{"title":"Design of Temperature Monitoring and Fault Warning System for Lithium Ternary Battery Case.","authors":"Xiyao Liu, Kuihua Han","doi":"10.3390/mi16030345","DOIUrl":null,"url":null,"abstract":"<p><p>To enhance the safety of lithium ternary battery cases in new energy vehicles, this study designed a temperature monitoring and fault warning system based on NiCr/NiSi thin-film thermocouples. The system integrates six modules-sensor, amplifier, data acquisition, microprocessor (using the KPCA nonlinear dimensionality reduction algorithm), communication and monitoring, and alarm control-to monitor temperature, voltage, and humidity changes in real time. Multi-level warning thresholds are established (e.g., Level 1: initial temperature 35-55 °C rising to 42-65 °C after 10 min; initial voltage 400-425 V dropping to 398-375 V after 10 min). Experimental results demonstrate that the NiCr/NiSi thermocouple exhibits high sensitivity (average Seebeck coefficient: 41.42 μV/°C) and low repeatability error (1.04%), with a dense and uniform surface structure (roughness: 3.2-5.75 nm). The warning logic, triggered in four levels based on dynamic temperature and voltage changes, achieves an 80% accuracy rate and a low false/missed alarm rate of 4%. Long-term operation tests show stable monitoring deviations (±0.2 °C for temperature and ±0.02 V for voltage over 24 h). The system also adapts to varying humidity environments, with peak sensitivity (41.3 μV/°C) at 60% RH. This research provides a highly reliable solution for battery safety management in new energy vehicles.</p>","PeriodicalId":18508,"journal":{"name":"Micromachines","volume":"16 3","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11946480/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micromachines","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/mi16030345","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
To enhance the safety of lithium ternary battery cases in new energy vehicles, this study designed a temperature monitoring and fault warning system based on NiCr/NiSi thin-film thermocouples. The system integrates six modules-sensor, amplifier, data acquisition, microprocessor (using the KPCA nonlinear dimensionality reduction algorithm), communication and monitoring, and alarm control-to monitor temperature, voltage, and humidity changes in real time. Multi-level warning thresholds are established (e.g., Level 1: initial temperature 35-55 °C rising to 42-65 °C after 10 min; initial voltage 400-425 V dropping to 398-375 V after 10 min). Experimental results demonstrate that the NiCr/NiSi thermocouple exhibits high sensitivity (average Seebeck coefficient: 41.42 μV/°C) and low repeatability error (1.04%), with a dense and uniform surface structure (roughness: 3.2-5.75 nm). The warning logic, triggered in four levels based on dynamic temperature and voltage changes, achieves an 80% accuracy rate and a low false/missed alarm rate of 4%. Long-term operation tests show stable monitoring deviations (±0.2 °C for temperature and ±0.02 V for voltage over 24 h). The system also adapts to varying humidity environments, with peak sensitivity (41.3 μV/°C) at 60% RH. This research provides a highly reliable solution for battery safety management in new energy vehicles.
期刊介绍:
Micromachines (ISSN 2072-666X) is an international, peer-reviewed open access journal which provides an advanced forum for studies related to micro-scaled machines and micromachinery. It publishes reviews, regular research papers and short communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.