A shielded 32-channel body transceiver array with integrated electronics for 7 T.

IF 3 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Tobey D Haluptzok, Russell L Lagore, Simon Schmidt, Gregory J Metzger
{"title":"A shielded 32-channel body transceiver array with integrated electronics for 7 T.","authors":"Tobey D Haluptzok, Russell L Lagore, Simon Schmidt, Gregory J Metzger","doi":"10.1002/mrm.30498","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Develop a 32-channel transceiver array for 7 T body imaging that incorporates an RF shield, improves SNR, lowers g-factors, and is robust to external loading.</p><p><strong>Methods: </strong>The addition of a local RF shield was first investigated for single resonant blocks consisting of either one loop and a dipole (LD) or three loops and a dipole (3LD). A 32-channel array consisting of eight shielded 3LD blocks (32LD-SH) was constructed and validated for in-vivo use. The SNR, parallel imaging, and transmit performance were compared to a previously published 16-channel LD array (16LD). The effect of top loading was investigated by placing arms on top of the coils and measuring S-parameter changes. In vivo imaging of multiple anatomies was performed.</p><p><strong>Results: </strong>In single block experiments, the RF shield impacted SNR and <math> <semantics> <mrow><msubsup><mi>B</mi> <mn>1</mn> <mo>+</mo></msubsup> </mrow> <annotation>$$ {\\mathrm{B}}_1^{+} $$</annotation></semantics> </math> performance by <5%. The 3LD blocks had 80% higher peripheral SNR and 25% higher SNR at a depth of 10 cm. The 32LD-SH array had 18% lower <math> <semantics> <mrow><msubsup><mi>B</mi> <mn>1</mn> <mo>+</mo></msubsup> </mrow> <annotation>$$ {B}_1^{+} $$</annotation></semantics> </math> /W<sup>0.5</sup> efficiency and 30% higher central SNR compared to the 16LD array and supported threefold acceleration in the foot-head direction. Arm placement had no effect on the 32LD-SH array but reduced the 16LD match to 5.4 dB.</p><p><strong>Conclusion: </strong>A 32-channel transceiver array was developed for 7 T body imaging that is insensitive to top loading and has higher SNR and lower g-factors compared to an existing 16-channel transceiver array. Despite lower transmit performance, parallel transmit optimization permitted the 32LD-SH to achieve flip angles necessary for high-quality gradient and spin echo acquisitions of target organs in the chest, abdomen, and pelvis.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.30498","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Develop a 32-channel transceiver array for 7 T body imaging that incorporates an RF shield, improves SNR, lowers g-factors, and is robust to external loading.

Methods: The addition of a local RF shield was first investigated for single resonant blocks consisting of either one loop and a dipole (LD) or three loops and a dipole (3LD). A 32-channel array consisting of eight shielded 3LD blocks (32LD-SH) was constructed and validated for in-vivo use. The SNR, parallel imaging, and transmit performance were compared to a previously published 16-channel LD array (16LD). The effect of top loading was investigated by placing arms on top of the coils and measuring S-parameter changes. In vivo imaging of multiple anatomies was performed.

Results: In single block experiments, the RF shield impacted SNR and B 1 + $$ {\mathrm{B}}_1^{+} $$ performance by <5%. The 3LD blocks had 80% higher peripheral SNR and 25% higher SNR at a depth of 10 cm. The 32LD-SH array had 18% lower B 1 + $$ {B}_1^{+} $$ /W0.5 efficiency and 30% higher central SNR compared to the 16LD array and supported threefold acceleration in the foot-head direction. Arm placement had no effect on the 32LD-SH array but reduced the 16LD match to 5.4 dB.

Conclusion: A 32-channel transceiver array was developed for 7 T body imaging that is insensitive to top loading and has higher SNR and lower g-factors compared to an existing 16-channel transceiver array. Despite lower transmit performance, parallel transmit optimization permitted the 32LD-SH to achieve flip angles necessary for high-quality gradient and spin echo acquisitions of target organs in the chest, abdomen, and pelvis.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信