Splenic Doppler Resistance Index for Detection of Circulatory Shock in Dogs.

Pablo Alejandro Donati, Pablo E Otero, Lisa Tarragona, Marcela Tunesi, Manuel Martín Flores, Santiago D Alotto, Arnaldo Dubín
{"title":"Splenic Doppler Resistance Index for Detection of Circulatory Shock in Dogs.","authors":"Pablo Alejandro Donati, Pablo E Otero, Lisa Tarragona, Marcela Tunesi, Manuel Martín Flores, Santiago D Alotto, Arnaldo Dubín","doi":"10.1111/vec.13455","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To assess the splenic flow resistance index (RI) and its response to a fluid bolus in dogs showing circulatory abnormalities upon hospital admission.</p><p><strong>Design: </strong>Prospective clinical study.</p><p><strong>Setting: </strong>Veterinary referral hospital.</p><p><strong>Animals: </strong>Nine dogs with circulatory shock and nine dogs without circulatory abnormalities.</p><p><strong>Interventions: </strong>Dogs with circulatory abnormalities received an IV bolus of 30 mL/kg of balanced isotonic crystalloid fluid.</p><p><strong>Measurements and main results: </strong>The splenic flow RI and the baseline aortic velocity-time integral of both groups of dogs were evaluated upon hospital admission. Measurements were repeated after the fluid bolus in dogs with circulatory shock. The Mann-Whitney U-test or the Wilcoxon rank sign test was used as appropriate. The median RI in dogs with circulatory shock was higher than that in dogs without hemodynamic disorders (median [interquartile range]: 0.64 [0.62-0.77] vs. 0.54 [0.51-0.54], P < 0.001). The best cutoff value to discriminate between the two groups was 0.61, with an area under the receiver operating characteristic curve of 1.00 (95% confidence interval [CI]: 1.00-1.00), a sensitivity of 100% (95% CI: 66.4-100), a specificity of 100% (95% CI: 66.4-100), a positive predictive value of 100% (95% CI: 66.4-100), and a negative predictive value of 100% (95% CI: 66.4-100). After fluid expansion, a significant decrease in the median splenic flow RI was observed (0.57 [0.54-0.71], P = 0.007 vs. basal).</p><p><strong>Conclusions: </strong>The splenic flow RI may be a dependable tool for identifying circulatory shock in dogs and assessing their response to fluid therapy. Additional studies are required to evaluate the use of this index for the monitoring of organ perfusion, changes in cardiac output, and fluid responsiveness in critically ill dogs.</p>","PeriodicalId":74015,"journal":{"name":"Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)","volume":" ","pages":"e13455"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/vec.13455","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To assess the splenic flow resistance index (RI) and its response to a fluid bolus in dogs showing circulatory abnormalities upon hospital admission.

Design: Prospective clinical study.

Setting: Veterinary referral hospital.

Animals: Nine dogs with circulatory shock and nine dogs without circulatory abnormalities.

Interventions: Dogs with circulatory abnormalities received an IV bolus of 30 mL/kg of balanced isotonic crystalloid fluid.

Measurements and main results: The splenic flow RI and the baseline aortic velocity-time integral of both groups of dogs were evaluated upon hospital admission. Measurements were repeated after the fluid bolus in dogs with circulatory shock. The Mann-Whitney U-test or the Wilcoxon rank sign test was used as appropriate. The median RI in dogs with circulatory shock was higher than that in dogs without hemodynamic disorders (median [interquartile range]: 0.64 [0.62-0.77] vs. 0.54 [0.51-0.54], P < 0.001). The best cutoff value to discriminate between the two groups was 0.61, with an area under the receiver operating characteristic curve of 1.00 (95% confidence interval [CI]: 1.00-1.00), a sensitivity of 100% (95% CI: 66.4-100), a specificity of 100% (95% CI: 66.4-100), a positive predictive value of 100% (95% CI: 66.4-100), and a negative predictive value of 100% (95% CI: 66.4-100). After fluid expansion, a significant decrease in the median splenic flow RI was observed (0.57 [0.54-0.71], P = 0.007 vs. basal).

Conclusions: The splenic flow RI may be a dependable tool for identifying circulatory shock in dogs and assessing their response to fluid therapy. Additional studies are required to evaluate the use of this index for the monitoring of organ perfusion, changes in cardiac output, and fluid responsiveness in critically ill dogs.

用于检测犬体循环休克的脾脏多普勒阻力指数
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信