Effects on Force, Velocity, Power, and Muscle Activation of Resistances with Variable Inertia Generated by Programmable Electromechanical Motors During Explosive Chest Press Exercises.

IF 3.8 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Luca Zoffoli, Silvano Zanuso, Andrea Biscarini
{"title":"Effects on Force, Velocity, Power, and Muscle Activation of Resistances with Variable Inertia Generated by Programmable Electromechanical Motors During Explosive Chest Press Exercises.","authors":"Luca Zoffoli, Silvano Zanuso, Andrea Biscarini","doi":"10.3390/bioengineering12030292","DOIUrl":null,"url":null,"abstract":"<p><p>Strength training machines incorporating advanced electro-mechanical technologies can produce hybrid resistances with variable inertia, such as a resistance that progressively changes from gravitational (inertial) to pneumatic (non-inertial) across the range of motion (ROM). To explore the biomechanical effects of these innovative resistances, a robotic chest press machine was programmed to offer three distinct inertial profiles: gravitational-type constant inertia throughout the ROM (I<sub>FULL</sub>); no inertia (I<sub>ZERO</sub>); and linearly descending inertia across the ROM (I<sub>VAR</sub>). Ten healthy adults performed five maximal-effort, explosive chest press movements under each inertial profile at 30, 50 and 70% of their one-repetition maximum. During each trial, muscle activity of the pectoralis major, anterior deltoid, and triceps brachii was recorded, along with force, velocity and power outputs from the machine. Statistical non-parametric maps based on two-way repeated measures ANOVA were used to assess the effects of load level and inertial profile on the collected time series. Higher load levels consistently led to increased force and reduced velocity and power outcomes over large parts of the ROM. Compared to I<sub>FULL</sub>, I<sub>ZERO</sub> allowed for greater velocity at the expense of lower force throughout the ROM, while I<sub>VAR</sub> produced higher force and power outputs despite having lower velocity than I<sub>ZERO</sub>. Additionally, both I<sub>ZERO</sub> and I<sub>VAR</sub> significantly increased triceps brachii activity at the end of the ROM compared to I<sub>FULL</sub>. I<sub>VAR</sub> outperformed both I<sub>FULL</sub> and I<sub>ZERO</sub> in terms of force and power. Coaches and therapists are advised to consider variable inertial profiles as a key parameter when designing exercise programs for athletes or patients.</p>","PeriodicalId":8874,"journal":{"name":"Bioengineering","volume":"12 3","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2025-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11939630/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering12030292","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Strength training machines incorporating advanced electro-mechanical technologies can produce hybrid resistances with variable inertia, such as a resistance that progressively changes from gravitational (inertial) to pneumatic (non-inertial) across the range of motion (ROM). To explore the biomechanical effects of these innovative resistances, a robotic chest press machine was programmed to offer three distinct inertial profiles: gravitational-type constant inertia throughout the ROM (IFULL); no inertia (IZERO); and linearly descending inertia across the ROM (IVAR). Ten healthy adults performed five maximal-effort, explosive chest press movements under each inertial profile at 30, 50 and 70% of their one-repetition maximum. During each trial, muscle activity of the pectoralis major, anterior deltoid, and triceps brachii was recorded, along with force, velocity and power outputs from the machine. Statistical non-parametric maps based on two-way repeated measures ANOVA were used to assess the effects of load level and inertial profile on the collected time series. Higher load levels consistently led to increased force and reduced velocity and power outcomes over large parts of the ROM. Compared to IFULL, IZERO allowed for greater velocity at the expense of lower force throughout the ROM, while IVAR produced higher force and power outputs despite having lower velocity than IZERO. Additionally, both IZERO and IVAR significantly increased triceps brachii activity at the end of the ROM compared to IFULL. IVAR outperformed both IFULL and IZERO in terms of force and power. Coaches and therapists are advised to consider variable inertial profiles as a key parameter when designing exercise programs for athletes or patients.

采用先进电子机械技术的力量训练机可以产生具有可变惯性的混合阻力,例如在整个运动范围(ROM)内从重力(惯性)到气动(非惯性)逐渐变化的阻力。为了探索这些创新阻力的生物力学效应,我们对机器人胸外按压机进行了编程,以提供三种不同的惯性曲线:在整个运动范围内具有重力型恒定惯性(IFULL);无惯性(IZERO);以及在整个运动范围内具有线性下降惯性(IVAR)。10 名健康成年人在每种惯性情况下分别以 30%、50% 和 70% 的单次重复最大值进行了 5 次最大用力、爆发力胸部下压动作。在每次试验期间,记录胸大肌、三角肌前部和肱三头肌的肌肉活动,以及机器输出的力量、速度和功率。基于双向重复测量方差分析的非参数统计图表用于评估负荷水平和惯性曲线对所收集的时间序列的影响。负荷水平越高,力越大,速度和功率结果越小。与 IFULL 相比,IZERO 允许在整个 ROM 中以较低的力量为代价获得更大的速度,而 IVAR 尽管速度低于 IZERO,但却产生了更高的力量和功率输出。此外,与 IFULL 相比,IZERO 和 IVAR 都显著增加了肱三头肌在 ROM 结束时的活动量。在力量和功率方面,IVAR优于IFULL和IZERO。建议教练和治疗师在为运动员或患者设计锻炼计划时,将可变惯性曲线作为一个关键参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Bioengineering
Bioengineering Chemical Engineering-Bioengineering
CiteScore
4.00
自引率
8.70%
发文量
661
期刊介绍: Aims Bioengineering (ISSN 2306-5354) provides an advanced forum for the science and technology of bioengineering. It publishes original research papers, comprehensive reviews, communications and case reports. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. All aspects of bioengineering are welcomed from theoretical concepts to education and applications. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, four key features of this Journal: ● We are introducing a new concept in scientific and technical publications “The Translational Case Report in Bioengineering”. It is a descriptive explanatory analysis of a transformative or translational event. Understanding that the goal of bioengineering scholarship is to advance towards a transformative or clinical solution to an identified transformative/clinical need, the translational case report is used to explore causation in order to find underlying principles that may guide other similar transformative/translational undertakings. ● Manuscripts regarding research proposals and research ideas will be particularly welcomed. ● Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material. ● We also accept manuscripts communicating to a broader audience with regard to research projects financed with public funds. Scope ● Bionics and biological cybernetics: implantology; bio–abio interfaces ● Bioelectronics: wearable electronics; implantable electronics; “more than Moore” electronics; bioelectronics devices ● Bioprocess and biosystems engineering and applications: bioprocess design; biocatalysis; bioseparation and bioreactors; bioinformatics; bioenergy; etc. ● Biomolecular, cellular and tissue engineering and applications: tissue engineering; chromosome engineering; embryo engineering; cellular, molecular and synthetic biology; metabolic engineering; bio-nanotechnology; micro/nano technologies; genetic engineering; transgenic technology ● Biomedical engineering and applications: biomechatronics; biomedical electronics; biomechanics; biomaterials; biomimetics; biomedical diagnostics; biomedical therapy; biomedical devices; sensors and circuits; biomedical imaging and medical information systems; implants and regenerative medicine; neurotechnology; clinical engineering; rehabilitation engineering ● Biochemical engineering and applications: metabolic pathway engineering; modeling and simulation ● Translational bioengineering
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信