Cyclic Fatigue, Torsional Strength and Angular Deflection of Different Reciprocating Instruments: A Critical Analysis of Its Clinical Relevance.

IF 1.6 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Javier Caviedes Bucheli, Abel Teves Cordova, Murilo Priori Alcalde, Hugo Roberto Munoz, Hernan Dario Muñoz Alvear, Monique Marie Gay, Ricardo Portigliatti, Jose Francisco Gomez Sosa, Jorge Olmos Fassi, Marco Antonio Hungaro Duarte
{"title":"Cyclic Fatigue, Torsional Strength and Angular Deflection of Different Reciprocating Instruments: A Critical Analysis of Its Clinical Relevance.","authors":"Javier Caviedes Bucheli, Abel Teves Cordova, Murilo Priori Alcalde, Hugo Roberto Munoz, Hernan Dario Muñoz Alvear, Monique Marie Gay, Ricardo Portigliatti, Jose Francisco Gomez Sosa, Jorge Olmos Fassi, Marco Antonio Hungaro Duarte","doi":"10.14744/eej.2024.08860","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the cyclic fatigue fracture resistance, torsional fatigue, and angular deflection of Reciproc Blue (RB), WaveOne Gold (WOG), One Reci (OR), and Plex RC-One (RC-One) instruments for managing root curvatures in simulated canals.</p><p><strong>Methods: </strong>A sample size calculation determined 10 samples per group (5 instruments for the cyclic fatigue test and 5 for the torsional fatigue test) for detecting significant differences. The study included 40 NiTi instruments (25 mm) from four reciprocating systems groups: RB R25, WOG 25, OR 25, and RC-One 25. Instruments were inspected for defects. Bending tests assessed memory control. Static cyclic fatigue tests used an artificial 60° curved canal with motorized activation. Torsional fatigue followed ISO 3630-1, measuring torque and angular deflection until failure. Fractured surfaces were analyzed using automated image analysis and measured with Rhinoceros 8.0 software. Statistical analysis included central tendency and dispersion measures, followed by ANOVA to identify statistically significant differences between groups.</p><p><strong>Results: </strong>The bending test showed RC-One retained shape after pressure, while RB exhibited moderate resistance. WOG and OR did not demonstrate satisfactory bending resistance. Analysis of cyclic fatigue revealed RC-One had the highest resistance, followed by RB, OR, and WOG (p<0.001). RB required the highest torque for fracture, followed by RC-One, WOG, and OR (p<0.001). WOG had the lowest deflection angle at fracture, followed by OR, RB, and RC-One (p=0.0399). SEM and intelligent automated image processing analysis showed RC-One and RB had wear zones indicative of slow fracture, while WOG and OR displayed 100% rapid fracture dimples. RC-One had 41.86% slow fracture and 54.14% rapid fracture, while RB had 17.83% slow and 82.17% rapid fracture. Torsion tests revealed similar features in RC-One and RB, supporting their high and similar torsional resistance and deflection, unlike WOG's lower resistance and OR's lowest resistance with the highest deflection.</p><p><strong>Conclusion: </strong>The best performance in the bending test was obtained by RC-One, followed by RB, while most failures were observed in WOG and OR. RC-One showed significantly higher cyclic fatigue resistance in severe curvatures than RB, WOG, and OR. RB and RC-One exhibited very similar torsional resistance values, significantly higher than OR and WOG. RC-One displayed superior angular deflection results compared to the other instruments. (EEJ-2024-08-135).</p>","PeriodicalId":11860,"journal":{"name":"European Endodontic Journal","volume":"10 2","pages":"159-172"},"PeriodicalIF":1.6000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11971697/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Endodontic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14744/eej.2024.08860","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the cyclic fatigue fracture resistance, torsional fatigue, and angular deflection of Reciproc Blue (RB), WaveOne Gold (WOG), One Reci (OR), and Plex RC-One (RC-One) instruments for managing root curvatures in simulated canals.

Methods: A sample size calculation determined 10 samples per group (5 instruments for the cyclic fatigue test and 5 for the torsional fatigue test) for detecting significant differences. The study included 40 NiTi instruments (25 mm) from four reciprocating systems groups: RB R25, WOG 25, OR 25, and RC-One 25. Instruments were inspected for defects. Bending tests assessed memory control. Static cyclic fatigue tests used an artificial 60° curved canal with motorized activation. Torsional fatigue followed ISO 3630-1, measuring torque and angular deflection until failure. Fractured surfaces were analyzed using automated image analysis and measured with Rhinoceros 8.0 software. Statistical analysis included central tendency and dispersion measures, followed by ANOVA to identify statistically significant differences between groups.

Results: The bending test showed RC-One retained shape after pressure, while RB exhibited moderate resistance. WOG and OR did not demonstrate satisfactory bending resistance. Analysis of cyclic fatigue revealed RC-One had the highest resistance, followed by RB, OR, and WOG (p<0.001). RB required the highest torque for fracture, followed by RC-One, WOG, and OR (p<0.001). WOG had the lowest deflection angle at fracture, followed by OR, RB, and RC-One (p=0.0399). SEM and intelligent automated image processing analysis showed RC-One and RB had wear zones indicative of slow fracture, while WOG and OR displayed 100% rapid fracture dimples. RC-One had 41.86% slow fracture and 54.14% rapid fracture, while RB had 17.83% slow and 82.17% rapid fracture. Torsion tests revealed similar features in RC-One and RB, supporting their high and similar torsional resistance and deflection, unlike WOG's lower resistance and OR's lowest resistance with the highest deflection.

Conclusion: The best performance in the bending test was obtained by RC-One, followed by RB, while most failures were observed in WOG and OR. RC-One showed significantly higher cyclic fatigue resistance in severe curvatures than RB, WOG, and OR. RB and RC-One exhibited very similar torsional resistance values, significantly higher than OR and WOG. RC-One displayed superior angular deflection results compared to the other instruments. (EEJ-2024-08-135).

不同往复器械的循环疲劳、扭转强度和角偏转:临床相关性的关键分析。
目的:评价Reciproc Blue (RB)、WaveOne Gold (WOG)、One Reci (OR)和Plex RC-One (RC-One)器械在处理模拟根管弯曲时的抗循环疲劳断裂性、扭转疲劳性和角挠度。方法:通过样本量计算,确定每组10个样本(循环疲劳试验5个,扭转疲劳试验5个),以检测显著性差异。该研究包括40个NiTi仪器(25毫米),来自四个往复系统组:RB R25、WOG 25、OR 25和RC-One 25。检查仪器是否有缺陷。弯曲测试评估记忆控制。静态循环疲劳试验采用电动激活的人工60°弯曲管。扭转疲劳遵循ISO 3630-1,测量扭矩和角偏转直到失效。采用自动图像分析和Rhinoceros 8.0软件测量断裂表面。统计分析包括集中趋势和离散度测量,随后采用方差分析来确定组间的统计学显著差异。结果:弯曲试验显示RC-One受压后仍保持形状,而RB表现出中等的阻力。WOG和OR的抗弯性能不理想。循环疲劳分析表明RC-One的抗疲劳性能最高,其次是RB、OR和WOG (p)。结论:RC-One在弯曲试验中性能最好,RB次之,WOG和OR失效最多。RC-One在剧烈曲率下的抗循环疲劳性能明显高于RB、WOG和OR。RB和RC-One表现出非常相似的扭转抗力值,显著高于OR和WOG。与其他仪器相比,RC-One显示出优越的角偏转结果。(eej - 2024 - 08 - 135)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
European Endodontic Journal
European Endodontic Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.40
自引率
5.60%
发文量
25
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信