The Impact of a Tongue Training Device on Tongue Muscle Strength in Patients with Obstructive Sleep Apnea After Modified Uvulopalatopharyngoplasty: A Pilot Study.

IF 2.4 4区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Yung-An Tsou, Chien-Hao Huang, Yu-Jen Chou, Hsueh-Hsin Kao, Jui-Kun Chiang, Yee-Hsin Kao
{"title":"The Impact of a Tongue Training Device on Tongue Muscle Strength in Patients with Obstructive Sleep Apnea After Modified Uvulopalatopharyngoplasty: A Pilot Study.","authors":"Yung-An Tsou, Chien-Hao Huang, Yu-Jen Chou, Hsueh-Hsin Kao, Jui-Kun Chiang, Yee-Hsin Kao","doi":"10.3390/medicina61030511","DOIUrl":null,"url":null,"abstract":"<p><p><i>Background and Objectives</i>: Sufficient evidence supports the Iowa Oral Performance Instrument (IOPI) as a reliable tool for measuring tongue strength and endurance as well as an effective assessment instrument for intervention studies. This study aimed to investigate the impact of a tongue training device, the HEAL, on tongue muscle strength in patients with obstructive sleep apnea (OSA) following modified uvulopalatopharyngoplasty (UPPP), utilizing the IOPI for evaluation. <i>Materials and Methods</i>: We introduced a tongue strengthener, the HEAL, made from medical-grade silicone, designed to improve tongue strength. Each patient was provided with the HEAL and instructed to begin using it one month after undergoing modified UPPP for OSA. The tongue strength of OSA patients was measured using the IOPI both before using the HEAL and approximately 6 weeks later. <i>Results</i>: A total of 66 participants with OSA underwent modified UPPP and were included in the final analysis. The mean age was 39.15 ± 8.84 years, and the mean BMI was 27.41 ± 4.03 kg/m<sup>2</sup>. The duration between the pre- and post-assessment of tongue strength using the HEAL was 42.95 ± 17.97 days. The mean tongue strength pressure before and after using the HEAL was 32.16 ± 16.00 kilopascals (kPa) and 42.95 ± 17.97 kPa, respectively. Tongue strength increased by an average of approximately 52.8% after using the HEAL for an approximate duration of 6 weeks. <i>Conclusions</i>: In the current study, participants with OSA who had undergone modified UPPP and subsequently used the HEAL demonstrated an average improvement of 10.79 kPa in tongue strength-an increase of over 50%-as measured by the IOPI. The interval between the pre- and post-assessment of tongue strength was approximately six weeks. Further studies are needed to validate these findings.</p>","PeriodicalId":49830,"journal":{"name":"Medicina-Lithuania","volume":"61 3","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11943516/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicina-Lithuania","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/medicina61030511","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background and Objectives: Sufficient evidence supports the Iowa Oral Performance Instrument (IOPI) as a reliable tool for measuring tongue strength and endurance as well as an effective assessment instrument for intervention studies. This study aimed to investigate the impact of a tongue training device, the HEAL, on tongue muscle strength in patients with obstructive sleep apnea (OSA) following modified uvulopalatopharyngoplasty (UPPP), utilizing the IOPI for evaluation. Materials and Methods: We introduced a tongue strengthener, the HEAL, made from medical-grade silicone, designed to improve tongue strength. Each patient was provided with the HEAL and instructed to begin using it one month after undergoing modified UPPP for OSA. The tongue strength of OSA patients was measured using the IOPI both before using the HEAL and approximately 6 weeks later. Results: A total of 66 participants with OSA underwent modified UPPP and were included in the final analysis. The mean age was 39.15 ± 8.84 years, and the mean BMI was 27.41 ± 4.03 kg/m2. The duration between the pre- and post-assessment of tongue strength using the HEAL was 42.95 ± 17.97 days. The mean tongue strength pressure before and after using the HEAL was 32.16 ± 16.00 kilopascals (kPa) and 42.95 ± 17.97 kPa, respectively. Tongue strength increased by an average of approximately 52.8% after using the HEAL for an approximate duration of 6 weeks. Conclusions: In the current study, participants with OSA who had undergone modified UPPP and subsequently used the HEAL demonstrated an average improvement of 10.79 kPa in tongue strength-an increase of over 50%-as measured by the IOPI. The interval between the pre- and post-assessment of tongue strength was approximately six weeks. Further studies are needed to validate these findings.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Medicina-Lithuania
Medicina-Lithuania 医学-医学:内科
CiteScore
3.30
自引率
3.80%
发文量
1578
审稿时长
25.04 days
期刊介绍: The journal’s main focus is on reviews as well as clinical and experimental investigations. The journal aims to advance knowledge related to problems in medicine in developing countries as well as developed economies, to disseminate research on global health, and to promote and foster prevention and treatment of diseases worldwide. MEDICINA publications cater to clinicians, diagnosticians and researchers, and serve as a forum to discuss the current status of health-related matters and their impact on a global and local scale.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信