Natalia V Korobova, Nienke P M Wassenaar, Marian A Troelstra, Eric M Schrauben, Oliver J Gurney-Champion
{"title":"A correction for modeling radial, spiral, and PROPELLER dynamic contrast-enhanced data: Time-averaged extended Tofts.","authors":"Natalia V Korobova, Nienke P M Wassenaar, Marian A Troelstra, Eric M Schrauben, Oliver J Gurney-Champion","doi":"10.1002/mrm.30514","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Dynamic contrast-enhanced sequences (e.g. spiral, radial, PROPELLER MRI) often rely on oversampling the center of k-space. Instead of the discrete snapshots obtained by Cartesian sampling, oversampling the k-space center results in time-averaging of the signal. We hypothesize that these time-averaged signals decrease the accuracy of pharmacokinetic modeling and propose a model that accounts for this effect.</p><p><strong>Theory and methods: </strong>To test our hypothesis, a modified extended Tofts model tailored to accommodate time-averaged signals is proposed. Simulated Monte Carlo experiments were conducted to compare the performance of the modified model with the conventional model. Additionally, to validate the findings in vivo, models were fitted to pseudo-spiral variable-density dynamic contrast-enhanced MRI scans of pancreatic cancer patients reconstructed at 4, 8, 10, and 15 s/frame.</p><p><strong>Results: </strong>The simulations demonstrated that for time-averaged acquisitions, our modified extended Tofts model provided more accurate and precise results than conventional models. Additionally, by integrating signals, some information on high temporal behavior was recovered. Particularly, at long acquisitions (15 s/frame), variable-density sampling with the modified model outperformed conventional discrete sampling. In vivo experiments confirmed these findings, as the corrected model showed more consistent estimates of parameters <math> <semantics> <mrow><msub><mi>v</mi> <mi>p</mi></msub> </mrow> <annotation>$$ {v}_p $$</annotation></semantics> </math> and <math> <semantics> <mrow><msub><mi>v</mi> <mi>e</mi></msub> </mrow> <annotation>$$ {v}_e $$</annotation></semantics> </math> over the tested sampling frequencies, highlighting its potential to improve accuracy in clinical settings.</p><p><strong>Conclusion: </strong>Our study demonstrates that time-averaged signals lead to decreased accuracy and precision in pharmacokinetic modeling when ignored. We suggest using our corrected pharmacokinetic model when performing dynamic contrast-enhanced with variable-density acquisitions, especially for dynamic scan times that are 8 s and longer.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.30514","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Dynamic contrast-enhanced sequences (e.g. spiral, radial, PROPELLER MRI) often rely on oversampling the center of k-space. Instead of the discrete snapshots obtained by Cartesian sampling, oversampling the k-space center results in time-averaging of the signal. We hypothesize that these time-averaged signals decrease the accuracy of pharmacokinetic modeling and propose a model that accounts for this effect.
Theory and methods: To test our hypothesis, a modified extended Tofts model tailored to accommodate time-averaged signals is proposed. Simulated Monte Carlo experiments were conducted to compare the performance of the modified model with the conventional model. Additionally, to validate the findings in vivo, models were fitted to pseudo-spiral variable-density dynamic contrast-enhanced MRI scans of pancreatic cancer patients reconstructed at 4, 8, 10, and 15 s/frame.
Results: The simulations demonstrated that for time-averaged acquisitions, our modified extended Tofts model provided more accurate and precise results than conventional models. Additionally, by integrating signals, some information on high temporal behavior was recovered. Particularly, at long acquisitions (15 s/frame), variable-density sampling with the modified model outperformed conventional discrete sampling. In vivo experiments confirmed these findings, as the corrected model showed more consistent estimates of parameters and over the tested sampling frequencies, highlighting its potential to improve accuracy in clinical settings.
Conclusion: Our study demonstrates that time-averaged signals lead to decreased accuracy and precision in pharmacokinetic modeling when ignored. We suggest using our corrected pharmacokinetic model when performing dynamic contrast-enhanced with variable-density acquisitions, especially for dynamic scan times that are 8 s and longer.
期刊介绍:
Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.