Rihwa Choi, Jong Do Seo, Eun-Jung Cho, Woochang Lee, Yeo-Min Yun
{"title":"Adjustment Formula for Harmonizing Triglyceride Values in the Korea National Health and Nutrition Examination Survey, 2005-2022.","authors":"Rihwa Choi, Jong Do Seo, Eun-Jung Cho, Woochang Lee, Yeo-Min Yun","doi":"10.3343/alm.2024.0317","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Korea National Health and Nutrition Examination Survey (KNHANES) triglyceride testing changed from the glycerol blanking method (2005-2021) to the glycerol non-blanking method (2022). We converted triglyceride data from 2005-2021 to that obtained since 2022 with different analytical methods.</p><p><strong>Methods: </strong>To develop a conversion equation, 98 fresh serum specimen pairs were compared using Passing-Bablok regression analysis. Implications of the conversion equation on epidemiological data were evaluated using KNHANES data from 2019-2021. Bias estimations determined using the Lipid Standardization Program (LSP) of the United States Centers for Disease Control and Prevention (CDC) enhanced the accuracy and comparability of the triglyceride results.</p><p><strong>Results: </strong>Triglyceride concentrations measured via the glycerol non-blanking method were 10.7 mg/dL (0.12 mmol/L, 10.0%) higher than those from the glycerol blanking method, with a 9.9 mg/dL (0.11 mmol/L, 5.0%) difference at a concentration of 200 mg/dL (2.26 mmol/L, N=98). The conversion equation y (glycerol non-blanking, 2022)=11.94+0.99x(glycerol blanking, 2005-2021) changed the mean triglyceride concentrations of the KNHANES 2019-2021 data (N=16,015) from 123.7 mg/dL (1.40 mmol/L, 95% confidence interval [CI]: 122.2-125.1 mg/dL [1.38-1.41 mmol/L]) to 134.3 mg/dL (1.52 mmol/L, 95% CI: 132.9-135.8 mg/dL [1.50-1.53 mmol/L]). Since 2022, bias monitoring using the CDC's LSP has remained within a 5.0% limit.</p><p><strong>Conclusions: </strong>KNHANES triglyceride values in 2022 (non-blanking) were substantially higher than those from 2005-2021 (blanking). Conversion equations helped effectively adjust 2005-2021 data. Researchers should consider adjusting the KNHANES triglyceride data based on their study characteristics.</p>","PeriodicalId":8421,"journal":{"name":"Annals of Laboratory Medicine","volume":" ","pages":""},"PeriodicalIF":4.0000,"publicationDate":"2025-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Laboratory Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3343/alm.2024.0317","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Korea National Health and Nutrition Examination Survey (KNHANES) triglyceride testing changed from the glycerol blanking method (2005-2021) to the glycerol non-blanking method (2022). We converted triglyceride data from 2005-2021 to that obtained since 2022 with different analytical methods.
Methods: To develop a conversion equation, 98 fresh serum specimen pairs were compared using Passing-Bablok regression analysis. Implications of the conversion equation on epidemiological data were evaluated using KNHANES data from 2019-2021. Bias estimations determined using the Lipid Standardization Program (LSP) of the United States Centers for Disease Control and Prevention (CDC) enhanced the accuracy and comparability of the triglyceride results.
Results: Triglyceride concentrations measured via the glycerol non-blanking method were 10.7 mg/dL (0.12 mmol/L, 10.0%) higher than those from the glycerol blanking method, with a 9.9 mg/dL (0.11 mmol/L, 5.0%) difference at a concentration of 200 mg/dL (2.26 mmol/L, N=98). The conversion equation y (glycerol non-blanking, 2022)=11.94+0.99x(glycerol blanking, 2005-2021) changed the mean triglyceride concentrations of the KNHANES 2019-2021 data (N=16,015) from 123.7 mg/dL (1.40 mmol/L, 95% confidence interval [CI]: 122.2-125.1 mg/dL [1.38-1.41 mmol/L]) to 134.3 mg/dL (1.52 mmol/L, 95% CI: 132.9-135.8 mg/dL [1.50-1.53 mmol/L]). Since 2022, bias monitoring using the CDC's LSP has remained within a 5.0% limit.
Conclusions: KNHANES triglyceride values in 2022 (non-blanking) were substantially higher than those from 2005-2021 (blanking). Conversion equations helped effectively adjust 2005-2021 data. Researchers should consider adjusting the KNHANES triglyceride data based on their study characteristics.
期刊介绍:
Annals of Laboratory Medicine is the official journal of Korean Society for Laboratory Medicine. The journal title has been recently changed from the Korean Journal of Laboratory Medicine (ISSN, 1598-6535) from the January issue of 2012. The JCR 2017 Impact factor of Ann Lab Med was 1.916.