High-resolution continuum source quartz tube atomic absorption spectrometry for the determination of As, Sb, Bi, Hg, Se and Te in food and environmental matrices after chemical vapor generation†

IF 3.1 2区 化学 Q2 CHEMISTRY, ANALYTICAL
Bettina Dora Szeredai, Tiberiu Frentiu, Norbert Muntean, Adrian-Ioan Dudu and Eniko Covaci
{"title":"High-resolution continuum source quartz tube atomic absorption spectrometry for the determination of As, Sb, Bi, Hg, Se and Te in food and environmental matrices after chemical vapor generation†","authors":"Bettina Dora Szeredai, Tiberiu Frentiu, Norbert Muntean, Adrian-Ioan Dudu and Eniko Covaci","doi":"10.1039/D4JA00468J","DOIUrl":null,"url":null,"abstract":"<p >This study presents a broadly applicable spectrometric method for the determination of As, Sb, Bi, Hg, Se, and Te in food and environmental matrices based on chemical vapor generation high-resolution continuum source quartz tube atomic absorption spectrometry as a sequential method. The samples were subjected to microwave-assisted digestion, followed by the pre-reduction of As(<small>V</small>) and Sb(<small>V</small>) with 0.05 mol L<small><sup>–1</sup></small> thiourea in a 0.5 mol L<small><sup>–1</sup></small> HCl medium and Se(<small>VI</small>) and Te(<small>VI</small>) in a 7 mol L<small><sup>–1</sup></small> HCl medium. Chemical vapor was generated from an aliquot volume of 5 mL sample in 0.5 mol L<small><sup>–1</sup></small> HCl for As, Sb, Bi and Hg and 7 mol L<small><sup>−1</sup></small> for Se and Te by the addition of 3.5 and 2 mL of 2.5% (m/v) NaBH<small><sub>4</sub></small> solution stabilized in 0.1% (m/v) NaOH for Hg, Se, and Te and As, Bi, and Sb, respectively. Three pretreatment methods, namely, (i) addition of 1% (m/v) sulfamic acid; (ii) N<small><sub>2</sub></small> purging of the solution for 20 min; and (iii) addition of 1% (m/v) sulfamic acid followed by 10 min N<small><sub>2</sub></small> purging, were investigated for the elimination of nitrite and NO<small><sub><em>x</em></sub></small> non-spectral interferences in the Se and Te determination. However, it was observed that pre-washing the reaction cell and the quartz tube atomizer with 6 L min<small><sup>–1</sup></small> argon for 20 s (As, Bi, Se, Te) and 30 s (Sb), after sample introduction into the reaction cell and before NaBH<small><sub>4</sub></small> solution addition, was crucial for the elimination of spectral interferences from residual NO<small><sub><em>x</em></sub></small> and O<small><sub>2</sub></small>, regardless of the sample pretreatment method. An increase in pre-washing time resulted in a decrease in the signal for all elements, indicating that the presence of O<small><sub>2</sub></small> traces is beneficial for high sensitivity. The limits of detection were (mg kg<small><sup>−1</sup></small>) 0.031 (Hg); 0.016 (As); 0.015 (Bi); 0.008 (Sb); 0.084 (Se); and 0.030 (Te). The analysis of certified reference materials indicated recoveries of 98–103% and an expanded uncertainty of ±(17–18)% (<em>k</em> = 2, 95% confidence level). The <em>z</em>′ or <em>z</em> scores indicated a satisfactory performance of the method. The precision, evaluated from extended uncertainty (<em>k</em> = 2, <em>n</em> = 3) by analysis of real samples, was in the range of 4–10.7%.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 4","pages":" 942-953"},"PeriodicalIF":3.1000,"publicationDate":"2025-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2025/ja/d4ja00468j?page=search","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ja/d4ja00468j","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study presents a broadly applicable spectrometric method for the determination of As, Sb, Bi, Hg, Se, and Te in food and environmental matrices based on chemical vapor generation high-resolution continuum source quartz tube atomic absorption spectrometry as a sequential method. The samples were subjected to microwave-assisted digestion, followed by the pre-reduction of As(V) and Sb(V) with 0.05 mol L–1 thiourea in a 0.5 mol L–1 HCl medium and Se(VI) and Te(VI) in a 7 mol L–1 HCl medium. Chemical vapor was generated from an aliquot volume of 5 mL sample in 0.5 mol L–1 HCl for As, Sb, Bi and Hg and 7 mol L−1 for Se and Te by the addition of 3.5 and 2 mL of 2.5% (m/v) NaBH4 solution stabilized in 0.1% (m/v) NaOH for Hg, Se, and Te and As, Bi, and Sb, respectively. Three pretreatment methods, namely, (i) addition of 1% (m/v) sulfamic acid; (ii) N2 purging of the solution for 20 min; and (iii) addition of 1% (m/v) sulfamic acid followed by 10 min N2 purging, were investigated for the elimination of nitrite and NOx non-spectral interferences in the Se and Te determination. However, it was observed that pre-washing the reaction cell and the quartz tube atomizer with 6 L min–1 argon for 20 s (As, Bi, Se, Te) and 30 s (Sb), after sample introduction into the reaction cell and before NaBH4 solution addition, was crucial for the elimination of spectral interferences from residual NOx and O2, regardless of the sample pretreatment method. An increase in pre-washing time resulted in a decrease in the signal for all elements, indicating that the presence of O2 traces is beneficial for high sensitivity. The limits of detection were (mg kg−1) 0.031 (Hg); 0.016 (As); 0.015 (Bi); 0.008 (Sb); 0.084 (Se); and 0.030 (Te). The analysis of certified reference materials indicated recoveries of 98–103% and an expanded uncertainty of ±(17–18)% (k = 2, 95% confidence level). The z′ or z scores indicated a satisfactory performance of the method. The precision, evaluated from extended uncertainty (k = 2, n = 3) by analysis of real samples, was in the range of 4–10.7%.

Abstract Image

利用高分辨率连续光源石英管原子吸收光谱法测定化学蒸汽发生后食品和环境基质中的砷、锑、铋、汞、硒和碲†。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信