ECMO Support in Pediatric Populations with the Newborn ECMOLife Centrifugal Pump.

IF 2.4 4区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Carlo Pace Napoleone, Ignazio Condello, Maria Teresa Cascarano, Enrico Aidala, Licia Peruzzi, Isabella Molinari, Cristina Rivoldini, Maria Stella Di Carlo, Stefania Iannandrea, Enrico Bonaveglio
{"title":"ECMO Support in Pediatric Populations with the Newborn ECMOLife Centrifugal Pump.","authors":"Carlo Pace Napoleone, Ignazio Condello, Maria Teresa Cascarano, Enrico Aidala, Licia Peruzzi, Isabella Molinari, Cristina Rivoldini, Maria Stella Di Carlo, Stefania Iannandrea, Enrico Bonaveglio","doi":"10.3390/medicina61030493","DOIUrl":null,"url":null,"abstract":"<p><p><i>Background and Objectives</i>: Pediatric ECMO is a valid support mechanism for refractory cardiac and/or respiratory failure. Magnetic levitation technology applied to the centrifugal pump has reduced the hemolysis caused by this procedure, which can be particularly dangerous, especially in neonates and small children. ECMOLife, a new magnetic levitation centrifugal pump, has been introduced for these patients. <i>Materials and Methods</i>: Four patients were supported with the ECMOLife System in a newborn setting, with veno-venous application in two cases and veno-arterial in the other two. All parameters related to pump functioning, anticoagulation, hemolysis, and inflammation were recorded for the duration of the support. <i>Results</i>: All patients survived the procedure, in three cases achieving recovery, while one veno-arterial ECMO was switched to VAD, and then the patient underwent heart transplantation. All recorded parameters were compatible with clinical conditions. In particular, free haemoglobin was close to 0 g/L in all recorded samples. The possibility of monitoring pump functioning parameters, venous and arterial O2 saturation, and venous and arterial pressures creates an opportunity to check the adequacy of mechanical support for the clinical condition of the patient. <i>Conclusions</i>: This is the first reported experiment in a newborn setting with ECMOLife mechanical support. At present, ECMOLife represents the only system with a newborn and pediatric pump, allowing for the continuous monitoring of perfusion and hemodynamic parameters, with a large number of facilities for transportation available.</p>","PeriodicalId":49830,"journal":{"name":"Medicina-Lithuania","volume":"61 3","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11943931/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicina-Lithuania","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/medicina61030493","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background and Objectives: Pediatric ECMO is a valid support mechanism for refractory cardiac and/or respiratory failure. Magnetic levitation technology applied to the centrifugal pump has reduced the hemolysis caused by this procedure, which can be particularly dangerous, especially in neonates and small children. ECMOLife, a new magnetic levitation centrifugal pump, has been introduced for these patients. Materials and Methods: Four patients were supported with the ECMOLife System in a newborn setting, with veno-venous application in two cases and veno-arterial in the other two. All parameters related to pump functioning, anticoagulation, hemolysis, and inflammation were recorded for the duration of the support. Results: All patients survived the procedure, in three cases achieving recovery, while one veno-arterial ECMO was switched to VAD, and then the patient underwent heart transplantation. All recorded parameters were compatible with clinical conditions. In particular, free haemoglobin was close to 0 g/L in all recorded samples. The possibility of monitoring pump functioning parameters, venous and arterial O2 saturation, and venous and arterial pressures creates an opportunity to check the adequacy of mechanical support for the clinical condition of the patient. Conclusions: This is the first reported experiment in a newborn setting with ECMOLife mechanical support. At present, ECMOLife represents the only system with a newborn and pediatric pump, allowing for the continuous monitoring of perfusion and hemodynamic parameters, with a large number of facilities for transportation available.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Medicina-Lithuania
Medicina-Lithuania 医学-医学:内科
CiteScore
3.30
自引率
3.80%
发文量
1578
审稿时长
25.04 days
期刊介绍: The journal’s main focus is on reviews as well as clinical and experimental investigations. The journal aims to advance knowledge related to problems in medicine in developing countries as well as developed economies, to disseminate research on global health, and to promote and foster prevention and treatment of diseases worldwide. MEDICINA publications cater to clinicians, diagnosticians and researchers, and serve as a forum to discuss the current status of health-related matters and their impact on a global and local scale.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信