{"title":"Rapid Determination of 15 Herbicides in Blood and Soil by Direct Analysis in Real Time-Tandem Mass Spectrometry","authors":"Zhou Yuan, Zhang Ying, Hou Xiaolong, Xue Chenyu, Zhang Wenfang, Qiao Jing, Liu Hua, Zhang Wenjin, Guo Yizhu","doi":"10.1002/rcm.10023","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Rationale</h3>\n \n <p>The rampant abuse of herbicides in agricultural practices has resulted in frequent incidents of both unintended and deliberate poisoning, posing dual threats to ecosystems and human health. This underscores an urgent need for efficient herbicide detection methods.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>A direct analysis in real time coupled with tandem mass spectrometry (DART-MS/MS) method was developed for the simultaneous detection of 15 herbicides in blood and soil. Systematic optimization of mass spectrometric parameters established optimal detection conditions in multiple reaction monitoring (MRM) mode, with the ion source temperature set at 450°C. Following liquid-liquid extraction of blood or soil samples, the processed supernatant was analyzed directly.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The method demonstrated excellent linearity (R<sup>²</sup> ≥ 0.99) across a wide concentration range. Sensitivity was validated with limits of detection (LODs) of 1–20 ng/mL in blood and 1–10 ng/g in soil, and limits of quantification (LOQs) of 1–50 ng/mL in blood and 1–20 ng/g in soil. Satisfactory recovery rates and controlled matrix effects met toxicological requirements. In 2024, the method was successfully applied to four real cases of herbicide poisoning.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>This study established the first DART-MS/MS method for simultaneous analysis of 15 herbicides in biological (blood) and environmental (soil) matrices. The complete analytical workflow required only 20 minutes from sample preparation to detection, significantly advancing forensic applications of DART-MS/MSwhile providing a reliable technical solution for herbicide screening in forensic investigations.</p>\n </section>\n </div>","PeriodicalId":225,"journal":{"name":"Rapid Communications in Mass Spectrometry","volume":"39 12","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rapid Communications in Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcm.10023","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Rationale
The rampant abuse of herbicides in agricultural practices has resulted in frequent incidents of both unintended and deliberate poisoning, posing dual threats to ecosystems and human health. This underscores an urgent need for efficient herbicide detection methods.
Methods
A direct analysis in real time coupled with tandem mass spectrometry (DART-MS/MS) method was developed for the simultaneous detection of 15 herbicides in blood and soil. Systematic optimization of mass spectrometric parameters established optimal detection conditions in multiple reaction monitoring (MRM) mode, with the ion source temperature set at 450°C. Following liquid-liquid extraction of blood or soil samples, the processed supernatant was analyzed directly.
Results
The method demonstrated excellent linearity (R² ≥ 0.99) across a wide concentration range. Sensitivity was validated with limits of detection (LODs) of 1–20 ng/mL in blood and 1–10 ng/g in soil, and limits of quantification (LOQs) of 1–50 ng/mL in blood and 1–20 ng/g in soil. Satisfactory recovery rates and controlled matrix effects met toxicological requirements. In 2024, the method was successfully applied to four real cases of herbicide poisoning.
Conclusions
This study established the first DART-MS/MS method for simultaneous analysis of 15 herbicides in biological (blood) and environmental (soil) matrices. The complete analytical workflow required only 20 minutes from sample preparation to detection, significantly advancing forensic applications of DART-MS/MSwhile providing a reliable technical solution for herbicide screening in forensic investigations.
期刊介绍:
Rapid Communications in Mass Spectrometry is a journal whose aim is the rapid publication of original research results and ideas on all aspects of the science of gas-phase ions; it covers all the associated scientific disciplines. There is no formal limit on paper length ("rapid" is not synonymous with "brief"), but papers should be of a length that is commensurate with the importance and complexity of the results being reported. Contributions may be theoretical or practical in nature; they may deal with methods, techniques and applications, or with the interpretation of results; they may cover any area in science that depends directly on measurements made upon gaseous ions or that is associated with such measurements.