{"title":"Vortex Dynamics in the Sinus of Valsalva.","authors":"Jiaxuan Fan, Elias Sundström","doi":"10.3390/bioengineering12030279","DOIUrl":null,"url":null,"abstract":"<p><p>Patients undergoing aortic valve repair or replacement with associated alterations in stiffness characteristics often develop abnormalities in the aortic sinus vortex, which may impact aortic valve function. The correlation between altered aortic sinus vortex and aortic valve function remains poorly understood due to the complex fluid dynamics in the aortic valve and the challenges in simulating these conditions. The opening and closure mechanism of the aortic valve is studied using fluid-structure interaction (FSI) simulations, incorporating an idealized aortic valve model. The FSI approach models both the interaction between the fluid flow and the valve's leaflets and the dynamic response of the leaflets during pulsatile flow conditions. Differences in the hemodynamic and vortex dynamic behaviors of aortic valve leaflets with varying stiffness are analyzed. The results reveal that, during the systolic phase, the formation of the sinus vortex is closely coupled with the jet emanating from the aortic valve and the fluttering motion of the leaflets. As leaflet stiffness increases, the peak vorticity of the sinus vortex increases, and the phase space of the vortex core develops a pronounced spiral trajectory. During the diffusion phase, the vortex strength decays exponentially, and the diffusion time is longer for stiffer leaflets, indicating a longer residence time of the sinus vortex that reduces the pressure difference on the leaflet during valve closure. Changes in leaflet stiffness play a critical role in the formation and development of sinus vortices. Furthermore, the dynamic characteristics of vortices directly affect the pressure balance on both sides of the valve leaflets. This pressure difference not only determines the opening and closing processes of the valve but also significantly influences the stability and efficiency of these actions.</p>","PeriodicalId":8874,"journal":{"name":"Bioengineering","volume":"12 3","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11939515/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering12030279","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Patients undergoing aortic valve repair or replacement with associated alterations in stiffness characteristics often develop abnormalities in the aortic sinus vortex, which may impact aortic valve function. The correlation between altered aortic sinus vortex and aortic valve function remains poorly understood due to the complex fluid dynamics in the aortic valve and the challenges in simulating these conditions. The opening and closure mechanism of the aortic valve is studied using fluid-structure interaction (FSI) simulations, incorporating an idealized aortic valve model. The FSI approach models both the interaction between the fluid flow and the valve's leaflets and the dynamic response of the leaflets during pulsatile flow conditions. Differences in the hemodynamic and vortex dynamic behaviors of aortic valve leaflets with varying stiffness are analyzed. The results reveal that, during the systolic phase, the formation of the sinus vortex is closely coupled with the jet emanating from the aortic valve and the fluttering motion of the leaflets. As leaflet stiffness increases, the peak vorticity of the sinus vortex increases, and the phase space of the vortex core develops a pronounced spiral trajectory. During the diffusion phase, the vortex strength decays exponentially, and the diffusion time is longer for stiffer leaflets, indicating a longer residence time of the sinus vortex that reduces the pressure difference on the leaflet during valve closure. Changes in leaflet stiffness play a critical role in the formation and development of sinus vortices. Furthermore, the dynamic characteristics of vortices directly affect the pressure balance on both sides of the valve leaflets. This pressure difference not only determines the opening and closing processes of the valve but also significantly influences the stability and efficiency of these actions.
期刊介绍:
Aims
Bioengineering (ISSN 2306-5354) provides an advanced forum for the science and technology of bioengineering. It publishes original research papers, comprehensive reviews, communications and case reports. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. All aspects of bioengineering are welcomed from theoretical concepts to education and applications. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, four key features of this Journal:
● We are introducing a new concept in scientific and technical publications “The Translational Case Report in Bioengineering”. It is a descriptive explanatory analysis of a transformative or translational event. Understanding that the goal of bioengineering scholarship is to advance towards a transformative or clinical solution to an identified transformative/clinical need, the translational case report is used to explore causation in order to find underlying principles that may guide other similar transformative/translational undertakings.
● Manuscripts regarding research proposals and research ideas will be particularly welcomed.
● Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material.
● We also accept manuscripts communicating to a broader audience with regard to research projects financed with public funds.
Scope
● Bionics and biological cybernetics: implantology; bio–abio interfaces
● Bioelectronics: wearable electronics; implantable electronics; “more than Moore” electronics; bioelectronics devices
● Bioprocess and biosystems engineering and applications: bioprocess design; biocatalysis; bioseparation and bioreactors; bioinformatics; bioenergy; etc.
● Biomolecular, cellular and tissue engineering and applications: tissue engineering; chromosome engineering; embryo engineering; cellular, molecular and synthetic biology; metabolic engineering; bio-nanotechnology; micro/nano technologies; genetic engineering; transgenic technology
● Biomedical engineering and applications: biomechatronics; biomedical electronics; biomechanics; biomaterials; biomimetics; biomedical diagnostics; biomedical therapy; biomedical devices; sensors and circuits; biomedical imaging and medical information systems; implants and regenerative medicine; neurotechnology; clinical engineering; rehabilitation engineering
● Biochemical engineering and applications: metabolic pathway engineering; modeling and simulation
● Translational bioengineering