable across the KD-SR-2000 group (n = 88), EDGE MP1000 group (n = 59) and DV-Xi group (n = 114). No significant differences observed in primary and secondary outcomes. However, operation time and suture time per stitch were longer in Chinese surgical systems for both RAPN and RARP compared to DV-Xi, and estimated blood loss (EBL) is higher in RAPN. Subgroup analyses indicated that performance differences were primarily attributed to the KD-SR-2000, with no significant differences observed between the MP1000 and DV-Xi. No severe complications (Clavien-Dindo grade ≥ 3) reported in any group.</p><p><strong>Conclusions: </strong>Chinese surgical systems provide a viable alternative, demonstrating non-inferiority compared to DV-Xi.</p><p><strong>Trial registration number: </strong>ChiCTR2300074914; Registration Date: 2023-08-21.</p>","PeriodicalId":23954,"journal":{"name":"World Journal of Urology","volume":"43 1","pages":"205"},"PeriodicalIF":2.8000,"publicationDate":"2025-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00345-025-05593-6","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study aims to compare the safety and efficacy of robot-assisted partial nephrectomy (RAPN) and robot-assisted radical prostatectomy (RARP) using the Chinese surgical systems KangDuo-SR-2000 (KD-SR-2000) and EDGE MP1000 (MP1000) versus the Da Vinci Xi (DV-Xi) system, to explore viable alternative options to DV-Xi.
Methods: This prospective, single-center, non-randomized clinical trial enrolled 261 patients who underwent RAPN or RARP from August 2023 to June 2024. All surgeries were performed by 3 surgeons. For RAPN, the primary outcome included surgical success, positive surgical margin (PSM), warm ischemia time (WIT) and conversion to open or laparoscopic surgery. The secondary outcome was estimated glomerular filtration rate (eGFR). For RARP, the primary outcome was surgical success without conversion to open or laparoscopic surgery, and the secondary outcomes included PSM and urinary continence recovery at 4 weeks post-catheter removal.
Results: Baseline demographics were comparable across the KD-SR-2000 group (n = 88), EDGE MP1000 group (n = 59) and DV-Xi group (n = 114). No significant differences observed in primary and secondary outcomes. However, operation time and suture time per stitch were longer in Chinese surgical systems for both RAPN and RARP compared to DV-Xi, and estimated blood loss (EBL) is higher in RAPN. Subgroup analyses indicated that performance differences were primarily attributed to the KD-SR-2000, with no significant differences observed between the MP1000 and DV-Xi. No severe complications (Clavien-Dindo grade ≥ 3) reported in any group.
Conclusions: Chinese surgical systems provide a viable alternative, demonstrating non-inferiority compared to DV-Xi.
期刊介绍:
The WORLD JOURNAL OF UROLOGY conveys regularly the essential results of urological research and their practical and clinical relevance to a broad audience of urologists in research and clinical practice. In order to guarantee a balanced program, articles are published to reflect the developments in all fields of urology on an internationally advanced level. Each issue treats a main topic in review articles of invited international experts. Free papers are unrelated articles to the main topic.