Mirela Crihan, Alexandru Leonard Alexa, Dan Valean, Daniela Ionescu
{"title":"Continuous Non-Invasive Hemodynamic Monitoring in Cirrhotic Patients-Friend or Foe?","authors":"Mirela Crihan, Alexandru Leonard Alexa, Dan Valean, Daniela Ionescu","doi":"10.3390/medicina61030536","DOIUrl":null,"url":null,"abstract":"<p><p><i>Background and Objectives</i>: Liver cirrhosis leads to significant hemodynamic changes, particularly portal hypertension and a hyperdynamic circulatory state. Traditional invasive methods for hemodynamic monitoring, while accurate, carry risks such as infection and hemorrhage in a patient predisposed to these conditions. This study evaluates the accuracy of non-invasive continuous hemodynamic monitoring compared to a minimally invasive method in patients with decompensated liver cirrhosis. <i>Materials and Materials and Methods</i>: The study enrolled 51 patients with decompensated liver cirrhosis requiring continuous hemodynamic monitoring in the ICU. Patients underwent simultaneous monitoring via the minimally invasive FloTrac system and continuous non-invasive ClearSight sensor over 24 h, with measurements registered at 6 h intervals. Hemodynamic parameters measured included cardiac output (CO), cardiac index (CI), stroke volume (SV), stroke volume variation (SVV), systemic vascular resistance (SVR), and mean arterial pressure (MAP). <i>Results</i>: Significant discrepancies were observed between the two monitoring methods for most parameters, particularly CO, CI, and MAP, at most time intervals. However, SVV measurements showed no significant differences, indicating similar efficacy in assessing fluid responsiveness between the devices. <i>Conclusions</i>: The ClearSight system, although a valuable non-invasive alternative, demonstrated lower accuracy compared to the FloTrac system for hemodynamic measurements in patients with decompensated liver cirrhosis. Its effectiveness in assessing fluid responsiveness, particularly by SVV, suggests it could play a role in the monitoring of these patients, especially when invasive techniques have increased risks.</p>","PeriodicalId":49830,"journal":{"name":"Medicina-Lithuania","volume":"61 3","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11943466/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicina-Lithuania","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/medicina61030536","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background and Objectives: Liver cirrhosis leads to significant hemodynamic changes, particularly portal hypertension and a hyperdynamic circulatory state. Traditional invasive methods for hemodynamic monitoring, while accurate, carry risks such as infection and hemorrhage in a patient predisposed to these conditions. This study evaluates the accuracy of non-invasive continuous hemodynamic monitoring compared to a minimally invasive method in patients with decompensated liver cirrhosis. Materials and Materials and Methods: The study enrolled 51 patients with decompensated liver cirrhosis requiring continuous hemodynamic monitoring in the ICU. Patients underwent simultaneous monitoring via the minimally invasive FloTrac system and continuous non-invasive ClearSight sensor over 24 h, with measurements registered at 6 h intervals. Hemodynamic parameters measured included cardiac output (CO), cardiac index (CI), stroke volume (SV), stroke volume variation (SVV), systemic vascular resistance (SVR), and mean arterial pressure (MAP). Results: Significant discrepancies were observed between the two monitoring methods for most parameters, particularly CO, CI, and MAP, at most time intervals. However, SVV measurements showed no significant differences, indicating similar efficacy in assessing fluid responsiveness between the devices. Conclusions: The ClearSight system, although a valuable non-invasive alternative, demonstrated lower accuracy compared to the FloTrac system for hemodynamic measurements in patients with decompensated liver cirrhosis. Its effectiveness in assessing fluid responsiveness, particularly by SVV, suggests it could play a role in the monitoring of these patients, especially when invasive techniques have increased risks.
期刊介绍:
The journal’s main focus is on reviews as well as clinical and experimental investigations. The journal aims to advance knowledge related to problems in medicine in developing countries as well as developed economies, to disseminate research on global health, and to promote and foster prevention and treatment of diseases worldwide. MEDICINA publications cater to clinicians, diagnosticians and researchers, and serve as a forum to discuss the current status of health-related matters and their impact on a global and local scale.