Sofia I. Nagornaya, Evgeniya V. Polyakova, Ruslan E. Nikolaev and Elena N. Nigmatulina
{"title":"ICP-OES determination of major and trace composition of gadolinium(iii) oxide crystals doped with europium†","authors":"Sofia I. Nagornaya, Evgeniya V. Polyakova, Ruslan E. Nikolaev and Elena N. Nigmatulina","doi":"10.1039/D4JA00452C","DOIUrl":null,"url":null,"abstract":"<p >The ICP-OES method for determination of the main and trace composition of europium-doped gadolinium(<small>III</small>) oxide crystals from a single solution has been developed. Axial plasma viewing was used for trace analysis, and radial viewing was used for the Eu/Gd determination. Different variants of calibration solution preparation were compared: mixing aliquots and joint dissolution of samples. The parameters of spectra registration that minimized the relative standard deviation (RSD) of the emission intensities were selected; the results obtained using the “aliquot mixing” method coincided with the results of an electron microprobe analysis. The RSD in the Eu/Gd molar ratio is 1.5%. It is shown that the maximum ICP power provides minimum detection limits for trace elements at a Gd concentration of 1500 mg L<small><sup>−1</sup></small> in solution, amounting to <em>n</em>·10<small><sup>−6</sup></small> to <em>n</em>·10<small><sup>−3</sup></small>% w/w for 52 elements.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 4","pages":" 954-960"},"PeriodicalIF":3.1000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ja/d4ja00452c","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The ICP-OES method for determination of the main and trace composition of europium-doped gadolinium(III) oxide crystals from a single solution has been developed. Axial plasma viewing was used for trace analysis, and radial viewing was used for the Eu/Gd determination. Different variants of calibration solution preparation were compared: mixing aliquots and joint dissolution of samples. The parameters of spectra registration that minimized the relative standard deviation (RSD) of the emission intensities were selected; the results obtained using the “aliquot mixing” method coincided with the results of an electron microprobe analysis. The RSD in the Eu/Gd molar ratio is 1.5%. It is shown that the maximum ICP power provides minimum detection limits for trace elements at a Gd concentration of 1500 mg L−1 in solution, amounting to n·10−6 to n·10−3% w/w for 52 elements.