Low-Field Magnetic Resonance Imaging: A Full-Wave Simulation of Radiofrequency Birdcage Coils for Musculoskeletal Limb Imaging.

IF 3 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Giulio Giovannetti, Francesca Frijia, Maria Filomena Santarelli, Vincenzo Positano
{"title":"Low-Field Magnetic Resonance Imaging: A Full-Wave Simulation of Radiofrequency Birdcage Coils for Musculoskeletal Limb Imaging.","authors":"Giulio Giovannetti, Francesca Frijia, Maria Filomena Santarelli, Vincenzo Positano","doi":"10.3390/diagnostics15060713","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Low-field Magnetic Resonance Imaging (MRI) (fields below 0.5 T) has received increasing attention since the images produced have been shown to be diagnostically equivalent to high-field MR images for specific applications, such as musculoskeletal studies. In recent years, low-field MRI has made great strides in clinical relevance due to advances in high-performance gradients, magnet technology, and the development of organ-specific radiofrequency (RF) coils, as well as advances in acquisition sequence design. For achieving optimized image homogeneity and signal-to-noise Ratio (SNR), the design and simulation of dedicated RF coils is a constraint both in clinical and in many research studies. <b>Methods:</b> This paper describes the application of a numerical full-wave method based on the finite-difference time-domain (FDTD) algorithm for the simulation and the design of birdcage coils for musculoskeletal low-field MRI. In particular, the magnetic field pattern in loaded and unloaded conditions was investigated. Moreover, the magnetic field homogeneity variations and the coil detuning after an RF shield insertion were evaluated. Finally, the coil inductance and the sample-induced resistance were estimated. <b>Results:</b> The accuracy of the results was verified by data acquired from two lowpass birdcage prototypes designed for musculoskeletal experiments on a 0.18 T open MR clinical scanner. <b>Conclusions:</b> This work describes the capability of numerical simulations to design RF coils for various scenarios, including the presence of electromagnetic shields and different load conditions.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"15 6","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11941173/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics15060713","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Low-field Magnetic Resonance Imaging (MRI) (fields below 0.5 T) has received increasing attention since the images produced have been shown to be diagnostically equivalent to high-field MR images for specific applications, such as musculoskeletal studies. In recent years, low-field MRI has made great strides in clinical relevance due to advances in high-performance gradients, magnet technology, and the development of organ-specific radiofrequency (RF) coils, as well as advances in acquisition sequence design. For achieving optimized image homogeneity and signal-to-noise Ratio (SNR), the design and simulation of dedicated RF coils is a constraint both in clinical and in many research studies. Methods: This paper describes the application of a numerical full-wave method based on the finite-difference time-domain (FDTD) algorithm for the simulation and the design of birdcage coils for musculoskeletal low-field MRI. In particular, the magnetic field pattern in loaded and unloaded conditions was investigated. Moreover, the magnetic field homogeneity variations and the coil detuning after an RF shield insertion were evaluated. Finally, the coil inductance and the sample-induced resistance were estimated. Results: The accuracy of the results was verified by data acquired from two lowpass birdcage prototypes designed for musculoskeletal experiments on a 0.18 T open MR clinical scanner. Conclusions: This work describes the capability of numerical simulations to design RF coils for various scenarios, including the presence of electromagnetic shields and different load conditions.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Diagnostics
Diagnostics Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍: Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信