Left atrial appendage occlusion devices: one size doesn't fit all? The turning point of a custom-made device

Q4 Medicine
Silvia Maiani MD , Giulia Nardi MD , Miroslava Stolcova MD , Francesca Ristalli MD , Maria Federica Crociani MD , Niccolò Ciardetti MD , Alessio Mattesini MD , Carlo Di Mario MD, PhD , Francesco Meucci MD
{"title":"Left atrial appendage occlusion devices: one size doesn't fit all? The turning point of a custom-made device","authors":"Silvia Maiani MD ,&nbsp;Giulia Nardi MD ,&nbsp;Miroslava Stolcova MD ,&nbsp;Francesca Ristalli MD ,&nbsp;Maria Federica Crociani MD ,&nbsp;Niccolò Ciardetti MD ,&nbsp;Alessio Mattesini MD ,&nbsp;Carlo Di Mario MD, PhD ,&nbsp;Francesco Meucci MD","doi":"10.1016/j.jccase.2024.12.001","DOIUrl":null,"url":null,"abstract":"<div><div>Left atrial appendage occlusion (LAAO) has as a comparable efficacy and safety profile compared with oral anticoagulation therapy in patients with atrial fibrillation. The procedural success rate is high, but some challenging anatomies may preclude optimal closure with standard devices. Our patient underwent a first LAAO attempt with Amplatzer Amulet 34 mm (St. Jude Medical, Saint Paul, MN, USA) and Watchman FLX 35 mm (Boston Scientific, Marlborough, MA, USA), but device anchoring was not feasible or sub-optimal due to the oversized LAA. The procedure was postponed in order to perform a cardiac computed tomography angiography and a custom-made LAmbre Closure System 42/52 mm (Lifetech Scientific, Shenzhen, China), specifically fitted with patient's LAA anatomy, was successfully implanted. The procedure was straightforward, and the device perfectly adapted to our patient's anatomy, with no residual leak.</div></div><div><h3>Learning objective</h3><div>Left atrial appendage presents several morphologies and procedural success rate of left atrial appendage occlusion is high, but challenging anatomies may preclude optimal closure with standard devices. Our case emphasizes the importance of pre-procedural planning and the safety and feasibility of custom-made devices, overcoming procedural failure of a previous attempt with standard devices.</div></div>","PeriodicalId":52092,"journal":{"name":"Journal of Cardiology Cases","volume":"31 4","pages":"Pages 97-100"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiology Cases","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1878540924001099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Left atrial appendage occlusion (LAAO) has as a comparable efficacy and safety profile compared with oral anticoagulation therapy in patients with atrial fibrillation. The procedural success rate is high, but some challenging anatomies may preclude optimal closure with standard devices. Our patient underwent a first LAAO attempt with Amplatzer Amulet 34 mm (St. Jude Medical, Saint Paul, MN, USA) and Watchman FLX 35 mm (Boston Scientific, Marlborough, MA, USA), but device anchoring was not feasible or sub-optimal due to the oversized LAA. The procedure was postponed in order to perform a cardiac computed tomography angiography and a custom-made LAmbre Closure System 42/52 mm (Lifetech Scientific, Shenzhen, China), specifically fitted with patient's LAA anatomy, was successfully implanted. The procedure was straightforward, and the device perfectly adapted to our patient's anatomy, with no residual leak.

Learning objective

Left atrial appendage presents several morphologies and procedural success rate of left atrial appendage occlusion is high, but challenging anatomies may preclude optimal closure with standard devices. Our case emphasizes the importance of pre-procedural planning and the safety and feasibility of custom-made devices, overcoming procedural failure of a previous attempt with standard devices.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Cardiology Cases
Journal of Cardiology Cases Medicine-Cardiology and Cardiovascular Medicine
CiteScore
0.90
自引率
0.00%
发文量
177
审稿时长
59 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信