Co/Zn ZIFs with MXene and MWCNTs nanocomposites for electro-detection of nitrite ions: Effect of composite substrate

IF 2.5 Q2 CHEMISTRY, MULTIDISCIPLINARY
Biuck Habibi, Samaneh Makani, Rahim Mohammad-Rezaei
{"title":"Co/Zn ZIFs with MXene and MWCNTs nanocomposites for electro-detection of nitrite ions: Effect of composite substrate","authors":"Biuck Habibi,&nbsp;Samaneh Makani,&nbsp;Rahim Mohammad-Rezaei","doi":"10.1016/j.rechem.2025.102215","DOIUrl":null,"url":null,"abstract":"<div><div>This work introduces an electrochemical sensor designed for detection of nitrite ions using multi walled carbon nanotubes bimetallic zeolitic imidazole frameworks (MWCNTs-Co/Zn ZIFs) and MXene-Co/Zn ZIFs modified carbon ceramic electrodes (CCE) through a one-step electrochemical process. The pHysiochemical characterizations of modified electrodes were investigated by using X-ray powder diffraction, Fourier transform infrared spectroscopy, scanning electron microscope, energy dispersive X-ray and electrochemical methods. Cyclic voltammetry and chronoamperometry techniques were used to assess the electrochemical performance of the modified electrodes toward oxidation and determination of nitrite ions. Both of the MWCNTs-Co/Zn ZIFs/CCE and MXene-Co/Zn ZIFs/CCE show high electrocatalytic activity for oxidation of nitrite ions in neutral media (pH = 7.0). Owing to the fascinating synergy between the intrinsic two-dimensional MXene and Co/Zn-ZIFs, the MXene-Co/Zn-ZIFs/CCE shows better electrocatalytic activity than the MWCNTs-Co/Zn ZIFs/CCE. The selected sensor, MXene-Co/Zn ZIFs/CCE, exhibits a linear response range from 2 to 500 μM, LOD (1.6 μM), LOQ (5.5 μM) and sensitivity (1.80180 μA mM<sup>−1</sup> cm<sup>−2</sup>). Moreover, this sensor retains 96.77 % of its initial response after 25 days of storage at room temperature in the laboratory. Finally, the MXene-Co/Zn ZIFs/CCE was used for determination of nitrite ions in real samples with satisfactory results which suggests that the constructed sensor has high potential application in food samples analysis.</div></div>","PeriodicalId":420,"journal":{"name":"Results in Chemistry","volume":"15 ","pages":"Article 102215"},"PeriodicalIF":2.5000,"publicationDate":"2025-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Results in Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2211715625001985","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

This work introduces an electrochemical sensor designed for detection of nitrite ions using multi walled carbon nanotubes bimetallic zeolitic imidazole frameworks (MWCNTs-Co/Zn ZIFs) and MXene-Co/Zn ZIFs modified carbon ceramic electrodes (CCE) through a one-step electrochemical process. The pHysiochemical characterizations of modified electrodes were investigated by using X-ray powder diffraction, Fourier transform infrared spectroscopy, scanning electron microscope, energy dispersive X-ray and electrochemical methods. Cyclic voltammetry and chronoamperometry techniques were used to assess the electrochemical performance of the modified electrodes toward oxidation and determination of nitrite ions. Both of the MWCNTs-Co/Zn ZIFs/CCE and MXene-Co/Zn ZIFs/CCE show high electrocatalytic activity for oxidation of nitrite ions in neutral media (pH = 7.0). Owing to the fascinating synergy between the intrinsic two-dimensional MXene and Co/Zn-ZIFs, the MXene-Co/Zn-ZIFs/CCE shows better electrocatalytic activity than the MWCNTs-Co/Zn ZIFs/CCE. The selected sensor, MXene-Co/Zn ZIFs/CCE, exhibits a linear response range from 2 to 500 μM, LOD (1.6 μM), LOQ (5.5 μM) and sensitivity (1.80180 μA mM−1 cm−2). Moreover, this sensor retains 96.77 % of its initial response after 25 days of storage at room temperature in the laboratory. Finally, the MXene-Co/Zn ZIFs/CCE was used for determination of nitrite ions in real samples with satisfactory results which suggests that the constructed sensor has high potential application in food samples analysis.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Results in Chemistry
Results in Chemistry Chemistry-Chemistry (all)
CiteScore
2.70
自引率
8.70%
发文量
380
审稿时长
56 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信