Investigating the influence of infill pattern and layer height on the mechanical and bonding behavior of additively manufactured PEEK for dental applications.
Almira Ada Diken Türksayar, Sandra Schulnig, Sebastian Spintzyk, İrem Beril Yeşil Kurt
{"title":"Investigating the influence of infill pattern and layer height on the mechanical and bonding behavior of additively manufactured PEEK for dental applications.","authors":"Almira Ada Diken Türksayar, Sandra Schulnig, Sebastian Spintzyk, İrem Beril Yeşil Kurt","doi":"10.1016/j.prosdent.2025.03.010","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>Current knowledge regarding the influence of infill pattern and layer height on the flexural and shear bond strength of polyetheretherketone (PEEK) manufactured via fused filament fabrication technology remains limited.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to investigate the impact of infill pattern and layer height on the shear bond strength (SBS) and the flexural strength (FS) of additively manufactured PEEK bars and disks relevant to dental applications.</p><p><strong>Material and methods: </strong>The PEEK specimens were prepared in 9 groups (n=10), whereby different layer heights (0.1, 0.2, and 0.3 mm) and different infill patterns (±30, ±45 lines, concentric) were used. The surface roughness (Ra) was recorded with a confocal microscope. For the SBS test, resin composites were applied on the disk surface. All the specimens were subjected to thermal aging. The SBS and FS test was performed through a universal testing device. Two-way ANOVA, 1-way ANOVA, post hoc Tukey, and Tamhane tests were used for statistical analysis. (α=.05) RESULTS: The highest SBS values were observed at a layer height of 0.1 mm. The infill pattern had a significant effect on FS at all layer heights (0.1 mm P=.016, 0.2 mm P=.010, 0.3 mm P=.010). While the highest FS values at a 0.1-mm layer height were observed in the concentric pattern, no significant difference was identified between the L45 and L30 groups (P=.186).</p><p><strong>Conclusions: </strong>Lower layer heights strongly influenced the Ra, SBS and FS, with the highest SBS achieved with a layer height of 0.1 mm. To improve the mechanical properties of PEEK, the process parameters for additive manufacturing should be optimized.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2025.03.010","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Statement of problem: Current knowledge regarding the influence of infill pattern and layer height on the flexural and shear bond strength of polyetheretherketone (PEEK) manufactured via fused filament fabrication technology remains limited.
Purpose: The purpose of this in vitro study was to investigate the impact of infill pattern and layer height on the shear bond strength (SBS) and the flexural strength (FS) of additively manufactured PEEK bars and disks relevant to dental applications.
Material and methods: The PEEK specimens were prepared in 9 groups (n=10), whereby different layer heights (0.1, 0.2, and 0.3 mm) and different infill patterns (±30, ±45 lines, concentric) were used. The surface roughness (Ra) was recorded with a confocal microscope. For the SBS test, resin composites were applied on the disk surface. All the specimens were subjected to thermal aging. The SBS and FS test was performed through a universal testing device. Two-way ANOVA, 1-way ANOVA, post hoc Tukey, and Tamhane tests were used for statistical analysis. (α=.05) RESULTS: The highest SBS values were observed at a layer height of 0.1 mm. The infill pattern had a significant effect on FS at all layer heights (0.1 mm P=.016, 0.2 mm P=.010, 0.3 mm P=.010). While the highest FS values at a 0.1-mm layer height were observed in the concentric pattern, no significant difference was identified between the L45 and L30 groups (P=.186).
Conclusions: Lower layer heights strongly influenced the Ra, SBS and FS, with the highest SBS achieved with a layer height of 0.1 mm. To improve the mechanical properties of PEEK, the process parameters for additive manufacturing should be optimized.
期刊介绍:
The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.