Accuracy of complete arch nonsplinting and noncalibrated splinting implant scanning techniques recorded by using five intraoral scanners.

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Marta Revilla-León, Rocio Cascos, Ghida Lawand, Abdul B Barmak, John C Kois, Miguel Gómez-Polo
{"title":"Accuracy of complete arch nonsplinting and noncalibrated splinting implant scanning techniques recorded by using five intraoral scanners.","authors":"Marta Revilla-León, Rocio Cascos, Ghida Lawand, Abdul B Barmak, John C Kois, Miguel Gómez-Polo","doi":"10.1016/j.prosdent.2025.02.062","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>Splinting implant scan bodies (ISBs) has been reported to improve the accuracy of intraoral scanners (IOSs) compared with nonsplinting methods. However, the accuracy of commercially available horizontal noncalibrated ISBs remains unknown.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to compare the accuracy of complete arch scans obtained using horizontal noncalibrated or standard ISBs recorded by using 5 different IOSs.</p><p><strong>Material and methods: </strong>An edentulous maxillary stone cast with 6 implant abutment analogs (MultiUnit Abutment Plus Replica) was used. The reference scan was obtained by digitizing the reference cast with a calibrated laboratory scanner (T710). Five groups were created based on the IOS tested: TRIOS 5, i700, Primescan, Aoralscan 3, and iTero. Two subgroups were defined based on the ISBs selected to record complete arch implant scans: standard ISBs (Stand subgroup) or horizontal noncalibrated ISBs (Apollo subgroup) (n=10). In the Stand subgroup, a standard ISB (Accurate Implant Body MUA) was positioned on each implant abutment, and experimental scans were captured. In the Apollo subgroup, a horizontal ISB (Apollo) was positioned on each implant abutment, connecting the implants horizontally following the arch shape. The standard tessellation language (STL) files of all the experimental scans were exported. A program (DentalCAD) was used to design a complete arch implant-supported bar from the control and each experimental scan. Then, another program (Geomagic) was used to perform linear and angular measurements of the implant interfaces of each bar. The measurements obtained in the control scan were used as a reference to measure the scanning distortion of each specimen. The 2-way ANOVA Welch and pairwise multiple comparison Tukey tests were used to analyze trueness (α=.05). The Levene and pairwise multiple comparison Wilcoxon rank tests were applied to analyze precision (α=.05).</p><p><strong>Results: </strong>Significant linear trueness differences were found between the subgroups (P<.001) with a significant interaction group×subgroup (P<.05). The iTero system demonstrated a significantly worse linear trueness compared with the other IOSs (P<.001). The TRIOS 5 obtained the worst linear precision. Significant angular trueness discrepancies were found between the groups (P<.001) and subgroups (P=.048) with a significant interaction group×subgroup (P=.041). The Apollo group obtained better angular trueness (P<.001) and precision (P<.001) compared with the Stand ISBs group.</p><p><strong>Conclusions: </strong>Both the implant scanning technique and choice of IOS impacted the accuracy of complete arch implant scans.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2025.02.062","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem: Splinting implant scan bodies (ISBs) has been reported to improve the accuracy of intraoral scanners (IOSs) compared with nonsplinting methods. However, the accuracy of commercially available horizontal noncalibrated ISBs remains unknown.

Purpose: The purpose of this in vitro study was to compare the accuracy of complete arch scans obtained using horizontal noncalibrated or standard ISBs recorded by using 5 different IOSs.

Material and methods: An edentulous maxillary stone cast with 6 implant abutment analogs (MultiUnit Abutment Plus Replica) was used. The reference scan was obtained by digitizing the reference cast with a calibrated laboratory scanner (T710). Five groups were created based on the IOS tested: TRIOS 5, i700, Primescan, Aoralscan 3, and iTero. Two subgroups were defined based on the ISBs selected to record complete arch implant scans: standard ISBs (Stand subgroup) or horizontal noncalibrated ISBs (Apollo subgroup) (n=10). In the Stand subgroup, a standard ISB (Accurate Implant Body MUA) was positioned on each implant abutment, and experimental scans were captured. In the Apollo subgroup, a horizontal ISB (Apollo) was positioned on each implant abutment, connecting the implants horizontally following the arch shape. The standard tessellation language (STL) files of all the experimental scans were exported. A program (DentalCAD) was used to design a complete arch implant-supported bar from the control and each experimental scan. Then, another program (Geomagic) was used to perform linear and angular measurements of the implant interfaces of each bar. The measurements obtained in the control scan were used as a reference to measure the scanning distortion of each specimen. The 2-way ANOVA Welch and pairwise multiple comparison Tukey tests were used to analyze trueness (α=.05). The Levene and pairwise multiple comparison Wilcoxon rank tests were applied to analyze precision (α=.05).

Results: Significant linear trueness differences were found between the subgroups (P<.001) with a significant interaction group×subgroup (P<.05). The iTero system demonstrated a significantly worse linear trueness compared with the other IOSs (P<.001). The TRIOS 5 obtained the worst linear precision. Significant angular trueness discrepancies were found between the groups (P<.001) and subgroups (P=.048) with a significant interaction group×subgroup (P=.041). The Apollo group obtained better angular trueness (P<.001) and precision (P<.001) compared with the Stand ISBs group.

Conclusions: Both the implant scanning technique and choice of IOS impacted the accuracy of complete arch implant scans.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信