Effect of stent shape in areas of high compression on patency rates after venous recanalization in patients with chronic venous obstruction.

IF 1.5 4区 医学 Q3 PERIPHERAL VASCULAR DISEASE
Sharif Elshafei, Karina Schleimer, Alexander Gombert, Houman Jalaie, Mohammad E Barbati
{"title":"Effect of stent shape in areas of high compression on patency rates after venous recanalization in patients with chronic venous obstruction.","authors":"Sharif Elshafei, Karina Schleimer, Alexander Gombert, Houman Jalaie, Mohammad E Barbati","doi":"10.23736/S0392-9590.25.05298-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Venous stenting of the obstructed iliofemoral veins has gained significant popularity over recent years due to its efficacy in restoring venous flow and alleviating symptoms associated with chronic venous obstruction (CVO). The success of venous stenting has been demonstrated through high patency rates, even in cases where stents are implanted in areas of high compression. These stents have been observed to adopt an elliptical shape at areas of high compression, deviating from the expected circular morphology that stents are designed to maintain. This phenomenon raises important questions about its potential impact on stent function and long-term patency rates. The objective of this study was to investigate, through a retrospective analysis, the presence and clinical impact of non-circular-shaped venous stents on patency rates.</p><p><strong>Methods: </strong>From December 2015 to December 2020, a cohort of 115 patients (127 limbs) diagnosed with chronic obstruction of the iliofemoral veins underwent venous angioplasty with stent implantation. Throughout follow-up visits, detailed data were collected, including patient demographics, characteristics, stent types, and ultrasound findings, while especially focusing on the shape and diameter of stents at areas of known external compression, such as the May-Thurner point and under the inguinal ligament.</p><p><strong>Results: </strong>The average follow-up duration was 21.9±8.7 months. The primary patency rate was 79.5%, with an assisted primary patency rate of 92.1% and a secondary patency rate of 96.7%. All the stents implanted were dedicated venous stents, which demonstrated favorable outcomes overall. However, during the follow-up period, 76.56% of the stents were found to have adopted an elliptical shape at areas of high external compression, regardless of the type or structure of the stent. Interestingly, neither the change in stent shape nor a reduction in stent area of less than 25% showed any statistically significant impact on the overall patency rates.</p><p><strong>Conclusions: </strong>This study demonstrates that changes in stent shape are to be expected at points of high external pressure. However, as long as these changes do not lead to a severe reduction in stent lumen (<25% of stent area), they do not negatively impact patency rates.</p>","PeriodicalId":13709,"journal":{"name":"International Angiology","volume":"44 1","pages":"6-13"},"PeriodicalIF":1.5000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Angiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S0392-9590.25.05298-8","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Venous stenting of the obstructed iliofemoral veins has gained significant popularity over recent years due to its efficacy in restoring venous flow and alleviating symptoms associated with chronic venous obstruction (CVO). The success of venous stenting has been demonstrated through high patency rates, even in cases where stents are implanted in areas of high compression. These stents have been observed to adopt an elliptical shape at areas of high compression, deviating from the expected circular morphology that stents are designed to maintain. This phenomenon raises important questions about its potential impact on stent function and long-term patency rates. The objective of this study was to investigate, through a retrospective analysis, the presence and clinical impact of non-circular-shaped venous stents on patency rates.

Methods: From December 2015 to December 2020, a cohort of 115 patients (127 limbs) diagnosed with chronic obstruction of the iliofemoral veins underwent venous angioplasty with stent implantation. Throughout follow-up visits, detailed data were collected, including patient demographics, characteristics, stent types, and ultrasound findings, while especially focusing on the shape and diameter of stents at areas of known external compression, such as the May-Thurner point and under the inguinal ligament.

Results: The average follow-up duration was 21.9±8.7 months. The primary patency rate was 79.5%, with an assisted primary patency rate of 92.1% and a secondary patency rate of 96.7%. All the stents implanted were dedicated venous stents, which demonstrated favorable outcomes overall. However, during the follow-up period, 76.56% of the stents were found to have adopted an elliptical shape at areas of high external compression, regardless of the type or structure of the stent. Interestingly, neither the change in stent shape nor a reduction in stent area of less than 25% showed any statistically significant impact on the overall patency rates.

Conclusions: This study demonstrates that changes in stent shape are to be expected at points of high external pressure. However, as long as these changes do not lead to a severe reduction in stent lumen (<25% of stent area), they do not negatively impact patency rates.

高压迫区支架形状对慢性静脉阻塞患者静脉再通后通畅率的影响。
背景:由于其在恢复静脉流动和缓解慢性静脉阻塞(CVO)相关症状方面的疗效,阻塞的髂股静脉支架置入术近年来得到了广泛的应用。静脉支架术的成功已经通过高通畅率证明,即使在高压迫区域植入支架的情况下也是如此。这些支架已被观察到在高压缩区域采用椭圆形状,偏离了预期的支架设计维持的圆形形态。这一现象提出了关于其对支架功能和长期通畅率的潜在影响的重要问题。本研究的目的是通过回顾性分析,探讨非圆形静脉支架的存在及其对通畅率的临床影响。方法:2015年12月至2020年12月,对确诊为慢性髂股静脉梗阻的115例患者(127条肢体)行静脉血管成形术联合支架植入术。在整个随访过程中,收集了详细的数据,包括患者人口统计学、特征、支架类型和超声检查结果,同时特别关注已知外部压迫区域(如May-Thurner点和腹股沟韧带下)支架的形状和直径。结果:平均随访21.9±8.7个月。原发性通畅率为79.5%,辅助原发性通畅率为92.1%,二次通畅率为96.7%。所有植入的支架均为专用静脉支架,总体效果良好。然而,在随访期间,无论支架的类型或结构如何,76.56%的支架在高外压区均采用椭圆形状。有趣的是,支架形状的改变和支架面积的减少都没有显示出对总体通畅率的统计学显著影响。结论:本研究表明,在高外压点,支架形状的改变是可以预期的。然而,只要这些改变不导致支架内腔严重减少(
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Angiology
International Angiology 医学-外周血管病
CiteScore
2.80
自引率
28.60%
发文量
89
审稿时长
6-12 weeks
期刊介绍: International Angiology publishes scientific papers on angiology. Manuscripts may be submitted in the form of editorials, original articles, review articles, special articles, letters to the Editor and guidelines. The journal aims to provide its readers with papers of the highest quality and impact through a process of careful peer review and editorial work. Duties and responsibilities of all the subjects involved in the editorial process are summarized at Publication ethics. Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (ICMJE).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信