{"title":"Hemodynamic Changes After Wire Frame Occluders vs. Metal Mesh Devices for Atrial Septal Defect.","authors":"Mitsutaka Nakashima, Yoichi Takaya, Kentaro Ejiri, Takashi Miki, Rie Nakayama, Koji Nakagawa, Teiji Akagi, Kazufumi Nakamura, Shinsuke Yuasa","doi":"10.1253/circj.CJ-24-0966","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Transcatheter atrial septal defect (ASD) closure is the first treatment option for secundum ASD, but parameters for optimal device selection have not been established. We compared outcomes between occluders with a wire frame and metal mesh devices.</p><p><strong>Methods and results: </strong>This study included secundum ASD patients implanted with a wire frame occluder (GORE<sup>®</sup>CARDIOFORM ASD occluder [GCA]; W.L. Gore & Associates) or metal mesh devices (Amplatzer septal occluder device [Abbott] and Occlutech Figulla Flex II device [Occlutech]). The presence of residual shunt and B-type natriuretic peptide (BNP) levels after implantation were compared. Of the 970 patients with either GCA (n=48) or a metal mesh device (n=922; control), 42 patients from each group were analyzed after propensity score matching. The prevalence of residual shunt was significantly lower in the GCA group 1 day and 1 month after implantation (P<0.001 and P=0.017, respectively), whereas there was no significant difference between the 2 groups 6 months later (P=0.088). BNP levels at 1 month were significantly higher in the GCA group (ratio of change 1.36; 95% confidence interval [CI] 1.01-1.83), but did not differ significantly between the 2 groups at 6 months (ratio of change 1.04; 95% CI 0.65-1.65).</p><p><strong>Conclusions: </strong>Patients implanted with a wire frame occluder had a lower prevalence of residual shunt and a greater increase in BNP levels in the early period after implantation.</p>","PeriodicalId":50691,"journal":{"name":"Circulation Journal","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2025-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1253/circj.CJ-24-0966","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Transcatheter atrial septal defect (ASD) closure is the first treatment option for secundum ASD, but parameters for optimal device selection have not been established. We compared outcomes between occluders with a wire frame and metal mesh devices.

Methods and results: This study included secundum ASD patients implanted with a wire frame occluder (GORE®CARDIOFORM ASD occluder [GCA]; W.L. Gore & Associates) or metal mesh devices (Amplatzer septal occluder device [Abbott] and Occlutech Figulla Flex II device [Occlutech]). The presence of residual shunt and B-type natriuretic peptide (BNP) levels after implantation were compared. Of the 970 patients with either GCA (n=48) or a metal mesh device (n=922; control), 42 patients from each group were analyzed after propensity score matching. The prevalence of residual shunt was significantly lower in the GCA group 1 day and 1 month after implantation (P<0.001 and P=0.017, respectively), whereas there was no significant difference between the 2 groups 6 months later (P=0.088). BNP levels at 1 month were significantly higher in the GCA group (ratio of change 1.36; 95% confidence interval [CI] 1.01-1.83), but did not differ significantly between the 2 groups at 6 months (ratio of change 1.04; 95% CI 0.65-1.65).

Conclusions: Patients implanted with a wire frame occluder had a lower prevalence of residual shunt and a greater increase in BNP levels in the early period after implantation.

房间隔缺损金属网闭塞器与金属网闭塞器后血流动力学的变化。
背景:经导管房间隔缺损(ASD)封堵术是治疗继发性 ASD 的首选方法,但最佳设备选择参数尚未确定。我们比较了使用金属丝框和金属网装置的封堵器的疗效:本研究纳入了植入线框封堵器(GORE®CARDIOFORM ASD 封堵器 [GCA];W.L. Gore & Associates)或金属网装置(Amplatzer 室间隔封堵器 [Abbott] 和 Occlutech Figulla Flex II 装置 [Occlutech])的残留 ASD 患者。对植入后是否存在残余分流和 B 型钠尿肽 (BNP) 水平进行了比较。在 970 名使用 GCA(48 人)或金属网装置(922 人;对照组)的患者中,对每组的 42 名患者进行了倾向评分匹配分析。植入后 1 天和 1 个月,GCA 组残余分流的发生率明显较低(PConclusions:植入线框闭塞器的患者残余分流率较低,植入后早期的 BNP 水平上升幅度较大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Circulation Journal
Circulation Journal 医学-心血管系统
CiteScore
5.80
自引率
12.10%
发文量
471
审稿时长
1.6 months
期刊介绍: Circulation publishes original research manuscripts, review articles, and other content related to cardiovascular health and disease, including observational studies, clinical trials, epidemiology, health services and outcomes studies, and advances in basic and translational research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信