Concordance of vibration-controlled transient elastography and magnetic resonance elastography for fibrosis staging in patients with metabolic dysfunction-associated steatotic liver disease.

IF 4.7 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Anandita Mathur, Efe Ozkaya, Sonam Rosberger, Keith M Sigel, John T Doucette, Meena B Bansal, Bachir Taouli
{"title":"Concordance of vibration-controlled transient elastography and magnetic resonance elastography for fibrosis staging in patients with metabolic dysfunction-associated steatotic liver disease.","authors":"Anandita Mathur, Efe Ozkaya, Sonam Rosberger, Keith M Sigel, John T Doucette, Meena B Bansal, Bachir Taouli","doi":"10.1007/s00330-025-11533-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the concordance between vibration-controlled transient elastography (VCTE) and magnetic resonance elastography (MRE) for staging liver fibrosis and assessing hypothetical eligibility for resmetirom treatment in a cohort of patients with metabolic dysfunction-associated steatotic liver disease (MASLD). A secondary objective was to assess the performance of VCTE for liver fat quantification.</p><p><strong>Materials and methods: </strong>This retrospective study included 103 patients (61 males; mean age 54.7 years) with suspected MASLD who underwent VCTE and MRI/MRE. The following parameters were extracted: liver stiffness (LS) from both techniques, controlled attenuation parameter (CAP) from VCTE, and MRI-proton density fat fraction (PDFF). Agreement and fibrosis stage distributions were assessed using Cohen's Kappa and McNemar's tests. ROC analysis assessed the performance of CAP against MRI-PDFF (considered the reference for steatosis).</p><p><strong>Results: </strong>A significant difference was observed in assigned fibrosis stage distributions between VCTE and MRE across all combinations (F0-F1 vs F2-F4, F0-F2 vs F3-F4, F0-F3 vs F4, all p < 0.001) with fair to moderate agreement between modalities (Cohen's Kappa values 0.305-0.554). VCTE assigned a higher fibrosis stage in 42 patients (40.7%). Thirty-three vs eighteen patients were classified as F2-F3 (qualified for resmetirom treatment) with VCTE vs MRE (Cohen's Kappa 0.215), which was associated with estimated cost savings of $707,701/year with MRE. VCTE-CAP achieved AUCs of 0.547, 0.754, and 0.813 for diagnosing mild, moderate, and severe steatosis, respectively.</p><p><strong>Conclusion: </strong>VCTE and MRE have fair to moderate agreement for fibrosis staging, with VCTE tending to assign a higher fibrosis stage compared to MRE. VCTE-CAP reliably detects only severe steatosis.</p><p><strong>Key points: </strong>Question What is the agreement between VCTE and MRE in staging fibrosis in MASLD and identifying patients with F2-F3 disease? Findings Limited concordance was found between VCTE and MRE for staging liver fibrosis and identifying F2-F3 disease; VCTE tended to assign higher fibrosis stages compared to MRE. Clinical relevance MRE could represent the modality of choice for selecting patients with metabolic dysfunction-associated steatohepatitis for resmetirom therapy as it potentially offers high cost-savings compared to VCTE.</p>","PeriodicalId":12076,"journal":{"name":"European Radiology","volume":" ","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2025-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00330-025-11533-0","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate the concordance between vibration-controlled transient elastography (VCTE) and magnetic resonance elastography (MRE) for staging liver fibrosis and assessing hypothetical eligibility for resmetirom treatment in a cohort of patients with metabolic dysfunction-associated steatotic liver disease (MASLD). A secondary objective was to assess the performance of VCTE for liver fat quantification.

Materials and methods: This retrospective study included 103 patients (61 males; mean age 54.7 years) with suspected MASLD who underwent VCTE and MRI/MRE. The following parameters were extracted: liver stiffness (LS) from both techniques, controlled attenuation parameter (CAP) from VCTE, and MRI-proton density fat fraction (PDFF). Agreement and fibrosis stage distributions were assessed using Cohen's Kappa and McNemar's tests. ROC analysis assessed the performance of CAP against MRI-PDFF (considered the reference for steatosis).

Results: A significant difference was observed in assigned fibrosis stage distributions between VCTE and MRE across all combinations (F0-F1 vs F2-F4, F0-F2 vs F3-F4, F0-F3 vs F4, all p < 0.001) with fair to moderate agreement between modalities (Cohen's Kappa values 0.305-0.554). VCTE assigned a higher fibrosis stage in 42 patients (40.7%). Thirty-three vs eighteen patients were classified as F2-F3 (qualified for resmetirom treatment) with VCTE vs MRE (Cohen's Kappa 0.215), which was associated with estimated cost savings of $707,701/year with MRE. VCTE-CAP achieved AUCs of 0.547, 0.754, and 0.813 for diagnosing mild, moderate, and severe steatosis, respectively.

Conclusion: VCTE and MRE have fair to moderate agreement for fibrosis staging, with VCTE tending to assign a higher fibrosis stage compared to MRE. VCTE-CAP reliably detects only severe steatosis.

Key points: Question What is the agreement between VCTE and MRE in staging fibrosis in MASLD and identifying patients with F2-F3 disease? Findings Limited concordance was found between VCTE and MRE for staging liver fibrosis and identifying F2-F3 disease; VCTE tended to assign higher fibrosis stages compared to MRE. Clinical relevance MRE could represent the modality of choice for selecting patients with metabolic dysfunction-associated steatohepatitis for resmetirom therapy as it potentially offers high cost-savings compared to VCTE.

振动控制瞬时弹性成像和磁共振弹性成像对代谢功能障碍相关脂肪变性肝病患者纤维化分期的一致性
目的:评估振动控制瞬时弹性成像(VCTE)和磁共振弹性成像(MRE)对肝纤维化分期的一致性,并评估代谢功能障碍相关脂肪变性肝病(MASLD)患者雷司替康治疗的假设资格。第二个目的是评估VCTE用于肝脏脂肪定量的性能。材料与方法:本研究纳入103例患者(男61例;平均年龄54.7岁),疑似MASLD,行VCTE和MRI/MRE检查。提取以下参数:两种技术的肝脏硬度(LS)、VCTE的控制衰减参数(CAP)和mri质子密度脂肪分数(PDFF)。采用Cohen's Kappa和McNemar试验评估一致性和纤维化分期分布。ROC分析评估CAP对抗MRI-PDFF的表现(被认为是脂肪变性的参考)。结果:在所有组合中,VCTE和MRE之间分配的纤维化分期分布有显著差异(F0-F1 vs F2-F4, F0-F2 vs F3-F4, F0-F3 vs F4)。结论:VCTE和MRE对纤维化分期具有公平至中度的一致性,与MRE相比,VCTE倾向于分配更高的纤维化分期。VCTE-CAP仅可靠地检测严重的脂肪变性。VCTE和MRE在MASLD纤维化分期和F2-F3疾病鉴别方面有何一致之处?VCTE与MRE在肝纤维化分期和F2-F3疾病鉴别方面的一致性有限;与MRE相比,VCTE倾向于分配更高的纤维化分期。与VCTE相比,MRE可能代表了选择代谢功能障碍相关脂肪性肝炎患者进行雷司替罗治疗的选择模式,因为它可能提供更高的成本节约。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
European Radiology
European Radiology 医学-核医学
CiteScore
11.60
自引率
8.50%
发文量
874
审稿时长
2-4 weeks
期刊介绍: European Radiology (ER) continuously updates scientific knowledge in radiology by publication of strong original articles and state-of-the-art reviews written by leading radiologists. A well balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes ER an indispensable source for current information in this field. This is the Journal of the European Society of Radiology, and the official journal of a number of societies. From 2004-2008 supplements to European Radiology were published under its companion, European Radiology Supplements, ISSN 1613-3749.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信